125424 SPX350A1-4A4N1

Variable frequency drive, 400 V AC, 3-phase, 250 kW, IP21, Radio interference suppression filter, OLED display, FR10
Variable frequency drive, Part group reference (e.g. DIL): SPX, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 460 A, Rated operational current At 110% overload: Ie = 520 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: For AC motors with internal and external ventilation with 50 Hz / 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 250 kW, 110 % Overload: P = 250 kW, 150 % Overload: IM = 437 A, 110 % Overload: IM = 437 A, Assigned motor rating Note: at 440 - 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 350 HP, 110 % Overload: P = 350 HP, Assigned motor rating 150 % Overload: IM = 414 A, 110 % Overload: IM = 414 A, Degree of Protection: IP21, Fieldbus connection (optional): PROFIBUS-DP, LonWorks, CANopen®, DeviceNet, Modbus-TCP, BACnet/IP, Fitted with: Radio interference suppression filter, OLED display, DC link choke, Frame size: FR10, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Ürün Açıklaması

Variable frequency drive, 400 V AC, 3-phase, 250 kW, IP21, Radio interference suppression filter, OLED display, FR10
Variable frequency drive, Part group reference (e.g. DIL): SPX, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 460 A, Rated operational current At 110% overload: Ie = 520 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: For AC motors with internal and external ventilation with 50 Hz / 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 250 kW, 110 % Overload: P = 250 kW, 150 % Overload: IM = 437 A, 110 % Overload: IM = 437 A, Assigned motor rating Note: at 440 - 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 350 HP, 110 % Overload: P = 350 HP, Assigned motor rating 150 % Overload: IM = 414 A, 110 % Overload: IM = 414 A, Degree of Protection: IP21, Fieldbus connection (optional): PROFIBUS-DP, LonWorks, CANopen®, DeviceNet, Modbus-TCP, BACnet/IP, Fitted with: Radio interference suppression filter, OLED display, DC link choke, Frame size: FR10, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1
Product range Variable frequency drives
Part group reference (e.g. DIL) SPX
Rated operational voltage [Ue] 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Output voltage with Ve [U2] 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Mains voltage (50/60Hz) [ULN] 380 (-15%) - 500 (+10%) V
At 150% overload [Ie]
At 110% overload [Ie] 460 A
Note 520 A
Note
Note For AC motors with internal and external ventilation with 50 Hz / 60 Hz
150 % Overload [P] Overload cycle for 60 s every 600 s
110 % Overload [P] at 400 V, 50 Hz
150 % Overload [IM] 250 kW
110 % Overload [IM] 250 kW
Note 437 A
150 % Overload [P] 437 A
110 % Overload [P] at 440 - 480 V, 60 Hz
150 % Overload [IM] 350 HP
110 % Overload [IM] 350 HP
Degree of Protection 414 A
Fieldbus connection (optional) 414 A
Fitted with IP21
Frame size PROFIBUS-DP
PROFINET
EtherCAT
EtherNet/IP
LonWorks
CANopen®
DeviceNet
Modbus-TCP
Modbus-RTU
BACnet MS/TP
Connection to SmartWire-DT Radio interference suppression filter
OLED display
Standards FR10
Certifications no
Approvals
Production quality Specification for general requirements: IEC/EN 61800-2
EMC requirements: IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5-1
Climatic proofing [ρw] CE, UL, cUL, RCM
Ambient temperature
>Operating ambient temperature min.
DNV
Ambient temperature
>Operating ambient temperature max.
RoHS, ISO 9001
Ambient temperature
>operation (110 % overload) [ϑ]
< 95% relative humidity, no condensation, no corrosion, no dripping water %
Ambient temperature
>Storage [ϑ]
-10 °C
Radio interference level
>Radio interference class (EMC)
+50 °C
Radio interference level
>Environment (EMC)
-10 - +40 °C
Mounting position -40 - +70 °C
Altitude C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Degree of Protection 1st and 2nd environments as per EN 61800-3
Protection against direct contact Vertical
Supply
>Rated operational voltage [Ue]
0 - 1000 m above sea level
above 1000 m with 1 % performance reduction per 100 m
max. 3000 m m
Supply
>Mains voltage (50/60Hz) [ULN]
IP21
Supply
>System configuration
BGV A3 (VBG4, finger- and back-of-hand proof)
Supply
>Supply frequency [fLN]
Supply
>Frequency range [fLN]
400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Power section
>Function
380 (-15%) - 500 (+10%) V
Power section
>Output voltage with Ve [U2]
AC supply systems with earthed center point
Power section
>Output Frequency [f2]
50/60 Hz
Power section
>Switching frequency [fPWM]
45–66 (± 0%) Hz
Power section
>Operation Mode
Variable frequency drive with internal DC link and IGBT inverter
Power section
>Frequency resolution (setpoint value) [Δf]
400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Power section
>Rated operational current
>At 150% overload [Ie]
0 - 50/60 (max. 320) Hz
Power section
>Rated operational current
>At 110% overload [Ie]
3.6
adjustable 1 - 6 kHz
Power section
>Fitted with
U/f control
sensorless vector control (SLV)
optional: Vector control with feedback (CLV)
Power section
>Frame size
0.01 Hz
Motor feeder
>Note
460 A
Motor feeder
>Note
520 A
Motor feeder
>Note
Radio interference suppression filter
OLED display
Motor feeder
>150 % Overload [P]
FR10
Motor feeder
>110 % Overload [P]
For AC motors with internal and external ventilation with 50 Hz / 60 Hz
Motor feeder
>Note
Overload cycle for 60 s every 600 s
Motor feeder
>150 % Overload [P]
at 400 V, 50 Hz
Motor feeder
>110 % Overload [P]
250 kW
External control voltage [Uc] 250 kW
Reference voltage [Us] at 440 - 480 V, 60 Hz
Analog inputs 350 HP
Analog outputs 350 HP
Digital inputs
Digital outputs 24 V DC (max. 250 mA) V
Relay outputs 10 V DC (max. 10 mA) V
Motor feeder
>motor choke
>150 % overload (CT/IH, at 50 °C)
2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA
Motor feeder
>motor choke
>110 % overload (VT/IL, at 40 °C)
1, parameterizable, 0/4 - 20 mA
Motor feeder
>Sine filter
>150 % overload (CT/IH, at 50 °C)
6, parameterizable, max. 30 V DC
Motor feeder
>Sine filter
>110 % overload (VT/IL, at 40 °C)
1, parameterizable, 48 V DC/50 mA
Rated operational current for specified heat dissipation [In] 2, parameterizable, N/O, 8 A (24 V DC) / 8 A (250 V AC) / 0,4 A (125 V DC)
Heat dissipation per pole, current-dependent [Pvid]
Equipment heat dissipation, current-dependent [Pvid] DUT-0590-6-0-S
Static heat dissipation, non-current-dependent [Pvs] DUT-0590-6-0-S
Heat dissipation capacity [Pdiss] SIN-0600-5-0-P
Operating ambient temperature min. SIN-0600-5-0-P
Operating ambient temperature max.
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
460 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
6250 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-10 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+50 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Operation (with 150 % overload)
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Mains voltage Is the panel builder´s responsibility.
Mains frequency Is the panel builder´s responsibility.
Number of phases input Is the panel builder´s responsibility.
Number of phases output Is the panel builder´s responsibility.
Max. output frequency Is the panel builder´s responsibility.
Max. output voltage The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Nominal output current I2N Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Max. output at quadratic load at rated output voltage Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Max. output at linear load at rated output voltage The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Relative symmetric net frequency tolerance
Relative symmetric net voltage tolerance
Number of analogue outputs 323 - 550 V
Number of analogue inputs 50/60 Hz
Number of digital outputs 3
Number of digital inputs 3
With control unit 320 Hz
Application in industrial area permitted 500 V
Application in domestic- and commercial area permitted 520 A
Supporting protocol for TCP/IP 250 kW
Supporting protocol for PROFIBUS 250 kW
Supporting protocol for CAN 10 %
Supporting protocol for INTERBUS 10 %
Supporting protocol for ASI 1
Supporting protocol for KNX 2
Supporting protocol for MODBUS 1
Supporting protocol for Data-Highway 6
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET Yes
Supporting protocol for LON Yes
Supporting protocol for PROFINET IO Yes
Supporting protocol for PROFINET CBA Yes
Supporting protocol for SERCOS Yes
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety Yes
Supporting protocol for INTERBUS-Safety Yes
Supporting protocol for PROFIsafe Yes
Supporting protocol for SafetyBUS p No
Supporting protocol for BACnet Yes
Supporting protocol for other bus systems Yes
Number of HW-interfaces industrial Ethernet No
Number of interfaces PROFINET No
Number of HW-interfaces RS-232 No
Number of HW-interfaces RS-422 Yes
Number of HW-interfaces RS-485 No
Number of HW-interfaces serial TTY No
Number of HW-interfaces USB No
Number of HW-interfaces parallel No
Number of HW-interfaces other No
With optical interface No
With PC connection Yes
Integrated breaking resistance 0
4-quadrant operation possible 0
Type of converter 1
Degree of protection (IP) 0
Degree of protection (NEMA) 0
Height 0
Width 0
Depth 0
Product Standards 0
UL File No. No
UL Category Control No. Yes
CSA File No. No
CSA Class No. Yes
North America Certification U converter
Specially designed for North America IP21
Suitable for 1
Max. Voltage Rating 2018 mm
Degree of Protection 595 mm