115974 M22-SWD-K11LED-G

Function element, for combination with RMQ-Titan operating elements M22-..., 1 changeover contact, Front fixing, green
Function element, Fixing: Front fixing, Connection to SmartWire-DT: yes

Ürün Açıklaması

Function element, for combination with RMQ-Titan operating elements M22-..., 1 changeover contact, Front fixing, green
Function element, Fixing: Front fixing, Connection to SmartWire-DT: yes
Basic function accessories Function elements
Function for combination with RMQ-Titan operating elements M22-...
Contacts 1 changeover contact
Fixing Front fixing
Contact sequence 2723SWI-4
Contact travel diagram
stroke in connection with front element
116U024
Configuration 2723SWI-6
Connection to SmartWire-DT 116C059
Standards yes
Approvals
>shipping classification
IEC/EN 61131-2
EN 50178
Dimensions (W x H x D) DNV GL
BV
LRS
Weight 12 x 42 x 45 mm
Mounting position 10 g
Protection type (IEC/EN 60529, EN50178, VBG 4) As required
Vibrations (IEC/EN 61131-2:2008)
>Constant amplitude 3,5 mm
IP20
Vibrations (IEC/EN 61131-2:2008)
>Constant acceleration 1 g
5 - 8.4 Hz
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms 8.4 - 150 Hz
Drop to IEC/EN 60068-2-31 [Drop height] 9 Impacts
Free fall, packaged (IEC/EN 60068-2-32) 50 mm
Overvoltage category 0.3 m
Pollution degree Not applicable
Electrostatic discharge (IEC/EN 61131-2:2008)
>Air discharge (Level 3)
2
Electrostatic discharge (IEC/EN 61131-2:2008)
>Contact discharge (Level 2)
8 kV
Electromagnetic fields (IEC/EN 61131-2:2008)
>80 - 1000 MHz
4 kV
Electromagnetic fields (IEC/EN 61131-2:2008)
>1.4 - 2 GHz
10 V/m
Electromagnetic fields (IEC/EN 61131-2:2008)
>2 - 2.7 GHz
3 V/m
Radio interference suppression (SmartWire-DT) 1 V/m
Burst (IEC/EN 61131-2:2008, Level 3)
>Supply cable
EN 55011 Class A
Burst (IEC/EN 61131-2:2008, Level 3)
>SmartWire-DT cable
2 kV
Radiated RFI (IEC/EN 61131-2:2008, Level 3) 1 kV
Ambient temperature
>Operating ambient temperature (IEC 60068-2)
10 V
Ambient temperature
>Storage
-30 - +70 °C
Relative humidity
>Condensation
- 40 - + 80 °C
Relative humidity
>Relative humidity, non-condensing (IEC/EN 60068-2-30)
Take appropriate measures to prevent condensation
Station type 9 - 95 %
Address allocation SmartWire-DT slave
Status indication automatic
Connections Green LED
Plug connectors Plug, 8-pole
Baud rate setting SWD4-8SF2-5
Switching state display automatic
Diagnostics Yes LED
Fixing Yes
Rated operational current for specified heat dissipation [In] Front fixing
Heat dissipation per pole, current-dependent [Pvid] 0 A
Equipment heat dissipation, current-dependent [Pvid] 0 W
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0.3 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. -30 °C
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
+70 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of contacts as change-over contact The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of contacts as normally open contact 0
Number of contacts as normally closed contact 1
Number of fault-signal switches 1
Rated operation current Ie at AC-15, 230 V 0
Type of electric connection 0 A
Model Flat plug-in connection
Mounting method Top mounting
Lamp holder Front fastening
UL File No. LED not exchangeable
UL Category Control No. E29184
CSA File No. NKCR
CSA Class No. 2324643
North America Certification 3211-07
Specially designed for North America UL listed, CSA certified