106404 EC4P-222-MTAX1

Compact PLC, 24 V DC, 12DI(of 4AI), 8DO(T), 1AO, ethernet, CAN
Compact controller for small and medium-sized automation tasks, programming according to IEC 61131 (CoDeSys), the Ethernet interface and the serial interface (ec4p-222 types) are for the purpose of programming, the communication via UDP and Modbus as well as connection of OPC clients

Ürün Açıklaması

Compact PLC, 24 V DC, 12DI(of 4AI), 8DO(T), 1AO, ethernet, CAN
Compact controller for small and medium-sized automation tasks, programming according to IEC 61131 (CoDeSys), the Ethernet interface and the serial interface (ec4p-222 types) are for the purpose of programming, the communication via UDP and Modbus as well as connection of OPC clients
Description Expandable: Inputs/outputs and bus systems
individual laser inscription possible with EC4-COMBINATION-*
Digital easyNet/CANopen® and Ethernet on board
of which can be used as analog
Transistor 12
Analog 4
Supply voltage
Dimensions (W x H x D) 8
Weight 1
Mounting 24 V DC
Solid
Flexible with ferrule 107.5 x 90 x 72 without/79 with adapter for MCC (6 SU) mm
Standard screwdriver 0.3 kg
Max. tightening torque Top-hat rail IEC/EN 60715, 35 mm or screw fixing using 3 fixing brackets ZB4-101-GF1 (accessories)
Operating ambient temperature
Condensation 0.2/4 (AWG 22 - 12) mm2
LCD display (clearly legible) 0.2/2.5 (AWG 22 - 12) mm2
Storage [ϑ] 0.8 x 3.5 mm
Relative humidity, non-condensing (IEC/EN 60068-2-30) 0.6 Nm
Air pressure (operation)
Protection type (IEC/EN 60529, EN50178, VBG 4) -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C
Vibrations (IEC/EN 60068-2-6)
>Constant amplitude 0.15 mm
Take appropriate measures to prevent condensation
Vibrations (IEC/EN 60068-2-6)
>Constant acceleration 2 g
0 - 55 °C
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms -40 - +70 °C
Drop to IEC/EN 60068-2-31 [Drop height] 5 - 95 %
Free fall, packaged (IEC/EN 60068-2-32) 1080 - 1080 hPa
Mounting position
Overvoltage category/pollution degree IP20
Electrostatic discharge (ESD)
>applied standard
10 - 57 Hz
Electrostatic discharge (ESD)
>Air discharge
57 - 150 Hz
Electrostatic discharge (ESD)
>Contact discharge
18 Impacts
Electromagnetic fields (RFI) to IEC EN 61000-4-3 50 mm
Radio interference suppression 1 m
Burst Vertical or horizontal
Burst
>Supply cable
Burst
>Signal lines
II/2
power pulses (Surge) IEC EN 61000-4-2, Level 3
Immunity to line-conducted interference to (IEC/EN 61000-4-6) 8 kV
Clearance in air and creepage distances 6 kV
Insulation resistance 10 V/m
Back-up of real-time clock EN 55011 Class B, EN 55022 Class B
Accuracy of the real-time clock IEC/EN 61000-4-4, level 3 kV
Write cycles of the retentive memory 2 kV
Rated operational voltage [Ue] 2 kV
Permissible range [Ue] 2 kV (supply cables, symmetrical, EASY...AC)
0.5 kV (supply cables, symmetrical, easy-DC)
according to IEC/EN 61000-4-5
Residual ripple 10 V
Input current
Voltage dips EN 50178, UL 508, CSA C22.2, No. 142
Heat dissipation [P] EN 50178
Processor
Memory
>Program code/data
252U067
Memory
>Marker/retentive data
① Backup time (hours) with fully charged double layer capacitor
② Service life (years)
Cycle time for 1 k of instructions (Bit, Byte) part no. ± 5 (± 0.5 h⁄Year) s/day
PRG interface RS232
>Data transfer rate
PRG interface RS232
>Connection types
10000000000 (10¹⁰) (Read-write cycles)
PRG interface RS232
>Potential isolation
PRG interface RS232
>Master mode
>Data transfer rate
24 DC (-15/+20%) V
PRG interface RS232
>Master mode
>Character formats
20.4 - 28.8 V DC
PRG interface RS232
>Master mode
>Number of transmission bytes in a block
≦ 5 %
PRG interface RS232
>Master mode
>Number of received bytes in a block
normally 140 mA at Ue
Ethernet
>Data transfer rate
≤ 10
(IEC/EN 61131-2) ms
Ethernet
>Connection types
Normally 3.4 W
Ethernet
>Potential isolation
CANopen®
>Data transfer rate
Infineon XC161
CANopen®
>Bus termination (first and last station)
256/14 segments of 16 KB each kByte
CANopen®
>Connection types
16/4/4/8 KByte
Master mode
>Number
< 0.3 ms
Mode slave
>Stations
Mode slave
>PDO type
4.8, 9.6, 19.2, 38.4, 57.6, 115.2 (character format: 8 bit data, no parity, 1 stop bit) kBit/s
Mode slave
>Control contact rated current
RJ45-bus
Number none
Inputs can be used as analog inputs 0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6 kbit/s
Status Display 8E1, 8O1, 8N1, 8N2, 7E2, 7O2, 7N2, 7E1
Potential isolation 190 bytes
Rated operational voltage [Ue] 190 bytes
Input voltage 10 MBit/s, 100 m Mbit/s
Input current on 1 signal
>Input current at signal 1
RJ45
Deceleration time No
Cable length 500 kBit/s, 25 m 250 kBit/s, 60m 125 kBit/s, 125 m 50 kBit/s, 300 m 20 kBit/s, 700 m 10 kBit/s, 1000 m
Incremental counter
>Number of counter inputs
EASY-NT-R plug (incl. bus terminating resistor 120 Ω)
Incremental counter
>Value range
2 x RJ45, 8 pole
Incremental counter
>Counter frequency
8
Incremental counter
>Pulse shape
max. 126 Number
Incremental counter
>Counter inputs
Asynchronous, cyclic, acyclic
Incremental counter
>Reference input
To DS 301 V4
Incremental counter
>Input for reference switch
Incremental counter
>Counter inputs I1 and I2, I3 and I4
12
Incremental counter
>Signal offset
4 (I7, I8, I11, I12)
Rapid counter inputs
>Number
LCD-Display
Rapid counter inputs
>Value range
from the outputs: yes
to network easyNet, easyLink
Rapid counter inputs
>Cable length
24 V DC
Rapid counter inputs
>Counter frequency
< 5 (I1 - I6, I9 - I10) < 8 (I7, I8, I11, I12) at signal "0"
> 15.0 (I1 - I6, I9, I10) > 8.0 (I7, I8, I11, I12) at signal "1" V DC
Rapid counter inputs
>Pulse shape
3.3 (I1 to I6)
2.2 (I7, I8)
3.3 (I9, I10)
2.2 (I11, I12) mA
Number normally 0.02 (I1 - I4), normally 0.25 (I5 - I12) (from ´´0´´ to "1")
normally 0.02 (I1 - I4), normally 0.25 (I5 - I12) (from ´´0´´ to "1") ms
Potential isolation 100 (unshielded) m
Input type 1 (I1, I2, I3, I4)
Signal range 32 Bit
Resolution ≦ 40 kHz
Input impedance Square
Accuracy of actual value
>Within a single device
I1, I2
Conversion time, analog/digital I3
Input current I4
Cable length 1
Number 90°
Output type 2 (I1, I2) at 16 Bit or 1 (I1) at 32 Bit
Max. output current 16/32 Bit
Load resistance ≦ 20 (screened) m
Overload and short-circuit protection ≦ 50 kHz
Resolution Square
Recovery time
Accuracy
>-25 °C - 55 °C
4 (I7, I8, I11, I12)
Accuracy
>25°C
from the outputs: yes
to interface/memory card: no
Conversion time, analog/digital DC voltage
Number 0-10 V DC
Rated operational voltage [Ue] 0.01 V analog
0.01 V digital
10 Bit (value 0 - 1023)
Permissible range [Ue] 11.2 kΩ
Residual ripple ± 2, (I7, I8, I11, I12) ± 0.12 V %
Supply current each CPU cycle ms
Protection against polarity reversal < 1 mA
Potential isolation ≦ 30, screened m
Rated operational current at signal „1” DC per channel [Ie]
Lamp load without Rv per channel 1
Residual current on 0 signal per channel DC voltage
Max. output voltage 0.01 A
Short-circuit protection 1 kΩ
Short-circuit tripping current for Ra ≦ 10 mΩ Yes
Total short-circuit current 0.01 V DC analog
10 Bit (value 0 - 1023) digital
Peak short-circuit current 100 µs
Thermal cutout 2 %
Max. operating frequency with constant resistive load 1 %
Parallel connection of outputs
>With resistive load, inductive load with external suppressor circuit, combination within a group
each CPU cycle ms
Parallel connection of outputs
>Number of outputs [max.]
Parallel connection of outputs
>Max. total current
8
Output status indication 24 V DC
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 1 ms, R = 48 Ω, L = 16 mH
>Utilization factor
20.4 - 28.8 V DC
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 1 ms, R = 48 Ω, L = 16 mH
>Duty factor
5 %
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 1 ms, R = 48 Ω, L = 16 mH
>Max. switching frequency f = 0.5 Hz (max. DF = 50 %)
Norm./max. 18/32 at signal 0
24/44 at signal 1 mA
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H
>Utilization factor
yes (Caution: A short circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.)
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H
>Duty factor
from power supply, inputs
to the memory card: yes
From the inputs: yes
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>DC-13, T0.95 = 72 ms, R = 48 Ω, L = 1.15 H
>Max. switching frequency f = 0.5 Hz (max. DF = 50 %)
Max. 0.5 A
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 15 ms, R = 48 Ω, L = 0.24 H
>Utilization factor
5 W
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 15 ms, R = 48 Ω, L = 0.24 H
>Duty factor
< 0.1 mA
Inductive load to EN 60947-5-1
>Without external suppressor circuit
>T0.95 = 15 ms, R = 48 Ω, L = 0.24 H
>Max. switching frequency f = 0.5 Hz (max. DF = 50 %)
2.5 (signal 0 at external load < 10 MΩ)
U = Ue - 1 V (signal 1 at Ie = 0.5 A) V
Inductive load to EN 60947-5-1
>With external suppressor circuit
>Utilization factor
Yes, electronic (Q1 - Q4), thermal (Q5 - Q8), (analysis via diagnostics input I16, I15)
Inductive load to EN 60947-5-1
>With external suppressor circuit
>Duty factor
0.7 ≦ Ie ≦ 2 per output A
Inductive load to EN 60947-5-1
>With external suppressor circuit
>Max. switching frequency, max. duty factor
16 A
Protection against polarity reversal 32 A
Potential isolation Yes
Bus termination (first and last station) 40000 Operations/h
Rated operational current for specified heat dissipation [In] Group 1: Q1 - Q4
Group 2: Q5 - Q8
Heat dissipation per pole, current-dependent [Pvid] 4
Equipment heat dissipation, current-dependent [Pvid] 2 (Caution! Outputs must be actuated simultaneously and for the same length of time.) A
Static heat dissipation, non-current-dependent [Pvs] LCD-display
Heat dissipation capacity [Pdiss] 0.25 g
Operating ambient temperature min. 100 % DF
Operating ambient temperature max. 1500 Operations
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0.25 g
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
100 % DF
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
1500 Operations
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0.25 g
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
100 % DF
10.2 Strength of materials and parts
>10.2.5 Lifting
1500 Operations
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
1 g
10.2 Strength of materials and parts
>10.2.7 Inscriptions
100 % DF
10.3 Degree of protection of ASSEMBLIES Depending on the suppressor circuit Operations
10.4 Clearances and creepage distances
10.5 Protection against electric shock yes (Caution: A short circuit will result if 0 V or earth is applied to the outputs in the event that the supply voltage is connected to the wrong poles.)
10.6 Incorporation of switching devices and components Yes
10.7 Internal electrical circuits and connections
10.8 Connections for external conductors EASY-NT-R plug (incl. bus terminating resistor 120 Ω)
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
0 A
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
0 W
10.10 Temperature rise 0 W
10.11 Short-circuit rating 3.4 W
10.12 Electromagnetic compatibility 0 W
10.13 Mechanical function -25 °C
Contains function building blocks +55 °C
Contains basic device
Contains module rack Meets the product standard´s requirements.
Contains power supply Meets the product standard´s requirements.
Contains analogue input module Meets the product standard´s requirements.
Contains analogue output module Meets the product standard´s requirements.
Contains digital input module Meets the product standard´s requirements.
Contains digital output module Does not apply, since the entire switchgear needs to be evaluated.
Contains function module Does not apply, since the entire switchgear needs to be evaluated.
Contains technology module Meets the product standard´s requirements.
Contains communication module Meets the product standard´s requirements.
Contains memory unit Meets the product standard´s requirements.
Contains simulation module Does not apply, since the entire switchgear needs to be evaluated.
Contains connection cable Does not apply, since the entire switchgear needs to be evaluated.
Contains control unit Is the panel builder´s responsibility.
Contains monitor Is the panel builder´s responsibility.
Contains programming software Is the panel builder´s responsibility.
Contains engineering software Is the panel builder´s responsibility.
Contains visualization Is the panel builder´s responsibility.
Contains libraries The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Contains documentation Is the panel builder´s responsibility.
Contains other components Is the panel builder´s responsibility.
Software preinstalled The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Product Standards
UL File No.
UL Category Control No. Yes
CSA File No. Yes
CSA Class No. No
North America Certification Yes
Specially designed for North America Yes
Current Limiting Circuit-Breaker Yes
Degree of Protection Yes