090900 MCS11-U

Pressure switch, 1W, 15bar
IEC EN 60947-5-1, IP65_x, pressure monitoring of liquid and gaseous media, e. g. compressed air, for actuation of the auxiliary circuits, make and break pressure: separately adjustable

Ürün Açıklaması

Pressure switch, 1W, 15bar
IEC EN 60947-5-1, IP65_x, pressure monitoring of liquid and gaseous media, e. g. compressed air, for actuation of the auxiliary circuits, make and break pressure: separately adjustable
Product range Pressure switches with auxiliary contacts
Degree of Protection IP65
Notes Variable switching differential
Standards

Features:

  • Pressure pipe flange R ¼”
  • If required: pressure pipe flange R ½”
  • IP65 in conjunction with V-M20 cable gland
  • 1 Insulated protective conductor terminal
  • 2 cable entry knockouts for M20
  • Neoprene membrane, resistant to aging, air, engine oil, and water min. -25 °C, max. +80 °C

Cut-in and cut-out pressures are factory-preset as specified with type suffix: →#203948

R ¼” corresponds to G ¼

R ½” corresponds to G ½ according to ISO 228-1

Auxiliary contact to IEC/EN 60947-1

Test pressure IEC/EN 60947-5-1
Rupturing pressure 32 bar
Climatic proofing 90 bar
Ambient temperature Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Degree of Protection 25 - 70
Mounting position IP65
Mechanical shock resistance to IEC 60068-2-27 [Half-sinusoidal shock 20 ms] As required
Vibration resistance acc. to IEC/EN 60068-2-6 [Amplitude 1 mm] > 10 g
Terminal capacities
>Solid
36 Hz
Terminal capacities
>Flexible with ferrules to DIN 46228
1 x (0.75 - 2.5) mm2
Terminations 1 x (0.5 - 1.5) mm2
Terminal screw Tunnel terminal
Tightening torque of terminal screw M3
Rated impulse withstand voltage [Uimp] 0.5 Nm
Rated insulation voltage [Ui ] 4000 V AC
Overvoltage category/pollution degree 400 V
Max. short-circuit protective device
>Fuse [gG/gL]
III/3
DC-13
>Rated operational current
>24 V
10 A
DC-13
>Rated operational current
>110 V
2 A
Rated frequency [f] 0.25 A
Operating ambient temperature min. 50 Hz
Operating ambient temperature max. 25 °C
Suitable as guard +70 °C
Suitable as 2-point controller Yes
Suitable as limiter Yes
Max. operation pressure No
Engaging pressure 15000 hPa
Initial setting 0 - 10.4 bar
Switch off pressure 0 - 0 hPa
End setting 0 - 11 bar
Pressure-switching differential 0 - 0 hPa
Max. test pressure 0 bar
Bursting pressure 32 bar
Medium temperature 90 bar
Connection 25 - 80 °C
Thread size Inner thread gas cylindrical (BSPP)
Rated voltage Ue at AC 50 Hz 1/4 inch
Rated voltage Ue at AC 60 Hz 0 - 230 V
Rated voltage Ue at DC 0 - 230 V
Initial value measuring range pressure 0 - 110 V
End value measuring range pressure 0 Pa
Rated operation power at AC-3, 400 V 0 Pa
Switching capacity at AC-3, 240 V 0 kW
Rated operation current Ie at AC-1, 400 V 0 kA
Rated operation current Ie at AC-3, 400 V 0 A
Number of auxiliary contacts as normally open contact 0 A
Number of auxiliary contacts as normally closed contact 0
Number of auxiliary contacts as change-over contact 0
Type of electric connection 1
Number of normally closed contacts as main contact Screw connection
Number of main contacts as normally open contact 0
Adjustable current range 0
With hand operation 0 - 0 A
With manual on/off switch No
Electronic version No
With display No
Explosion-proof No
Degree of protection (IP) No
Degree of protection (NEMA) IP65
Height Other
Width 100 mm
Diameter 60 mm
Depth 0 mm