088917 PKZM0-16-T

Transformer-protective circuit-breaker, 3p, Ir=10-16A, screw connection
Transformer circuit-breaker according to IEC/EN60947, 3 pole size PKZM0, with adjustable overload and non-delayed short-circuit release, phase failure sensitive, screw and snap fitting, with screw terminal, cap installation dimension 45mm, rated operating voltage Ue 690V, degree of protection IP20, finger proof according to VDE 0106 T. 100, accessories: auxiliary contact, voltage release

Ürün Açıklaması

Transformer-protective circuit-breaker, 3p, Ir=10-16A, screw connection
Transformer circuit-breaker according to IEC/EN60947, 3 pole size PKZM0, with adjustable overload and non-delayed short-circuit release, phase failure sensitive, screw and snap fitting, with screw terminal, cap installation dimension 45mm, rated operating voltage Ue 690V, degree of protection IP20, finger proof according to VDE 0106 T. 100, accessories: auxiliary contact, voltage release
Product range PKZM0...T transformer-protective circuit-breakers up to 25 A
Basic function Transformer protection
Notes 0000SPC-571
Connection technique Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Contact sequence Screw terminals
Rated uninterrupted current [Iu] 121S003
Overload releases [Ir ] 16 A
short-circuit release [Irm ]
>max. [Irm ]
Phase-failure sensitivity 10 - 16 A
Notes 280 A
Standards IEC/EN 60947-4-1, VDE 0660 Part 102
Climatic proofing For the protection of transformers with a high inrush current.
Can be snapped on to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height.
Ambient temperature
>Storage
Ambient temperature
>Open
IEC/EN 60947, VDE 0660
Ambient temperature
>Enclosed
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mounting position - 40 - 80 °C
Direction of incoming supply -25 - +55 °C
Degree of protection
>Device
- 25 - 40 °C
Degree of protection
>Terminations
1210DRW-68
Protection against direct contact when actuated from front (EN 50274) as required
Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27 IP20
Altitude IP00
Terminal capacity main cable
>Screw terminals
>Solid
Finger and back-of-hand proof
Terminal capacity main cable
>Screw terminals
>Flexible with ferrule to DIN 46228
25 g
Terminal capacity main cable
>Screw terminals
>Solid or stranded
Max. 2000 m
Terminal capacity main cable
>Screw terminals
>Stripping length
1 x (1 - 6)
2 x (1 - 6) mm2
Specified tightening torque for terminal screws
>Main cable
1 x (1 - 6)
2 x (1 - 6) mm2
Specified tightening torque for terminal screws
>Control circuit cables
18 - 10 AWG
Rated impulse withstand voltage [Uimp] 10 mm
Overvoltage category/pollution degree 1.7 Nm
Rated operational voltage [Ue ] 1 Nm
Rated uninterrupted current = rated operational current [Iu = Ie ]
Rated frequency [f] 6000 V AC
Current heat loss (3 pole at operating temperature) III/3
Lifespan, mechanical [Operations] 690 V AC
Lifespan, electrical (AC-3 at 400 V)
>Lifespan, electrical [Operations]
16 A
Max. operating frequency 40 - 60 Hz
Short-circuit rating
>DC
>Short-circuit rating
6 W
Motor switching capacity
>AC-3 (up to 690V)
0.1 x 106
Motor switching capacity
>DC-5 (up to 250V)
0.1 x 106
Temperature compensation
>to IEC/EN 60947, VDE 0660
40 Ops/h
Temperature compensation
>Operating range
60 kA
Temperature compensation residual error for T > 40 °C 16 A
Setting range of overload releases 16 (3 contacts in series) A
short-circuit release
Short-circuit release tolerance - 5…40 °C
Phase-failure sensitivity - 25…55 °C
Rated operational current for specified heat dissipation [In] ≦ 0.25 %/K
Heat dissipation per pole, current-dependent [Pvid] 0.6 - 1 x Iu
Equipment heat dissipation, current-dependent [Pvid] Basic device, fixed: 20 x Iu
Static heat dissipation, non-current-dependent [Pvs] ± 20%
Heat dissipation capacity [Pdiss] IEC/EN 60947-4-1, VDE 0660 Part 102
Operating ambient temperature min.
Operating ambient temperature max. 16 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
2 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
6 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
-25 °C
10.2 Strength of materials and parts
>10.2.5 Lifting
+55 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Rated permanent current Iu Is the panel builder´s responsibility.
Rated voltage Is the panel builder´s responsibility.
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz Is the panel builder´s responsibility.
Overload release current setting The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Adjustment range short-term delayed short-circuit release Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Adjustment range undelayed short-circuit release Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Integrated earth fault protection The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Type of electrical connection of main circuit
Device construction
Suitable for DIN rail (top hat rail) mounting 16 A
DIN rail (top hat rail) mounting optional 690 - 690 V
Number of auxiliary contacts as normally closed contact 50 kA
Number of auxiliary contacts as normally open contact 16 - 16 A
Number of auxiliary contacts as change-over contact 0 - 0 A
With switched-off indicator 358 - 358 A
With under voltage release No
Number of poles Screw connection
Position of connection for main current circuit Other
Type of control element Yes
Complete device with protection unit Yes
Motor drive integrated 0
Motor drive optional 0
Degree of protection (IP) 0
Specially designed for North America Yes
Accessories No
Characteristic curve 3
Characteristic curve Other
Characteristic curve Turn button