SKU: Eaton-032314
Connection, asi, of RMQ22, for surface mounting enclosure
Accessories for the control circuit devices program
Product range | Accessories |
Accessories | AS-Interface |
Basic function accessories | AS-Interface connection |
Fixing | Front fixing for RMQ-Titan |
Connection to SmartWire-DT | External connections: 4 inputs/4 outputs For contact and lamp socket elements. RMQ-Titan surface mounting enclosures: M22-I3, M22-I4, M22-I6 |
Standards | no |
Radio interference suppression | EN 50081-1 EN 50082-1 |
Limit value class | EN 55011, EN 55022 |
Degree of Protection | A |
Climatic proofing | IP20 |
Ambient temperature >Open |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mechanical shock resistance | -25 - +55 °C |
Vibration to IEC 60068-2-27 (amplitude 1 mm) | > 30 Shock duration 11 ms g |
Dimensions | 1055 Hz |
Weight | 92 x 46 x 30 mm |
Fixing | 0.1 kg |
Mounting position | Front fixing for RMQ-Titan |
Rated voltage to AS-Interface Specification | As required |
Power supply | 26.5 - 31.6 V DC |
Addressing | Completely from the AS-Interface cable |
AS-Interface | Via connection to AS-Interface cable |
Rated operational current at full load | Protected against polarity reversal |
Rated operational current when idle (no I, O set) | 120 mA |
Status LEDs | 30 mA |
Voltage range | AS-Interface voltage: green LED |
Rated current per input | 24 - 30 V DC |
High signal level | 3.5 mA |
Length of connecting cables | ≧ 15 V |
Outputs, protected against short-circuit | 200 cm |
Voltage range | 4 Number |
Max. current carrying capacity >Σ 3 external outputs |
24 V DC (+10/-15%) V DC |
Length of connecting cables | 60 |
Profile | 200 cm |
Specification | S-7.0 |
Addresses | 2.0 |
Rated operational current for specified heat dissipation [In] | 31 Number |
Heat dissipation per pole, current-dependent [Pvid] | 0 A |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 1.5 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | -25 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
+55 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Please enquire |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Type of electrical accessory | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Type of mechanical accessory | Other |