002213 CI43X-125-NA

Insulated enclosure, smooth sides, HxWxD=250x375x150mm, NA type
Individual basic enclosure, UL approved, material characteristic polycarbonate, impact-resistant, degree of protection IP65, optional lockable with DVZ...-CI, patented cover fasteners with integrated overpressure compensation, smooth sides, without knockouts, fixing straps for wall fixing, sealable cover fasteners, RAL 7035, grey (base), transparent smoky, (cover), mounting depth with mounting plate=125mm, cover type: transparent smoky, base type: smooth

Ürün Açıklaması

Insulated enclosure, smooth sides, HxWxD=250x375x150mm, NA type
Individual basic enclosure, UL approved, material characteristic polycarbonate, impact-resistant, degree of protection IP65, optional lockable with DVZ...-CI, patented cover fasteners with integrated overpressure compensation, smooth sides, without knockouts, fixing straps for wall fixing, sealable cover fasteners, RAL 7035, grey (base), transparent smoky, (cover), mounting depth with mounting plate=125mm, cover type: transparent smoky, base type: smooth
Product range xEnergy Safety Ci
Basic function Basic enclosures
Product function Individual enclosure for North America
Individual enclosures with covers
Single unit/Complete unit Stand-alone device
Standards UL508A
Degree of Protection IP65
Description Smooth side plates, without knockouts
Sealable cover fasteners
Include fixing straps for wall mounting
Colour RAL 7035, light gray (base)
Transparent, smoky gray (cover)
Width
Height 375 mm
Depth 250 mm
Mounting depth: 150 mm
Type cover 125 mm
Model base Transparent
Standards RAL 7035, smooth sides
Climatic proofing
Ambient temperature UL508A
Degree of Protection Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Operating and ambient conditions to VDE 0660 Part 500
>Surface finish
-40 - +80 °C
Surface treatment IP65
Surface finish RAL 7035 (base)
Electrical
>Track resistance
Electrical
>Surface resistance to IEC 60093
Resistant to corrosion
Electrical
>Dielectric strength to IEC 60243-1
RAL 7035 (base)
Mechanical
>Impact resistance
Atmospheric
>Saline spray
KB160, KC175 (base, to IEC 60112)
KB100, KC200 (cover, to IEC 60112)
Atmospheric
>UV resistance
1 Ω x 1013
Atmospheric
>Water consumption to DIN EN ISO 62
30 kV/mm
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV]
please require
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV]
IEC 60068-2-11
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV]
Beneath protective shield
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV]
0.29 %
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV]
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV]
20 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
19 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
18 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
41 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
39 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
37 W
10.2 Strength of materials and parts
>10.2.5 Lifting
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Lower part: 960 °C / cover: 850 °C; meets the product standard´s requirements.
10.5 Protection against electric shock Not relevant to indoor installations.
10.6 Incorporation of switching devices and components 10 kg per enclosure with support frame and lifting aid met; assembled and secured as per the latest applicable instruction leaflet.
10.7 Internal electrical circuits and connections IK10
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
IP65
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Protection class 2, therefore not applicable.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Ui = 1000 V AC
Mounting method 8 kV
Type of cover Meets the product standard´s requirements.
Cover model The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Type of door Is the panel builder´s responsibility.
Transparent cover/door Is the panel builder´s responsibility.
With lock Meets the product standard´s requirements.
Nominal current (In)
Height
Width Surface mounted (plaster)
Depth Optional
Built-in depth Closed
Internal depth None
Plate thickness cabinet Yes
Plate thickness door/cover No
Colour 1600 A
RAL-number 250 mm
Number of modules 375 mm
Number of rows 150 mm
Width in number of modular spacings 125 mm
Number of openings for flange plates 125 mm
Extension possible 9 mm
Number of conduit inlets 6 mm
Material housing Grey
Surface protection 7035
With mounting plate 1
Suitable for outdoor use 0
Suitable for lightning protection 15
Degree of protection (IP) 0
Degree of protection (NEMA) No
Protection class 0
Impact strength Plastic
Circuit integrity Other
Product Standards No
UL File No. Yes
UL Category Control No. Yes
North America Certification IP65
Specially designed for North America 4X
Suitable for II
Degree of Protection IK10