000641 DILEM-10(TVC200)

Contactor, 200 V 50Hz, 200-220 V 60Hz, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, AC operation
Contactor, Application: Mini Contactors for Motors and Resistive Loads, DILEM contactors, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: With auxiliary contact, Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 9 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 22 A, enclosed: Ith= 16 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 50 A, enclosed: Ith= 40 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 2.2 kW, 380 V 400 V: P= 4 kW, 660 V 690 V: P= 4 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 1.5 kW, 380 V 400 V: P= 3 kW, 660 V 690 V: P= 3 kW, For use with: …DILEM, …DILE, Contacts N/O = Normally open: 1 N/O, Voltage AC/DC: AC operation

Ürün Açıklaması

Contactor, 200 V 50Hz, 200-220 V 60Hz, 3 pole, 380 V 400 V, 4 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, AC operation
Contactor, Application: Mini Contactors for Motors and Resistive Loads, DILEM contactors, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: With auxiliary contact, Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 9 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 22 A, enclosed: Ith= 16 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 50 A, enclosed: Ith= 40 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 2.2 kW, 380 V 400 V: P= 4 kW, 660 V 690 V: P= 4 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 1.5 kW, 380 V 400 V: P= 3 kW, 660 V 690 V: P= 3 kW, For use with: …DILEM, …DILE, Contacts N/O = Normally open: 1 N/O, Voltage AC/DC: AC operation
Product range Contactors
Application Mini Contactors for Motors and Resistive Loads
Subrange DILEM contactors
Utilization category AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Notes 0000SPC-571
Connection technique Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Description Screw terminals
Number of poles With auxiliary contact
AC-3
>380 V 400 V [Ie]
3 pole
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
AC-3
>220 V 230 V [P]
9 A
AC-3
>380 V 400 V [P]
22 A
AC-3
>660 V 690 V [P]
AC-4
>220 V 230 V [P]
2.2 kW
AC-4
>380 V 400 V [P]
4 kW
AC-4
>660 V 690 V [P]
4 kW
N/O = Normally open 1.5 kW
Contact sequence 3 kW
For use with 3 kW
Actuating voltage
Voltage AC/DC 1 N/O
Standards 210S026
Lifespan, mechanical; Coil 50/60 Hz [Operations] …DILEM
…DILE
Lifespan, mechanical [Operations] 200 V 50Hz, 200-220 V 60Hz
Maximum operating frequency
>Mechanical
AC operation
Maximum operating frequency
>electrical (Contactors without overload relay) [Operations/h]
Climatic proofing IEC/EN 60947, VDE 0660, CSA, UL
Ambient temperature
>Open
7 x 106
Ambient temperature
>Enclosed
10 x 106
Ambient temperature
>Storage
>Min. ambient temperature, storage
9000 Ops./h
Ambient temperature
>Storage
>Ambient temperature, storage max.
See characteristic curves
Mounting position Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mounting position -25 - +50 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit without auxiliary contact module
>Main contacts, make contacts
- 25 - 40 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit without auxiliary contact module
>Main contacts Make/break contacts
>Make
- 40 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit with auxiliary contact module
>Main contacts make contact
>Make
+ 80 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit with auxiliary contact module
>Auxiliary contacts Make/break contacts
As required, except vertical with terminals A1/A2 at the bottom
Degree of Protection 230K003
Protection against direct contact when actuated from front (EN 50274) 10 g
Altitude 8 g
Weight 10 g
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Solid
20/20 g
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Flexible with ferrule
IP20
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Solid or stranded
Finger and back-of-hand proof
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Stripping length
Max. 2000 m
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Terminal screw
0.17 kg
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Pozidriv screwdriver
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Standard screwdriver
1 x (0.75 - 1.5)
2 x (0.75 - 1.5) mm2
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Max. tightening torque
18 - 14 AWG
Rated impulse withstand voltage [Uimp] 8 mm
Overvoltage category/pollution degree M3.5
Rated insulation voltage [Ui] 2 Size
Rated operational voltage [Ue] 0.8 x 5.5
1 x 6 mm
Safe isolation to EN 61140
>between coil and contacts
1.2 Nm
Safe isolation to EN 61140
>between the contacts
Making capacity (cos ϕ to IEC/EN 60947) 6000 V AC
Breaking capacity
>220 V 230 V
III/3
Breaking capacity
>380 V 400 V
690 V AC
Breaking capacity
>500 V
690 V AC
Breaking capacity
>660 V 690 V
300 V AC
Short-circuit protection maximum fuse
>Type ”2”, 500 V [gL/gG]
300 V AC
Short-circuit protection maximum fuse
>Type ”1”, 500 V [gL/gG]
110 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
90 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 50 °C [Ith =Ie]
90 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>enclosed [Ith ]
64 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Notes
42 A
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>Notes
10 A
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>open [Ith ]
20 A
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>enclosed [Ith ]
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>Notes
22 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie]
20 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie]
16 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
At maximum permissible ambient air temperature.
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie]
At maximum permissible ambient air temperature.
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>440V [Ie]
50 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie]
40 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie]
At maximum permissible ambient temperature (open.)
AC-3
>Motor rating [P]
>220 V 230 V [P]
9 A
AC-3
>Motor rating [P]
>240V [P]
9 A
AC-3
>Motor rating [P]
>380 V 400 V [P]
9 A
AC-3
>Motor rating [P]
>415 V [P]
9 A
AC-3
>Motor rating [P]
>440 V [P]
9 A
AC-3
>Motor rating [P]
>500 V [P]
6.4 A
AC-3
>Motor rating [P]
>660 V 690 V [P]
4.8 A
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>Notes
2.2 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie ]
2.5 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie ]
4 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie ]
4.3 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie ]
4.6 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>440 V [Ie ]
4 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie ]
4 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie ]
At maximum permissible ambient air temperature.
AC-4
>Motor rating [P]
>220 V 230 V [P]
6.6 A
AC-4
>Motor rating [P]
>240 V [P]
6.6 A
AC-4
>Motor rating [P]
>380 V 400 V [P]
6.6 A
AC-4
>Motor rating [P]
>415 V [P]
6.6 A
AC-4
>Motor rating [P]
>440 V [P]
6.6 A
AC-4
>Motor rating [P]
>500 V [P]
5 A
AC-4
>Motor rating [P]
>660 V 690 V [P]
3.4 A
Rated operational current open
>DC-1
>12 V [Ie ]
1.5 kW
Rated operational current open
>DC-1
>24 V [Ie ]
1.8 kW
Rated operational current open
>DC-1
>60 V [Ie ]
3 kW
Rated operational current open
>DC-1
>110 V [Ie ]
3.1 kW
Rated operational current open
>DC-1
>220 V [Ie ]
3.3 kW
Current heat losses (3- or 4-pole)
>at Ith, 50 °C
3 kW
Current heat losses (3- or 4-pole)
>at Ie to AC-3/400 V
3 kW
Voltage tolerance
>AC operated
>Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Pick-up]
Voltage tolerance
>AC operated
>Dual-frequency coil 50/60 Hz [Pick-up]
>Voltage tolerance Dual-frequency coil 50/60 Hz, max. pick-up voltage
20 A
Power consumption
>AC operation
>Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Pick-up]
20 A
Power consumption
>AC operation
>Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Pick-up]
20 A
Power consumption
>AC operation
>Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Sealing]
20 A
Power consumption
>AC operation
>Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Sealing]
20 A
Duty factor 5.9 W
Switching times at 100 % Uc
>Make contact
>Closing delay
>Closing delay min.
1.2 W
Switching times at 100 % Uc
>Make contact
>Closing delay
>Closing delay max.
Switching times at 100 % Uc
>Make contact
>Opening delay
>Opening delay min.
0.85 - 1.1 x Uc
Switching times at 100 % Uc
>Make contact
>Opening delay
>Opening delay max.
1.1 x Uc
Switching times at 100 % Uc
>Make contact
>Closing delay with top mounting auxiliary contact
25 VA
Switching times at 100 % Uc
>Reversing contactors
>Changeover time at 110 % Uc
>Changeover time min.
22 W
Switching times at 100 % Uc
>Reversing contactors
>Changeover time at 110 % Uc
>Changeover time max.
4.6 VA
Switching times at 100 % Uc
>Reversing contactors
>Arcing time at 690 V AC
1.8 W
Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module 100 % DF
Rated impulse withstand voltage [Uimp ] 14 ms
Overvoltage category/pollution degree 21 ms
Rated insulation voltage [Ui ] 8 ms
Rated operational voltage [Ue ] 18 ms
Safe isolation to EN 61140
>between coil and auxiliary contacts
45 ms
Safe isolation to EN 61140
>between the auxiliary contacts
16 ms
Rated operational current
>AC-15
>220 V 240 V [Ie]
21 ms
Rated operational current
>AC-15
>380 V 415 V [Ie]
12 ms
Rated operational current
>AC-15
>500 V [Ie]
Rated operational current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [24 V]
Yes
Rated operational current
>DC L/R ≦ 15 ms
>Contacts in series:
>2 [60 V]
6000 V AC
Rated operational current
>DC L/R ≦ 15 ms
>Contacts in series:
>3 [100 V]
III/3
Rated operational current
>DC L/R ≦ 15 ms
>Contacts in series:
>3 [220 V]
690 V AC
Conv. thermal current [Ith] 600 V AC
Control circuit reliability [Failure rate] 300 V AC
Component lifespan at Ue = 240 V
>AC-15 [Operations]
300 V AC
Component lifespan at Ue = 240 V
>DC current
>L/R = 50 ms: 2 contacts in series at Ie = 0.5 A [Operations]
6 A
Component lifespan at Ue = 240 V
>DC current
>Notes
3 A
Short-circuit rating without welding
>Maximum overcurrent protective device
>Short-circuit protection only
1.5 A
Short-circuit rating without welding
>Short-circuit protection maximum fuse
>500 V
2.5 A
Short-circuit rating without welding
>Short-circuit protection maximum fuse
>500 V
2.5 A
Current heat loss at a load of Ith per contact 1.5 A
Switching capacity
>Maximum motor rating
>Three-phase
>200 V
208 V
0.5 A
Switching capacity
>Maximum motor rating
>Three-phase
>230 V
240 V
10 A
Switching capacity
>Maximum motor rating
>Three-phase
>460 V
480 V
<10-8, < one failure at 100 million operations
(at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) λ
Switching capacity
>Maximum motor rating
>Three-phase
>575 V
600 V
0.2 x 106
Switching capacity
>Maximum motor rating
>Single-phase
>115 V
120 V
0.15 x 106
Switching capacity
>Maximum motor rating
>Single-phase
>230 V
240 V
Switch-on and switch-off conditions based on DC-13, time constant as specified
Switching capacity
>General use
PKZM0-4
Auxiliary contacts
>Pilot Duty
>AC operated
6 A gG/gL
Auxiliary contacts
>Pilot Duty
>DC operated
10 A fast
Auxiliary contacts
>General Use
>AC
1.1 W
Auxiliary contacts
>General Use
>AC
Auxiliary contacts
>General Use
>DC
2 HP
Auxiliary contacts
>General Use
>DC
3 HP
Short Circuit Current Rating
>Basic Rating
>SCCR
5 HP
Short Circuit Current Rating
>Basic Rating
>max. Fuse
5 HP
Rated operational current for specified heat dissipation [In] 0.5 HP
Heat dissipation per pole, current-dependent [Pvid] 1.5 HP
Equipment heat dissipation, current-dependent [Pvid] 15 A
Static heat dissipation, non-current-dependent [Pvs] A600
Heat dissipation capacity [Pdiss] P300
Operating ambient temperature min. 600 V
Operating ambient temperature max. 10 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
250 V
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0.5 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
5 kA
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
45 A
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
10.2 Strength of materials and parts
>10.2.5 Lifting
9 A
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
0.4 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
1.2 W
10.3 Degree of protection of ASSEMBLIES 1.8 W
10.4 Clearances and creepage distances 0 W
10.5 Protection against electric shock -25 °C
10.6 Incorporation of switching devices and components +50 °C
10.7 Internal electrical circuits and connections
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Meets the product standard´s requirements.
Rated control supply voltage Us at AC 50HZ Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at AC 60HZ Meets the product standard´s requirements.
Rated control supply voltage Us at DC Does not apply, since the entire switchgear needs to be evaluated.
Voltage type for actuating Does not apply, since the entire switchgear needs to be evaluated.
Rated operation current Ie at AC-1, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-4, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-4, 400 V Is the panel builder´s responsibility.
Rated operation power NEMA The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Modular version Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally open contact Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally closed contact The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Type of electrical connection of main circuit
Number of normally closed contacts as main contact
Number of main contacts as normally open contact 200 - 200 V
Product Standards 200 - 220 V
UL File No. 0 - 0 V
UL Category Control No. AC
CSA File No. 22 A
CSA Class No. 9 A
North America Certification 4 kW
Specially designed for North America 6.6 A
Accessories 3 kW
Characteristic curve 3.7 kW
Characteristic curve No
Characteristic curve 1
Characteristic curve 0