LS-11S/L-CC

Roller lever, Cold Climate -40 °C

Ürün Açıklaması

Roller lever, Cold Climate -40 °C
Basic function Position switches
Safety position switches
Part group reference LS(M)-…
Product range Roller lever
Degree of Protection IP65
Features Complete device
Ambient temperature -40 - +70 °C
N/O = Normally open 1 N/O
N/C = Normally closed 1 NC
Enclosure covers Yellow
Enclosure covers 116C064
Housing Insulated material
Connection type Cage Clamp
Standards IEC/EN 60947
Climatic proofing Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30
Ambient temperature -40 - +70 °C
Mounting position As required
Degree of Protection IP65
Terminal capacities
>Solid
1 x (0.5 - 2.5) mm2
Terminal capacities
>Flexible with ferrule
1 x (0.5 - 1.5) mm2
Repetition accuracy 0.15 mm
Rated impulse withstand voltage [Uimp] 4000 V AC
Rated insulation voltage [Ui ] 400 V
Overvoltage category/pollution degree III/3
Rated operational current [Ie ]
>AC-15
>24 V [Ie ]
6 A
Rated operational current [Ie ]
>AC-15
>220 V 230 V 240 V [Ie]
6 A
Rated operational current [Ie ]
>AC-15
>380 V 400 V 415 V [Ie]
4 A
Rated operational current [Ie ]
>DC-13
>24 V [Ie ]
3 A
Rated operational current [Ie ]
>DC-13
>110 V [Ie ]
0.6 A
Rated operational current [Ie ]
>DC-13
>220 V [Ie ]
0.3 A
Control circuit reliability
>at 24 V DC/5 mA [HF ]
< 10 -7, < 1 fault in 107 operations Fault probability
Control circuit reliability
>at 5 V DC/1 mA [HF ]
< 5 x 10-6, < 1 failure at 5 x 106 operations Fault probability
Supply frequency max. 400 Hz
Short-circuit rating to IEC/EN 60947-5-1
>max. fuse
6 A gG/gL
Mechanical shock resistance (half-sinusoidal shock, 20 ms)
>Standard-action contact
25 g
Operating frequency [Operations/h] ≦ 6000
Mechanical
>Actuating torque of rotary drives
0.2 Nm
Mechanical
>Max. operating speed with DIN cam
1 m/s
Mechanical
>Notes
for angle of actuation α = 30°/45°