290385 NZMH4-ME1400-S1

Circuit-breaker, 3p, 1400A 1000V
Series NZM..-ME circuit-breakers cover all application cases with just four compact sizes and are suitable for the IEC market. Modular function groups always make mounting flexible. With electronic release for motor protection with phase failure sensitivity. Notes: r.m.s. value measurement and thermal memory, adjustable time delay setting to overcome current peaks tr:2-20 at 6xIr as well as infinity (without overload release), NZM...S1 terminal type: NZM...XKSA cover required, NZM4...S1 terminal type: Insulated busbar connection (NZM4-XKS screw connection)

Ürün Açıklaması

Circuit-breaker, 3p, 1400A 1000V
Series NZM..-ME circuit-breakers cover all application cases with just four compact sizes and are suitable for the IEC market. Modular function groups always make mounting flexible. With electronic release for motor protection with phase failure sensitivity. Notes: r.m.s. value measurement and thermal memory, adjustable time delay setting to overcome current peaks tr:2-20 at 6xIr as well as infinity (without overload release), NZM...S1 terminal type: NZM...XKSA cover required, NZM4...S1 terminal type: Insulated busbar connection (NZM4-XKS screw connection)
Product range Circuit-breaker
Protective function Motor protection
Standard/Approval 0000SPC-571
Installation type IEC
Release system Fixed
Construction size Electronic release
Description NZM4
Number of poles Phase-failure sensitivity
IEC/EN 60947-4-1, IEC/EN 60947-2
R.m.s. value measurement and “thermal memory”
adjustable time delay setting to overcome current peaks tr: 2 – 20 s at 6 x Ir also infinity (without overload releases)
NZM...S1 terminal type: NZM...XKSA cover required
NZM4...S1 terminal type: Insulated busbar connection (NZM4-XKS screw connection)
Standard equipment 3 pole
Rated current = rated uninterrupted current [In = Iu] Screw connection
1000 V 50/60 Hz [Icu] 1400 A
Overload trip [Ir ]
700 - 1400 A
Short-circuit releases [Irm ]
>Non-delayed [Ii = Ir x …]
20 kA
Rated surge voltage invariability [Uimp ]
>Main contacts
700 - 1400 A
Rated surge voltage invariability [Uimp ]
>Auxiliary contacts
2 - 14
Rated operational voltage [Ue] 8000 V
Rated current = rated uninterrupted current [In = Iu] 6000 V
Overvoltage category/pollution degree 1000 V AC
Rated insulation voltage [Ui ] 1400 A
Utilization category III/3
Ambient temperature
>Ambient temperature, storage
1000 V
Ambient temperature
>Operation
B
240 V 50/60 Hz [Icm ] - 40 - + 70 °C
400/415 V 50/60 Hz [Icm ] -25 - +70 °C
440 V 50/60 Hz [Icm ] 275 kA
525 V 50/60 Hz [Icm ] 187 kA
690 V 50/60 H [Ic] 187 kA
1000 V 50/60 Hz [Icm] 143 kA
Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>240 V 50/60 Hz [Icu ]
100 kA
Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>400/415 V 50 Hz [Icu ]
40 kA
Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>440 V 50/60 Hz [Icu ]
125 kA
Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>525 V 50/60 Hz [Icu ]
85 kA
Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>690 V 50/60 Hz [Icu ]
85 kA
Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>1000 V 50/60 Hz [Icu]
65 kA
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>230 V 50/60 Hz [Ics ]
50 kA
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>400/415 V 50/60 Hz [Ics ]
20 kA
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>440 V 50/60 Hz [Ics ]
63 kA
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>525 V 50/60 Hz [Ics ]
50 kA
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>690 V 50/60 Hz [Ics]
50 kA
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>1000 V AC [Ics]
50 kA
t = 0.3 s [Icw ] 37 kA
t = 1 s [Icw ] 15 kA
Lifespan, mechanical [Operations] 19.2 kA
Max. operating frequency 19.2 kA
1000 V 50/60 Hz [Operations] 10000
Standard equipment 60 Ops/h
Round copper conductor
>Tunnel terminal
>Stranded
>4-hole
Lifespan, mechanical: of which max. 50 % trip by shunt/undervoltage release
Round copper conductor
>Bolt terminal and rear-side connection
>Module plate
>Single hole [min.]
500
Round copper conductor
>Bolt terminal and rear-side connection
>Module plate
>Single hole [max.]
Screw connection
Round copper conductor
>Bolt terminal and rear-side connection
>Module plate
>Double hole [min.]
4 x (50 - 240)
mm2
Round copper conductor
>Bolt terminal and rear-side connection
>Module plate
>Double hole [max.]
1 x (185 - 240) mm2
Round copper conductor
>Bolt terminal and rear-side connection
>Connection width extension
>Connection width extension
2 x (70 - 185) mm2
Al conductors, Cu cable
>Tunnel terminal
>Stranded
>4-hole
4 x 50 mm2
Cu strip (number of segments x width x segment thickness)
>Flat conductor terminal [min.]
4 x (35 - 185) mm2
Cu strip (number of segments x width x segment thickness)
>Flat conductor terminal [max.]
2 x 240
6 x (70 - 240) mm2
Cu strip (number of segments x width x segment thickness)
>Module plate
>Single hole
4 x (50 - 240)
mm2
Cu strip (number of segments x width x segment thickness)
>Bolt terminal and rear-side connection
>Flat copper strip, with holes [min.]
6 x 16 x 0.8 mm
Cu strip (number of segments x width x segment thickness)
>Bolt terminal and rear-side connection
>Flat copper strip, with holes [max.]
(2 x) 10 x 32 x 1.0 mm
Cu strip (number of segments x width x segment thickness)
>Bolt terminal and rear-side connection
>Connection width extension
(2 x) 10 x 50 x 1.0 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Screw connection
(2 x) 10 x 50 x 1.0 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [min.]
(2 x) 10 x 50 x 1.0 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [max.]
(2 x) 10 x 80 x 1.0 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Module plate
>Single hole [min.]
M10
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Module plate
>Single hole [max.]
25 x 5 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Module plate
>Double hole
2 x (50 x 10)
2 x (80 x 10) mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Connection width extension
>Connection width extension [min.]
25 x 5 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Connection width extension
>Connection width extension [max.]
2 x (50 x 10)
mm
Control cables 2 x (50 x 10) mm
Rated operational current for specified heat dissipation [In] 60 x 10 mm
Equipment heat dissipation, current-dependent [Pvid] 2 x (80 x 10) mm
Operating ambient temperature min. 1 x (0.75 - 2.5)
2 x (0.75 - 1.5) mm2
Operating ambient temperature max. 1400 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
217.56 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
-25 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
+70 °C
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Overload release current setting Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Adjustment range undelayed short-circuit release Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
With thermal protection The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Phase failure sensitive 700 - 1400 A
Switch off technique 1400 - 19600 A
Rated operating voltage Yes
Rated permanent current Iu Yes
Rated operation power at AC-3, 230 V Electronic
Rated operation power at AC-3, 400 V 1000 - 1000 V
Type of electrical connection of main circuit 1400 A
Type of control element 450 kW
Device construction 800 kW
With integrated auxiliary switch Screw connection
With integrated under voltage release Rocker lever
Number of poles Built-in device fixed built-in technique
Rated short-circuit breaking capacity lcu at 400 V, AC No
Degree of protection (IP) No
Height 3
Width 150 kA
Depth IP20
Characteristic curve 207 mm