SKU: Eaton-285316

285316 XT-FIL-1

Interference filter for the external supply of the 24VDC XC100/200
For suppressing interference of the external 24VDC supply of the XC100/200. Maximum current consumption 2.2A.

Ürün Açıklaması

Interference filter for the external supply of the 24VDC XC100/200
For suppressing interference of the external 24VDC supply of the XC100/200. Maximum current consumption 2.2A.
Accessories Filtering:
Description Interference suppression of the external 24 V DC supply of the XC100/200
Max. current consumption 2.2 A
Information relevant for export to North America

Product Standards IEC: see Technical Data; UL508; CSA-C22.2 No. 0-M; CSA-C22.2 No. 142-M; CE marking

UL File No. E135462

UL Category Control No. NRAQ

CSA File No. 012528

CSA Class No. 2252-01

North America Certification UL listed, CSA certified

Degree of Protection IEC: IP20, UL/CSA Type: -

Standards
Ambient temperature IEC/EN 61131-2
EN 50178
Storage [ϑ] 0 - +55 °C
Mounting position -25 - +70 °C
Vibration resistance Vertical or horizontal
Mechanical shock resistance 10 - 57 Hz ± 0.075 mm
57 - 150 Hz ± 1.0 g
Impact resistance 15
Shock duration 11 ms g
Overvoltage category/pollution degree 500 g/⌀ 50 mm ±25 g
Degree of Protection II/2
Rated impulse withstand voltage [Uimp] IP20
Emitted interference 850 V
Interference immunity DIN/EN 55011/22, Class A
Weight EN 50081-2
Dimensions (W x H x D) 0.095 kg
Terminations 35 x 90 x 30 mm
Terminal capacities
>Screw terminals
>Flexible with ferrule
Screw terminals
Terminal capacities
>Screw terminals
>Solid
0.2 - 2.5 (AWG22 - 12) mm2
Input voltage 0.2 - 2.5 (AWG22 - 12) mm2
Admissible range
Residual ripple 24 V DC
Mains overvoltage protection 20.4 - 28.8 V DC
Potential isolation
>Input voltage against PE
≦ 5 %
Potential isolation
>Input voltage agaisnt output voltage
Yes
Potential isolation
>Output voltage against PE
Yes
Rated value No
Output current Yes
Rated operational current for specified heat dissipation [In] 24 V DC
Heat dissipation per pole, current-dependent [Pvid] 2.2 A
Equipment heat dissipation, current-dependent [Pvid]
Static heat dissipation, non-current-dependent [Pvs] 0 A
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
+55 °C
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Type of electrical accessory The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Type of mechanical accessory Is the panel builder´s responsibility.
Product Standards Is the panel builder´s responsibility.
UL File No. The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
UL Category Control No.
CSA File No.
CSA Class No. Other
North America Certification Other
Specially designed for North America IEC: see Technical Data; UL508; CSA-C22.2 No. 0-M; CSA-C22.2 No. 142-M; CE marking
Current Limiting Circuit-Breaker E135462
Degree of Protection NRAQ