ECO Compact distribution board, flush mounting, 3-rows, 12 MU, IP40
ECO Compact distribution board, flush mounting, white RAL9003, IP40 degree of protection to IEC/EN 62208, 12 module units, 3-rows, protection class 2, totally insulated, approved for building service distribution boards in accordance with IEC/EN 61439-3 VDE 0660-600-3, enclosure completely made of ABS, for installing switching and protective devices, in accordance with dimension standard DIN 43 880, with an installation depth of 70 mm, AC 400 V, roHs-compliant, consisting of a plastic base with a top hat DIN-rail made of galvanized sheet steel, finger-proof IP2X neutral and protective conductor terminals, knockout cable entries on top and bottom, top with 46-mm device opening, transparent hinged flap flush with the front and featuring open-position latching, operator only with screw closures, top with sealable bottom, including inscription labels.
Basic function | Basic device |
Product function | Installation distribution boards |
Product range | ECO DBO |
Design | Flush mounted |
Installation site | Indoor |
Type of installation | Flush mounting |
Door/Flap | Transparent |
Degree of Protection | IP40 |
Colour | White |
Module rack | Single-rail |
Shroud for protection against accidental contact | Plastic |
Rows [Count] | 3 |
Module units per row | 12 |
Description | IP40 Protection Class II Plastic housing white (RAL 9003) |
Cable entries | Cable entry ribs on top and bottom |
PE and N terminals design | Screw terminals |
PE and N terminals [Number x cross-sectional area] | PE: 3 x (12 x 10) N: 3 x (12 x 10) mm2 |
Equipment supplied | Basic device Device support rails Neutral-/protective conductor terminal |
Standards | EN 62208_x |
RoHS (in accordance with Directive 2002/95/EC of the European Parliament and Council) | conform |
Ambient temperature | -20 - +70 °C |
Degree of Protection | IP40 |
Protection class | II (totally insulated) |
Rated operational voltage [Ue] | 400 V AC |
Rated frequency [f] | 50 Hz |
Material | ABS (plastic) |
Colour | white (RAL 9003) |
Mechanical >Impact resistance |
IK05 |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
850 °C; meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Not relevant to indoor installations. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply to enclosures without lifting aids. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
IK05 |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | IP40 |
10.4 Clearances and creepage distances | Is the panel builder´s responsibility. |
10.5 Protection against electric shock | Protection class 2, therefore not applicable. |
10.6 Incorporation of switching devices and components | Is the panel builder´s responsibility. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Ui = 400 V AC |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
3.75 kV |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | Meets the product standard´s requirements. |
Mounting method | Flush mounted (plaster) |
Number of rows | 3 |
Width in number of modular spacings | 12 |
Type of cover | Door |
Cover model | Closed |
Transparent cover/door | Yes |
Material housing | Plastic |
Height | 550 mm |
Width | 303 mm |
Depth | 98 mm |
Built-in depth | 70 mm |
Internal depth | 90 mm |
DIN-rail | Yes |
With mounting plate | No |
Extension possible | No |
EMC-version | No |
Colour | White |
RAL-number | 9003 |
Degree of protection (IP) | IP40 |
With lock | No |
Type of closure | Other |