SKU: Eaton-284471
Module plate, 2-hole, vertical, 3p, 1250A
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. insulation using NZM4(-4)-XKSA cover or NZM4(-4)-XKP phase isolator necessary. Can be used for: NZM4, N(S)4
Accessories | Module plate |
Description | Two holes |
Number of conductors | 3 pole |
Rated current [In] | ≦ 1250 A |
For use with | NZM4, N(S)4 |
Type of conductor >Cu/Al cable |
Copper cable lugs |
Terminal capacities >flexible |
2 x 95 - 300 mm2 |
AWG/kcmil | 2 x 000 - 600 mm2 |
Cu strip (number of segments x width x segment thickness) | (2 x) 10 x 40 x 1.0 (2 x) 10 x 50 x 1.0 mm2 |
Copper busbar width x thickness [Width] | (2 x) 40 x 10 (2 x) 50 x 10 mm |
Notes | Type contains parts for a terminal located at top or bottom for 3 or 4-pole circuit-breakers. Insulation through cover NZM4(-4)-XKSA or phase isolator NZM4(4)-XKP necessary. |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Suitable for number of poles | 3 |
Product Standards | UL489; CSA-C22.2 No. 5-09; IEC60947, CE marking |
UL File No. | E31593 |
UL Category Control No. | DIHS |
CSA File No. | 22086 |
CSA Class No. | 1432-01 |
North America Certification | UL listed, CSA certified |
Suitable for | Refer to main component information |