284412 NZMH1-A80

Circuit-breaker, 3p, 80A
Circuit-breaker NZM1, 3 pole, Switching capacity 400/415 V 50 Hz( Icu ): 100 kA, Rated current = rated uninterrupted current Rated current = rated uninterrupted current( In = Iu ): 80 A, Installation type: Fixed, Box terminal, Standard/Approval: IEC, Protective function: System and cable protection

Ürün Açıklaması

Circuit-breaker, 3p, 80A
Circuit-breaker NZM1, 3 pole, Switching capacity 400/415 V 50 Hz( Icu ): 100 kA, Rated current = rated uninterrupted current Rated current = rated uninterrupted current( In = Iu ): 80 A, Installation type: Fixed, Box terminal, Standard/Approval: IEC, Protective function: System and cable protection
Product range Circuit-breaker
Protective function System and cable protection
Standard/Approval IEC
Installation type Fixed
Release system Thermomagnetic release
Construction size NZM1
Number of poles 3 pole
Standard equipment Box terminal
400/415 V 50 Hz [Icu ] 100 kA
Rated current = rated uninterrupted current [In = Iu] 80 A
Overload trip [Ir ]
63 - 80 A
Short-circuit releases [Irm ]
>Non-delayed [Ii = In x …]
63 - 80 A
Short-circuit releases [Irm ] 6 - 10
Standards 480 - 800 A
Protection against direct contact IEC/EN 60947
Climatic proofing Finger and back of hand proof to VDE 0106 Part 100
Ambient temperature
>Ambient temperature, storage
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
>Operation
- 40 - + 70 °C
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 -25 - +70 °C
Safe isolation to EN 61140
>Between auxiliary contacts and main contacts
20 (half-sinusoidal shock 20 ms) g
Safe isolation to EN 61140
>between the auxiliary contacts
500 V AC
Mounting position 300 V AC
Direction of incoming supply
Vertical and 90° in all directions
  With XFI earth-fault release:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in unit
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90° right/left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

Degree of protection
>Device
as required
Degree of protection
>Enclosures
In the operating controls area: IP20 (basic degree of protection)
Degree of protection
>Terminations
With insulating surround: IP40
With door coupling rotary handle: IP66
Other technical data (sheet catalogue) Tunnel terminal: IP10
Phase isolator and strip terminal: IP00
Rated current = rated uninterrupted current [In = Iu] Temperature dependency, Derating
Rated surge voltage invariability [Uimp ]
>Main contacts
80 A
Rated surge voltage invariability [Uimp ]
>Auxiliary contacts
6000 V
Rated operational voltage [Ue] 6000 V
Rated operational voltage [Ue] 690 V AC
Overvoltage category/pollution degree 450 V DC
Rated insulation voltage [Ui ]

The following settings are required in order to ensure correct tripping:

The fast-response release will take longer to respond when used for DC applications. Because of this, the setting on the trip block inscription, which is specified for AC currents, must be set to a lower value for DC currents.

DC correction factor for instantaneous release response value:

o NZM1: 1.25

o NZM2: 1.35

o NZM3: 1.45

Example: NZM3 Ie = 500A. Desired DC tripping current: 10 * Ie = 5000A.

Calculation:

• Desired DC value / correction factor = AC setting on trip block

• 5000A / 1.45 = 3448 A ~ 7 * Ie = Value that needs to be set on the trip block

Permitted circuit configurations:

    
Use in unearthed supply systems III/3
Rated short-circuit making capacity [Icm ]
>240 V [Icm ]
690 V
Rated short-circuit making capacity [Icm ]
>400/415 V [Icm ]
≦ 690 V
Rated short-circuit making capacity [Icm ]
>440 V 50/60 Hz [Icm ]
220 kA
Rated short-circuit making capacity [Icm ]
>525 V 50/60 Hz [Icm ]
220 kA
Rated short-circuit making capacity [Icm ]
>690 V 50/60 H [Ic]
74 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>240 V 50/60 Hz [Icu ]
40 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>400/415 V 50/60 Hz [Icu ]
17 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>440 V 50/60 Hz [Icu ]
100 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>525 V 50/60 Hz [Icu ]
100 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>690 V 50/60 Hz [Icu ]
70 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Icu to IEC/EN 60947 test cycle O-t-CO [Icu]
>500 V DC [Icu]
20 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>240 V 50/60 Hz [Ics ]
10 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>400/415 V 50/60 Hz [Ics ]
30 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>440 V 50/60 Hz [Ics ]
100 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>525 V 50/60 Hz [Ics ]
50 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>690 V 50/60 Hz [Ics]
35 kA
Rated short-circuit breaking capacity Icn [Icn ]
>Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics]
>450 V DC [Ics]
10 kA
Rated short-circuit breaking capacity Icn [Icn ] 7.5 kA
Utilization category to IEC/EN 60947-2 30 kA
Lifespan, mechanical(of which max. 50 % trip by shunt/undervoltage release) [Operations] Maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit-breaker.
Lifespan, electrical
>AC-1
>400 V 50/60 Hz [Operations]
A
Lifespan, electrical
>AC-1
>415 V 50/60 Hz [Operations]
20000
Lifespan, electrical
>AC-1
>690 V 50/60 Hz [Operations]
10000
Lifespan, electrical
>DC-1
>450 V DC [Operations]
10000
Lifespan, electrical
>Max. operating frequency
7500
Total break time at short-circuit 10000
Standard equipment 120 Ops/h
Optional accessories < 10 ms
Round copper conductor
>Box terminal
>Solid
Box terminal
Round copper conductor
>Box terminal
>Stranded
Screw connection
Tunnel terminal
connection on rear
Round copper conductor
>Box terminal
1 x (10 - 16)
2 x (6 - 16) mm2
Round copper conductor
>Tunnel terminal
>Solid
1 x (10 - 70) 3)
2 x (6-25) mm2
Round copper conductor
>Tunnel terminal
>Stranded
>1-hole
3) Up to 95 mm² can be connected depending on the cable manufacturer.
Round copper conductor
>Bolt terminal and rear-side connection
>Direct on the switch
>Solid
1 x 16 mm2
Round copper conductor
>Bolt terminal and rear-side connection
>Direct on the switch
>Stranded
1 x (25 - 95) mm2
Round copper conductor
>Bolt terminal and rear-side connection
>Direct on the switch
1 x (10 - 16)
2 x (6 - 16) mm2
Al circular conductor
>Tunnel terminal
>Solid
1 x (10 - 70) 3)
2 x 25 mm2
Al circular conductor
>Tunnel terminal
>Stranded
>Stranded
3) Up to 95 mm² can be connected depending on the cable manufacturer.
Al circular conductor
>Bolt terminal and rear-side connection
>Direct on the switch
>Solid
1 x 16 mm2
Al circular conductor
>Bolt terminal and rear-side connection
>Direct on the switch
>Stranded
1 x (25 - 95) mm2
Cu strip (number of segments x width x segment thickness)
>Box terminal [min.]
1 x (10 - 16)
2 x (10 - 16) mm2
Cu strip (number of segments x width x segment thickness)
>Box terminal [max.]
1 x (25 - 35)
2 x (25 - 35) mm2
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Screw connection
2 x 9 x 0.8 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [min.]
9 x 9 x 0.8 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [max.]
M6
Control cables 12 x 5 mm
Rated operational current for specified heat dissipation [In] 16 x 5 mm
Equipment heat dissipation, current-dependent [Pvid] 1 x (0.75 - 2.5)
2 x (0.75 - 1.5) mm2
Operating ambient temperature min. 80 A
Operating ambient temperature max. 16.32 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+70 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated permanent current Iu Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated voltage The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz 80 A
Overload release current setting 690 - 690 V
Adjustment range short-term delayed short-circuit release 100 kA
Adjustment range undelayed short-circuit release 63 - 80 A
Integrated earth fault protection 0 - 0 A
Type of electrical connection of main circuit 480 - 800 A
Device construction No
Suitable for DIN rail (top hat rail) mounting Frame clamp
DIN rail (top hat rail) mounting optional Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact No
Number of auxiliary contacts as normally open contact Yes
Number of auxiliary contacts as change-over contact 0
With switched-off indicator 0
With under voltage release 0
Number of poles No
Position of connection for main current circuit No
Type of control element 3
Complete device with protection unit Front side
Motor drive integrated Rocker lever
Motor drive optional Yes
Degree of protection (IP) No
Characteristic curve No
Characteristic curve IP20
Characteristic curve 123U177