284403 NZM1-XUHIV20LK110-130AC

Undervoltage release, 110-130VAC +2early N/O
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: for interlocking and load-shedding circuits, as well as for early-make of the undervoltage release in main-switch applications. For use with Emergency-Stop devices in conjunction with emergency-stop button. when the shunt release is energized, accidental contact with the main contacts of the switch during attempts to switch on is safely prevented. Early make of auxiliary contacts on switching on and off (manual operation): approx. 20ms. Cannot be used in conjunction with NZM...-XR.. remote operator. Undervoltage releases cannot be installed simultaneously with NZM..-XHIV.. early-make auxiliary contact or NZM..-XA.. shunt release. Can be used for: NZM1(-4), N(N/O)1(-4)

Ürün Açıklaması

Undervoltage release, 110-130VAC +2early N/O
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: for interlocking and load-shedding circuits, as well as for early-make of the undervoltage release in main-switch applications. For use with Emergency-Stop devices in conjunction with emergency-stop button. when the shunt release is energized, accidental contact with the main contacts of the switch during attempts to switch on is safely prevented. Early make of auxiliary contacts on switching on and off (manual operation): approx. 20ms. Cannot be used in conjunction with NZM...-XR.. remote operator. Undervoltage releases cannot be installed simultaneously with NZM..-XHIV.. early-make auxiliary contact or NZM..-XA.. shunt release. Can be used for: NZM1(-4), N(N/O)1(-4)
Product range Accessories
Accessories Undervoltage release
Accessories Undervoltage release with early-make auxiliary contact
Standard/Approval UL/CSA, IEC
Construction size NZM1
Description Undervoltage release with 2 early-make auxiliary contacts, e.g., for early-make connection of undervoltage release in main switch applications, as well as for interlock and load shedding circuits.
For use with emergency-stop devices in connection with an emergency-stop button.
When the under-voltage trip is switched off, accidental contact with the circuit breaker’s primary contacts is prevented when switched on.
Early make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms
Cannot be used in conjunction with NZM...-XR... remote operator.
Undervoltage releases cannot be installed simultaneously with NZM...-XHIV... early-make auxiliary contact or NZM...-XA... shunt release.
Connection type Coil terminals with 3 m of loose connection cables
Auxiliary contact terminals wired to terminal block
Auxiliary contacts with two separate early-make auxiliary contacts
Rated control voltage [Us] 110 - 130 V 50/60 Hz V
For use with NZM1(-4), N(S)1(-4)
Rated control voltage [Us ]
>AC [Us ]
110-130 V AC
Rated control voltage [Us ]
>Rated control voltage [Us]
110 - 130 V 50/60 Hz V
Operating range
>Drop-out voltage
0.35 - 0.7 x Us
Operating range
>Pick-up voltage [x Uc]
0.85 - 1.1
Power consumption
>AC
>Pick-up AC
1.5 VA
Power consumption
>AC
>Sealing AC
1.5 VA
Power consumption
>DC
>Pick-up DC
0.8 W
Power consumption
>DC
>Sealing DC
0.8 W
Maximum opening delay (response time until opening of the main contacts) 19 ms
Minimum command time 10 - 15 ms
Solid or flexible conductor, with ferrule 1 x (0,75 - 2,5)
2 x (0,75 - 2,5) mm2
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
1 x (18 … 14)
2 x (18 … 14) AWG
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated control supply voltage Us at AC 50HZ The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated control supply voltage Us at AC 60HZ 110 - 130 V
Rated control supply voltage Us at DC 110 - 130 V
Voltage type for actuating 0 - 0 V
Type of electric connection AC
Number of contacts as normally open contact Screw connection
Number of contacts as normally closed contact 2
Number of contacts as change-over contact 0
Delayed 0
Suitable for power circuit breaker No
Suitable for off-load switch Yes
Suitable for motor safety switch Yes
Suitable for overload relay No
Product Standards No
UL File No. UL489; CSA-C22.2 No. 5-09; IEC60947, CE marking
UL Category Control No. E140305
CSA File No. DIHS
CSA Class No. 022086
North America Certification 1437-01