283292 NZM4-XAS14-1600

Adapter set, 1600A, NZM4/NZM14
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from NZM14 to NZM4. Same connections as NZM14. Part no. contains parts for both sides of switch. 3 connection extensions on outlet side. 3 connection extensions on trip block side. 1 long shroud for the outlet side. paper drilling template in the assembly and maintenance instructions. Cannot be combined with module plate (NZM4-XKM..), flat cable terminal (NZM4-XKB), connection width extension (NZM4-XKV..), tunnel terminal (NZM4-XKA), connection on rear (NZM4-XKR) and withdrawable unit (NZM4-XAV..). Can be used for: NZM4, N4

Ürün Açıklaması

Adapter set, 1600A, NZM4/NZM14
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: conversion kit from NZM14 to NZM4. Same connections as NZM14. Part no. contains parts for both sides of switch. 3 connection extensions on outlet side. 3 connection extensions on trip block side. 1 long shroud for the outlet side. paper drilling template in the assembly and maintenance instructions. Cannot be combined with module plate (NZM4-XKM..), flat cable terminal (NZM4-XKB), connection width extension (NZM4-XKV..), tunnel terminal (NZM4-XKA), connection on rear (NZM4-XKR) and withdrawable unit (NZM4-XAV..). Can be used for: NZM4, N4
Accessories Connection adapter set
Number of conductors 3 pole
Rated current [In] ≦ 1600 A
For use with NZM4, N4
Notes

Conversion kit for NZM14 to NZM4. Same connections as NZM14. Part no. contains parts for both sides of switch.

Equipment supplied:

3 connection extensions on outlet side

3 connection extensions on trip block side

1 shroud (upper part) for the outlet side.

2 mounting bracket

2 insulation plates

Paper drilling template in the instruction leaflet (AWA)

Cannot be combined with the module plate (NZM4‐XKM…), flat cable terminal (NZM4‐XKB), connection width extension (NZM4‐XKV…), tunnel terminal (NZM4‐XKA), connection on rear (NZM4‐XKR) and withdrawable unit (NZM4‐XAV…).

10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Suitable for number of poles 3