279411 M22-D4-S

Position pushbutton, RMQ-Titan, Actuators non-flush, momentary, 4-fold, opposing pushbuttons not mechanically interlocked, Bezel: titanium
Position pushbutton, Product range: RMQ-Titan, Single unit, Design: Actuators non-flush, momentary, Description: 4-fold, opposing pushbuttons not mechanically interlocked, Name: No inscription, actuator colour black, Degree of Protection: IP66, Bezel: titanium, Connection to SmartWire-DT: yes, with SWD-RMQ connections, Front dimensions: 55 x 55, Standards: IEC/EN 60947, VDE 0660

Ürün Açıklaması

Position pushbutton, RMQ-Titan, Actuators non-flush, momentary, 4-fold, opposing pushbuttons not mechanically interlocked, Bezel: titanium
Position pushbutton, Product range: RMQ-Titan, Single unit, Design: Actuators non-flush, momentary, Description: 4-fold, opposing pushbuttons not mechanically interlocked, Name: No inscription, actuator colour black, Degree of Protection: IP66, Bezel: titanium, Connection to SmartWire-DT: yes, with SWD-RMQ connections, Front dimensions: 55 x 55, Standards: IEC/EN 60947, VDE 0660
Product range RMQ-Titan
Basic function Pushbuttons
Single unit/Complete unit Single unit
Design Actuators non-flush
Description momentary
Name 4-fold
opposing pushbuttons not mechanically interlocked
Degree of Protection No inscription, actuator colour black
Front ring IP66
Connection to SmartWire-DT Bezel: titanium
Front dimensions yes
with SWD-RMQ connections
Standards 55 x 55
Lifespan, mechanical [Operations] IEC/EN 60947
VDE 0660
Operating frequency [Operations/h] > 0.2 x 106
Actuating force ≦ 3600
Climatic proofing ≦ 5 n
Degree of Protection Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
>Open
IP66
Mounting position -25 - +70 °C
Mechanical shock resistance As required
shipping classification 30
Shock duration 11 ms
Sinusoidal
according to IEC 60068-2-27 g
Rated operational current for specified heat dissipation [In] DNV
GL
LR
Heat dissipation per pole, current-dependent [Pvid] 0000SPC-1830000SPC-1800000SPC-179
Equipment heat dissipation, current-dependent [Pvid] 0 A
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+70 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Please enquire
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Not applicable.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Colour button Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of command positions The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Construction type lens Black
Hole diameter 4
Width opening Round
Height opening 22 mm
Type of button 0 mm
Suitable for illumination 0 mm
With protective cover Flat
Labelled No
Switching function latching No
Spring-return No
With front ring No
Material front ring Yes
Colour front ring Yes
Degree of protection (IP), front side Plastic
Degree of protection (NEMA), front side Chrome
Product Standards IP66
UL File No. 4X
UL Category Control No. IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
CSA File No. E29184
CSA Class No. NKCR
North America Certification 012528
Degree of Protection 3211-03