256790 FAK-R/V/KC02/IY

Palm switch, 2 N/C, emergency switching off, surface mounting
Foot and palm switch, Complete unit, Function: maintained, Description: Pull to release, Emergency stop pushbutton tamper-proof to ISO 13850/EN 418, Contacts N/C = Normally closed: 2 NC, Contacts Notes = safety function, by positive opening to IEC/EN 60947-5-1, Colour Button: Red, Colour enclosure top: Yellow, Colour Enclosure base: Black, Connection to SmartWire-DT: no, Standards: IEC/EN 60947-5-5, VDE 0660, Degree of protection, IEC/EN 60529: IP66, IP67, IP69K, Mounting position: As required

Ürün Açıklaması

Palm switch, 2 N/C, emergency switching off, surface mounting
Foot and palm switch, Complete unit, Function: maintained, Description: Pull to release, Emergency stop pushbutton tamper-proof to ISO 13850/EN 418, Contacts N/C = Normally closed: 2 NC, Contacts Notes = safety function, by positive opening to IEC/EN 60947-5-1, Colour Button: Red, Colour enclosure top: Yellow, Colour Enclosure base: Black, Connection to SmartWire-DT: no, Standards: IEC/EN 60947-5-5, VDE 0660, Degree of protection, IEC/EN 60529: IP66, IP67, IP69K, Mounting position: As required
Product range Foot and palm switches
Basic function Complete devices
Single unit/Complete unit Complete unit
Function maintained
Description Pull to release
Emergency stop pushbutton tamper-proof to ISO 13850/EN 418
N/C = Normally closed 2 NC
Notes = safety function, by positive opening to IEC/EN 60947-5-1
Button Red
enclosure top 116C061
Enclosure base Yellow
Approval 116C064
Connection to SmartWire-DT Black
Standards 116C060
Lifespan, mechanical [Operations] 000Z038116Z028000Z083000Z016
Operating frequency [Operations/h] no
Actuating force IEC/EN 60947-5-5, VDE 0660
Degree of protection, IEC/EN 60529 > 0.1 x 106
Climatic proofing ≦ 600
Ambient temperature
>Open
40 - 60 N
Mounting position IP66, IP67, IP69
Mechanical shock resistance Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Rated operational current for specified heat dissipation [In] -25 - +55 °C
Heat dissipation per pole, current-dependent [Pvid] As required
Equipment heat dissipation, current-dependent [Pvid] > 15
Shock duration 11 ms
Sinusoidal
according to IEC 60068-2-27 g
Static heat dissipation, non-current-dependent [Pvs] 6 A
Heat dissipation capacity [Pdiss] 0.11 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
-25 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
+55 °C
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Please enquire
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Unlocking method Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Colour cap Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of contacts as normally open contact The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of contacts as normally closed contact Pull-release
Switching function latching Red
Spring-return 0
Hole diameter 2
Degree of protection (IP) Yes
Degree of protection (NEMA) No
Product Standards 0 mm
UL File No. IP67/IP69K
UL Category Control No. 4X
CSA File No. IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
CSA Class No. E29184
North America Certification NKCR
Degree of Protection 012528