256285 EASY-NT-150

Connecting cable for networking devices via easyNet, 2xRJ45, 150cm
Connecting cable can be used for easyNet, prefabricated to 150 cm 2 RJ45 plugs at the ends

Ürün Açıklaması

Connecting cable for networking devices via easyNet, 2xRJ45, 150cm
Connecting cable can be used for easyNet, prefabricated to 150 cm 2 RJ45 plugs at the ends
Description Connection cable for XC200 to interface switch
Length 1.5 m
For use with easy800
MFD-…-CP8…
For use with easyNet
Conductor material
Conductor material E-Cu 58 F21 nach DIN 40500 Teil 4
Core Max. 0.49 mm (Cu wire bare 7 x 0.16 mm2)
Stranding 0.60 mm ±0.10 (dielectric polyethylene, halogen free, every two cores paired and twisted: wsbl-bl, wsor-or, wsgn-gn, wsbr-br)
Sheath Four pairs
Rated operational current for specified heat dissipation [In] 4.5 mm ± 0.2 (halogen free casing material, flame retardant (FRNC)) mm2
Heat dissipation per pole, current-dependent [Pvid]
Equipment heat dissipation, current-dependent [Pvid] 0 A
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+55 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Conductor surface Is the panel builder´s responsibility.
Diameter conductor Is the panel builder´s responsibility.
Nominal cross section conductor The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
AWG-size
Conductor category Bare
Number of cores 4.5 mm
Number of stranding elements 0.14 mm²
Stranding element 26
Core insulation material Class 2 = stranded
Specification core insulation 8
Core identification 2
Screen over stranding element Pairs
Stranding Other
Screen over stranding
Longitudinal water blocking cable Colour
Radial water blocking cable None
Protective sheath
Armouring None
Material outer sheath
Specification material outer sheath
Colour outer sheath
Reaction-to-fire class according to EN 13501-6
Smoke development class according to EN 13501-6
Euro class flaming droplets/particles according to EN 13501-6
Euro class acidity according to EN 13501-6 Grey
Halogen free (acc. EN 60754-1/2)
Halogen free (acc. IEC 60754-2)
Flame retardant
Low smoke (acc. EN 61034-2)
Low smoke (acc. IEC 61034-2) Yes
Oil resistant (acc. EN 60811-404)
Oil resistant (acc. IEC 60811-404) No
Insulation integrity in accordance with IEC 60331 No
Circuit integrity Yes
Outer diameter approx.
Min. permitted bending radius, moving application with forced guidance
Min. permitted bending radius, moving application/free movement
Min. permitted bending radius, stationary application/permanent installation
Permitted cable outer temperature during assembling/handling 4.5 mm
Permitted cable outer temperature after assembling without vibration mm
Category mm
NVP value mm
Underground installation -25 - 60 °C
UV resistant -25 - 60 °C
Product Standards 5E
UL File No. 67 %
UL Category Control No. No
CSA File No.
CSA Class No. IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking
North America Certification E135462
Degree of Protection NRAQ