SKU: Eaton-256283
Connecting cable for networking devices via easyNet, 2xRJ45, 30cm
Connecting cable in the easyNet interconnection, prefabricated to 30 cm 2 RJ45 plugs at the ends
Description | Connection cable for XC200 to interface switch |
Length | 0.3 m |
For use with | easy800 MFD-…-CP8… |
For use with | easyNet |
Conductor material | |
Conductor material | E-Cu 58 F21 nach DIN 40500 Teil 4 |
Core | Max. 0.49 mm (Cu wire bare 7 x 0.16 mm2) |
Stranding | 0.60 mm ±0.10 (dielectric polyethylene, halogen free, every two cores paired and twisted: wsbl-bl, wsor-or, wsgn-gn, wsbr-br) |
Sheath | Four pairs |
Rated operational current for specified heat dissipation [In] | 4.5 mm ± 0.2 (halogen free casing material, flame retardant (FRNC)) mm2 |
Heat dissipation per pole, current-dependent [Pvid] | |
Equipment heat dissipation, current-dependent [Pvid] | 0 A |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 0 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | 0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
-25 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
+55 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
|
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Conductor surface | Is the panel builder´s responsibility. |
Diameter conductor | Is the panel builder´s responsibility. |
Nominal cross section conductor | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
AWG-size | |
Conductor category | Bare |
Number of cores | 4.5 mm |
Number of stranding elements | 0.14 mm² |
Stranding element | 26 |
Core insulation material | Class 2 = stranded |
Specification core insulation | 8 |
Core identification | 2 |
Screen over stranding element | Pairs |
Stranding | Other |
Screen over stranding | |
Longitudinal water blocking cable | Colour |
Radial water blocking cable | None |
Protective sheath | |
Armouring | None |
Material outer sheath | |
Specification material outer sheath | |
Colour outer sheath | |
Reaction-to-fire class according to EN 13501-6 | |
Smoke development class according to EN 13501-6 | |
Euro class flaming droplets/particles according to EN 13501-6 | |
Euro class acidity according to EN 13501-6 | Grey |
Halogen free (acc. EN 60754-1/2) | |
Halogen free (acc. IEC 60754-2) | |
Flame retardant | |
Low smoke (acc. EN 61034-2) | |
Low smoke (acc. IEC 61034-2) | Yes |
Oil resistant (acc. EN 60811-404) | |
Oil resistant (acc. IEC 60811-404) | No |
Insulation integrity in accordance with IEC 60331 | No |
Circuit integrity | Yes |
Outer diameter approx. | |
Min. permitted bending radius, moving application with forced guidance | |
Min. permitted bending radius, moving application/free movement | |
Min. permitted bending radius, stationary application/permanent installation | |
Permitted cable outer temperature during assembling/handling | 4.5 mm |
Permitted cable outer temperature after assembling without vibration | mm |
Category | mm |
NVP value | mm |
Underground installation | -25 - 60 °C |
UV resistant | -25 - 60 °C |
Product Standards | 5E |
UL File No. | 67 % |
UL Category Control No. | No |
CSA File No. | |
CSA Class No. | IEC/EN see Technical Data; UL 508; CSA C22.2 No. 142-M1987; CSA C22.2 No. 213-M1987; CE marking |
North America Certification | E135462 |
Degree of Protection | NRAQ |