Ürün Açıklaması

Safety fixing set
Accessories for the control circuit devices program
Accessories General accessories
Basic function accessories Safety fixing set
Mounting depth: For safety relevant operations: Emergency switching off, stop, start, hand-auto, etc.
safe stop also under extreme conditions due to impact shock and vibration
Insulated enclosure to avoid accidental electrical shock
Safe contact monitoring due to mechanical form
Grid dimension 35 x 60 mm
Up to 3 functional elements with front or base fixing as well as screw or Cage Clamp termination
Connection to SmartWire-DT 45 mm
Ambient temperature
>Open
no
shipping classification -25 - +70 °C
Rated operational current for specified heat dissipation [In] DNV
GL
LR
Heat dissipation per pole, current-dependent [Pvid] 0000SPC-1830000SPC-1800000SPC-179
Equipment heat dissipation, current-dependent [Pvid] 0 A
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+70 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Please enquire
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Not applicable.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Type of electrical accessory Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Type of mechanical accessory The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.