236198 PXL-B1,6/2

Miniature circuit breaker (MCB), 1.6 A, 2p, characteristic: B
Miniature circuit breaker (MCB), PXL, 2-pole, tripping characteristic: B, rated current In: 1.6 A, rated switching capacity according to IEC/EN 60898-1: 10 kA, Switchgear for residential and commercial applications

Ürün Açıklaması

Miniature circuit breaker (MCB), 1.6 A, 2p, characteristic: B
Miniature circuit breaker (MCB), PXL, 2-pole, tripping characteristic: B, rated current In: 1.6 A, rated switching capacity according to IEC/EN 60898-1: 10 kA, Switchgear for residential and commercial applications
Basic function Miniature circuit-breakers
Number of poles 2 pole
Tripping characteristic B
Application Switchgear for residential and commercial applications
Rated current [In] 1.6 A
Rated switching capacity according to IEC/EN 60898-1 [Icn] 10 kA
Product range PXL
Rated switching capacity according to IEC/EN 60898-1 [Icn]
Rated operational current for specified heat dissipation [In] 10 kA
Heat dissipation per pole, current-dependent [Pvid]
Equipment heat dissipation, current-dependent [Pvid] 1.6 A
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 4.9 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+75 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
linear, per +1 °C, results in a 0.5% reduction of current carrying capacity
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Release characteristic The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Number of poles (total) Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of protected poles Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated current The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated voltage
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp B
Rated short-circuit breaking capacity Icn EN 60898 at 230 V 2
Rated short-circuit breaking capacity Icn EN 60898 at 400 V 2
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V 1.6 A
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V 400 V
Voltage type 440 V
Frequency 4 kV
Current limiting class 10 kA
Suitable for flush-mounted installation 10 kA
Concurrently switching N-neutral 0 kA
Over voltage category 0 kA
Pollution degree AC
Additional equipment possible 50 - 60 Hz
Width in number of modular spacings 3
Built-in depth No
Degree of protection (IP) No
Ambient temperature during operating 3
Connectable conductor cross section multi-wired 2
Connectable conductor cross section solid-core Yes