SKU: Eaton-231271
AS-Interface module, 2I, 1Q, spring clamp connection
Accessories for the control circuit devices program
Product range | Accessories |
Accessories | AS-Interface |
Basic function accessories | AS-Interface connection |
Fixing | Base fixing for RMQ-Titan |
Front ring | Adapter element for RMQ-Titan AS-Interface information: 2 input bits, 1 output bit – Inputs for 2 contacts – Output for 1 LED element: M22-LED-... |
Connection to SmartWire-DT | Bezel: titanium |
Standards | no |
Radio interference suppression | IEC/EN 60947, DIN EN 50 295 |
Degree of Protection | EN 55011, EN 55022 |
Climatic proofing | IP00 |
Ambient temperature >Open |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mechanical shock resistance | -25 - +55 °C |
Fixing | > 30 Shock duration 11 ms g |
Mounting position | Base fixing for RMQ-Titan |
Rated voltage to AS-Interface Specification | As required |
Connection of the AS interface line | 26.5 - 31.6 V DC |
Power supply | 2 cables on board |
Addressing | Completely from the AS-Interface cable |
Max. total current | Via connection to AS-Interface cable |
AS-Interface | ≦ 40 mA |
Rated operational current when idle (no I, O set) | Protected against polarity reversal |
Status LEDs | 30 mA |
Inputs, protected against short-circuit | POWER AS-Interface cable: green LED on the board ERROR AS-Interface, AS-Interface Master failure: red LED on the board |
Length of connecting cables | 2 (normally 22 V/5 mA) Number |
Outputs, protected against short-circuit | 200 cm |
Voltage range | 1 (normally 19 V/8 mA) Number |
Length of connecting cables | 24 V DC (+10/-15%) V DC |
Profile | 200 cm |
Specification | S-3.A.E |
Addresses | 2.1 |
Rated operational current for specified heat dissipation [In] | 62 Number |
Heat dissipation per pole, current-dependent [Pvid] | 0 A |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 1.3 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | -25 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
+55 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Built-in diameter | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of appliances to build in | 0 mm |
Product Standards | 0 |
UL File No. | IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking |
UL Category Control No. | E29184 |
CSA File No. | NKCR |
CSA Class No. | 012528 |
North America Certification | 3211-03 |