Ürün Açıklaması

ASI-Slave safety, 2I, 1Q, screw connection
Accessories for the control circuit devices program
Product range Accessories
Accessories AS-Interface
Basic function accessories Emergency switching off circuits
Approval 0000SPC-653
Fixing Front fixing for RMQ-Titan
Connection to SmartWire-DT AS-Interface slave
Adapter element for RMQ-Titan
AS-Interface information:
1 dual-channel input, 1 output
Module enclosure for snap fitting on the contact and LED elements:
- Inputs for 2 contact elements: M22-K01 (break)
– Output for 1 LED element: M22-LED-...
Including AS-Interface connector as insulation piercing terminal
Connection of the AS interface line no
Power supply Yellow plug-in terminal as insulation piercing terminal
Fixing Completely from the AS-Interface, cable 26.5 - 31.6 V DC
Addressing Front fixing for RMQ-Titan
Max. total current Via AS-Interface cable
Ambient temperature 45 mA A
Mechanical shock resistance -25 - +55 °C
Degree of Protection 30
Shock duration 11 ms
according to IEC 60068-2-27 g
Climatic proofing IP20
Mounting position Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Standards As required
Inputs EN 50178
EN 50295_x
Outputs 2-channel input (22 V/5 mA) (moduled by code sequence) (2 break contact sets RMQ-Titan M22-K01)
Power AS-Interface cable 1 output, typically 19 V/8 mA, short-circuit proof
Error AS-Interface, failure of AS-Interface master Green LED on the back
Profile Red LED on the back
Rated operational current for specified heat dissipation [In] S-7.B.E
Heat dissipation per pole, current-dependent [Pvid] 0 A
Equipment heat dissipation, current-dependent [Pvid] 0 W
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 1.5 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. -25 °C
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
+70 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Built-in diameter The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of appliances to build in 0 mm
Product Standards 0
UL File No. IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
UL Category Control No. E29184
CSA File No. NKCR
CSA Class No. 012528
North America Certification 3211-03