I/O expansion, For use with easyE4, 24 V DC, Inputs expansion (number) analog: 4, screw terminal
I/O expansion, Supply voltage: 24 V DC, Can be used via easyConnect, Connection type: Screw terminal, Mounting position: Vertical or horizontal, Protection type (IEC/EN 60529, EN50178, VBG 4): IP20, Standards: EN 61000-6-2, EN 61000-6-3, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-30, IEC 60664, IEC 61131-2, EN 61010, EN 50178, cULus per UL 61010, CSA C22.2 No.61010

Ürün Açıklaması

I/O expansion, For use with easyE4, 24 V DC, Inputs expansion (number) analog: 4, screw terminal
I/O expansion, Supply voltage: 24 V DC, Can be used via easyConnect, Connection type: Screw terminal, Mounting position: Vertical or horizontal, Protection type (IEC/EN 60529, EN50178, VBG 4): IP20, Standards: EN 61000-6-2, EN 61000-6-3, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-30, IEC 60664, IEC 61131-2, EN 61010, EN 50178, cULus per UL 61010, CSA C22.2 No.61010
Product range Control relays easyE4
Subrange easyE4 Input/Output expansions with temperature detection
Basic function easyE4 extensions
Description Input/output extension for easyE4 control relay
Analog inputs: 4 with temperature sensors PT100, PT1000 or Ni1000
Screw terminals
Inputs expansion (number)
Pt100, Pt1000, Ni1000 Analog: 4
Display 4
Software
Supply voltage with diagnostic LED
For use with EASYSOFT-SWLIC/easySoft 7
Standards 24 V DC
Approvals
>Approvals
easyE4
Approvals
>certificate
Approvals
>shipping classification
EN 61000-6-2
EN 61000-6-3
IEC 60068-2-6
IEC 60068-2-27
IEC 60068-2-30
IEC 61131-2
EN 61010
EN 50178
Approvals cULus
Dimensions (W x H x D) CE
Weight DNV GL
Mounting 0000SPC-596
Connection type 35.5 x 90 x 58 mm
Screw terminals
>Solid
0.085 kg
Screw terminals
>flexible
Top-hat rail IEC/EN 60715, 35 mm or screw fixing using fixing brackets ZB4-101-GF1 (accessories)
Screw terminals
>Solid or flexible conductor, with ferrule
screw terminal
Screw terminals
>Solid or stranded
Screw terminals
>Standard screwdriver
0.2 - 4 mm2
Screw terminals
>Tightening torque
0.2 - 2.5 mm2
Screw terminals
>Stripping length
0,2 - 2,5 mm2
Operating ambient temperature 22 - 12 AWG
Condensation 0.8 x 3.5 mm
Storage [ϑ] 0.5 - 0.7 Nm
relative humidity 6.5 mm
Air pressure (operation)
Protection type (IEC/EN 60529, EN50178, VBG 4) -25 to 55, cold as per IEC 60068-2-1, heat as per IEC 60068-2-2 °C
Vibrations Take appropriate measures to prevent condensation
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms -40 - +70 °C
Drop to IEC/EN 60068-2-31 [Drop height] in accordance with IEC 60068-2-30, IEC 60068-2-78
5 - 95 %
Free fall, packaged (IEC/EN 60068-2-32) 795 - 1080 hPa
Mounting position
Overvoltage category/pollution degree IP20
Electrostatic discharge (ESD)
>applied standard
In accordance with IEC 60068-2-6
constant amplitude 0.15 mm: 10 - 57
constant acceleration 2 g: 57 - 150 Hz
Electrostatic discharge (ESD)
>Air discharge
18 Impacts
Electrostatic discharge (ESD)
>Contact discharge
50 mm
Electromagnetic fields (RFI) to IEC EN 61000-4-3 0.3 m
Radio interference suppression Vertical or horizontal
Burst
power pulses (Surge) III/2
Immunity to line-conducted interference to (IEC/EN 61000-4-6) according to IEC EN 61000-4-2
Clearance in air and creepage distances 8 kV
Insulation resistance 6 kV
Rated operational voltage [Ue] 0.8 - 1.0 GHz: 10
1.4 - 2 GHz: 3
2.0 - 2.7 GHz: 1 V/m
Permissible range [Ue] EN 61000-6-3 Class B
Residual ripple according to IEC/EN 61000-4-4
Supply cables: 2
Signal cables: 2 kV
Protection against polarity reversal according to IEC/EN 61000-4-5
0.5 kV (supply cables, symmetrical)
1 kV (supply cables, asymmetrical)
Input current 10 V
Voltage dips
Fuse nach EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Power loss [P] in accordance with EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201
Heat dissipation at 24 V DC
Power loss [P] 24 DC (-15/+20%) V
Number 20.4 - 28.8 V DC
Input type resistance sensor ≦ 5 %
Temperature range yes
Potential isolation max. 40 mA at Ue
Resolution digital, scaling per sensor ≤ 10 ms
Measuring principle ≧ 1A (T) A
Accuracy (without electromagnetic compatibility interference) Normally 1 W
Conversion time, analog/digital 1 W
Diagnostics
Cable length 1 W
Static heat dissipation, non-current-dependent [Pvs]
Operating ambient temperature min. 4
Operating ambient temperature max. Platinum sensor Pt100, platinum sensor Pt1000, nickel sensor Ni1000
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Pt100, Pt1000: -100 - +200 (-148 - +392)
Pt100, Pt1000: -100 - +400 (-148 - +752)
Pt100, Pt1000: -100 - +800 (-148 - +1472)
Ni1000: -50 - +100 (-58..+212)
Ni1000: -50 - +250 (-58..+482) °C, (°F)
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
from power supply: no
to the inputs: no
to the expansion units: yes
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
12 Bit (0- 4095)
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Two or three wire per sensor, selectable by connection of sensor
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
1 %
10.2 Strength of materials and parts
>10.2.5 Lifting
250, 1000, 2500, 10000 ms
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Card diagnostic: yes
below lower measurement range: yes
Upper sensor measuring range exceeded: yes
10.2 Strength of materials and parts
>10.2.7 Inscriptions
≦ 30, unshielded m
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances 1 W
10.5 Protection against electric shock -25 °C
10.6 Incorporation of switching devices and components +55 °C
10.7 Internal electrical circuits and connections
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Meets the product standard´s requirements.
Supply voltage AC 50 Hz Meets the product standard´s requirements.
Supply voltage AC 60 Hz Meets the product standard´s requirements.
Supply voltage DC Does not apply, since the entire switchgear needs to be evaluated.
Voltage type of supply voltage Does not apply, since the entire switchgear needs to be evaluated.
Switching current Is the panel builder´s responsibility.
Number of analogue inputs Is the panel builder´s responsibility.
Number of analogue outputs Is the panel builder´s responsibility.
Number of digital inputs Is the panel builder´s responsibility.
Number of digital outputs Is the panel builder´s responsibility.
With relay output The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Number of HW-interfaces industrial Ethernet Is the panel builder´s responsibility.
Number of interfaces PROFINET Is the panel builder´s responsibility.
Number of HW-interfaces RS-232 The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of HW-interfaces RS-422
Number of HW-interfaces RS-485
Number of HW-interfaces serial TTY 0 - 0 V
Number of HW-interfaces USB 0 - 0 V
Number of HW-interfaces parallel 20.4 - 28.8 V
Number of HW-interfaces Wireless DC
Number of HW-interfaces other 0.5 A
With optical interface 4
Supporting protocol for TCP/IP 0
Supporting protocol for PROFIBUS 0
Supporting protocol for CAN 0
Supporting protocol for INTERBUS Yes
Supporting protocol for ASI 0
Supporting protocol for KNX 0
Supporting protocol for MODBUS 0
Supporting protocol for Data-Highway 0
Supporting protocol for DeviceNet 0
Supporting protocol for SUCONET 0
Supporting protocol for LON 0
Supporting protocol for PROFINET IO 0
Supporting protocol for PROFINET CBA 0
Supporting protocol for SERCOS 2
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Radio standard Bluetooth No
Radio standard WLAN 802.11 No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
IO link master No
Redundancy No
With display No
Degree of protection (IP) No
Basic device No
Expandable No
Expansion device No
With timer No
Rail mounting possible No
Wall mounting/direct mounting No
Front build in possible No
Rack-assembly possible No
Suitable for safety functions No
Category according to EN 954-1 No
SIL according to IEC 61508 No
Performance level acc. EN ISO 13849-1 No
Appendant operation agent (Ex ia) No
Appendant operation agent (Ex ib) No
Explosion safety category for gas IP20
Explosion safety category for dust No
Width Yes
Height Yes
Depth No
UL File No. Yes
UL Category Control No. Yes
North America Certification Yes
Degree of Protection No