alt
alt

MSC-DME-12-M17(24VDC)
192761 MSC-DME-12-M17(24VDC)
192761

Doğrudan yolverici, 3 kutuplu, 1,5 - 5,5 kW/400 V/AC3, 100 kA, elektronik koruma, DC işletimli

Doğrudan yolverici, 3 kutuplu, 1,5 - 5,5 kW/400 V/AC3, 100 kA, elektronik koruma, DC işletimli

Basic function DOL starters (complete devices)
Basic device MSC
Notes 0000SPC-571
Connection technique Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Connection to SmartWire-DT Screw terminals
Motor rating [P]
>AC-3
>380 V 400 V 415 V [P]
no
Motor rating [P]
>AC-3
>500 V [P]
Rated operational current
>AC-3
>380 V 400 V 415 V [Ie]
5.5 kW
Rated operational current
>AC-3
>500 V [Ie ]
5.5 kW
Setting range of overload releases [Ir] 11.3 A
Contact sequence 9 A
Actuating voltage
Motor-protective circuit-breakers 3 - 12 A
Contactor 1210SWI-16
DOL starter wiring set

Mechanical connection element and electrical electric contact module
24 V DC
Standards DC
Altitude PKE12/XTU-12 Type
Ambient temperature DILM17-10(...) Part no.
Rated impulse withstand voltage [Uimp] PKZM0-XDM32ME Type
Overvoltage category/pollution degree
Rated operational voltage [Ue] IEC/EN 60947-4-1, VDE 0660
AC-4 cycle operation
>Minimum current flow times
Max. 2000 m
AC-4 cycle operation
>Minimum cut-out periods
-25 - +55
AC-4 cycle operation
>Note
Motor protective circuit breaker PKZM0, PKE 6000 V AC
Operating ambient temperature min. III/3
Operating ambient temperature max. 230 - 415 V
Kind of motor starter 500 (Class 5)
700 (Class 10)
900 (Class 15)
1000 (Class 20) ms
With short-circuit release 500 ms
Rated control supply voltage Us at AC 50HZ In AC-4 cycle operation, going below the minimum current flow time can cause overheating of the load (motor).
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. ms
Rated control supply voltage Us at AC 60HZ
Rated control supply voltage Us at DC PKZM0 motor-protective circuit-breakers, see motor-protective circuit-breakers/PKZM0 product group
DILM contactors, see contactor product group
DILET timing relay, ETR, see contactors, electronic timing relays product group
Voltage type for actuating -25 °C
Rated operation power at AC-3, 230 V, 3-phase +55 °C
Rated operation power at AC-3, 400 V
Rated power, 460 V, 60 Hz, 3-phase
Rated power, 575 V, 60 Hz, 3-phase Direct starter
Rated operation current Ie Yes
Rated operation current at AC-3, 400 V 0 - 0 V
Overload release current setting 0 - 0 V
Rated conditional short-circuit current, type 1, 480 Y/277 V 24 - 24 V
Rated conditional short-circuit current, type 1, 600 Y/347 V DC
Rated conditional short-circuit current, type 2, 230 V 3 kW
Rated conditional short-circuit current, type 2, 400 V 5.5 kW
Number of auxiliary contacts as normally open contact 0 kW
Number of auxiliary contacts as normally closed contact 0 kW
Ambient temperature, upper operating limit 11.3 A
Temperature compensated overload protection 12 A
Release class 8 - 12 A
Type of electrical connection of main circuit 0 A
Type of electrical connection for auxiliary- and control current circuit 0 A
Rail mounting possible 100000 A
With transformer 100000 A
Number of command positions 1
Suitable for emergency stop 0
Coordination class according to IEC 60947-4-3 60 °C
Number of indicator lights Yes
External reset possible Adjustable
With fuse Screw connection
Degree of protection (IP) Screw connection
Degree of protection (NEMA) Yes
Supporting protocol for TCP/IP No
Supporting protocol for PROFIBUS
Supporting protocol for CAN No
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for MODBUS No
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet IP20
Supporting protocol for SUCONET Other
Supporting protocol for LON No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFINET CBA No
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Width No
Height No
Depth No
North America Certification No

Mnelko olarak, endüstriyel otomasyon çözümlerinde güvenilir bir iş ortağı olarak, geniş ürün yelpazesi ile işletmenizin tüm ihtiyaçlarını karşılamaya yönelik kaliteli ve yenilikçi ürünler sunmaktayız. Ürün portföyümüz, modern endüstriyel süreçleri desteklemek amacıyla yüksek performans, dayanıklılık ve verimlilik ilkeleri doğrultusunda tasarlanmış çözümlerden oluşur.
Tüm ürünlerimiz, zorlu çalışma koşullarında dahi maksimum güvenilirlik sunar ve işletmenizin operasyonlarını sorunsuz şekilde sürdürmesine yardımcı olur. Endüstriyel otomasyon, enerji yönetimi, kablolama çözümleri ve daha birçok alanda sunduğumuz ürünler, farklı sektörlerdeki ihtiyaçlara esneklikle uyum sağlar.
Ayrıca, ürünlerimiz sadece kaliteli malzemelerle üretilmiş olup, uluslararası standartlara uygunluk göstermektedir. Müşterilerimize sunduğumuz çözümlerle, operasyonel verimliliklerini artırmalarına ve maliyetlerini optimize etmelerine olanak tanıyoruz. Teknolojik gelişmeleri yakından takip eden firmamız, sürekli olarak yenilikçi ürünler sunarak, müşterilerimizin rekabet avantajı elde etmesine destek vermektedir.
Her bir ürün sayfamızda, teknik detaylar, kullanım alanları ve ürün özelliklerine dair kapsamlı bilgilere ulaşabilirsiniz. Endüstriyel süreçlerinizi güçlendirmek için ihtiyacınız olan tüm ürünleri sitemizden keşfedebilir, sorunsuz bir satın alma deneyimi yaşayabilirsiniz.

Benzer Ürünler

PKE32/XTUCP-36
Eaton
EMT6-DB(230V)
Eaton
PKE65/XTUWCP-36
Eaton
PKE65/XTUCP-65
Eaton
MSC-D-16-M15(230V50HZ)
Eaton
MSC-D-16-M15(24VDC)
Eaton
MSC-D-10-M17(230V50HZ)
Eaton
MSC-D-12-M17(230V50HZ)
Eaton