191090 EU1H-SWD-2XD-1

SWD module for 3-way hydraulic valve IP65
SmartWire-DT devices in protection category IP65 for connection of a hydraulic three-way switch valve. Primary valve connection as per DIN EN 175301-803, connection to second valve coil with M12 connector (A-coded, 4-pin). Automatic address setting, digital outputs 24 V DC 1.6/1.3 A (60/70 °C) and short-circuit protection

Ürün Açıklaması

SWD module for 3-way hydraulic valve IP65
SmartWire-DT devices in protection category IP65 for connection of a hydraulic three-way switch valve. Primary valve connection as per DIN EN 175301-803, connection to second valve coil with M12 connector (A-coded, 4-pin). Automatic address setting, digital outputs 24 V DC 1.6/1.3 A (60/70 °C) and short-circuit protection
Product range SmartWire-DT slave
Basic function Digital modules
Function For connecting digital 3-way switching valves
Short Description with supply
Connection to SmartWire-DT yes
Standards IEC/EN 61131-2
EN 50178_x
Approvals
>Approvals
UL
Dimensions (W x H x D) 44.7 x 77.4 x 51.9 mm
Weight 0.09 kg
Mounting Can be screwed onto valve connector in conformity with DIN EN 175301-803
Mounting position As required
Power supply
>Power loss [P]
2.5 W
Air pressure (operation) 795 - 1080 hPa
Ambient temperature
>Operation [ϑ]
-25 - +70 (observe derating) °C
Ambient temperature
>Storage / Transport [ϑ]
-40 - +85 °C
Relative humidity
>Condensation
permissible
Relative humidity
>Relative humidity, non-condensing (IEC/EN 60068-2-30)
5 - 95 %
Protection type (IEC/EN 60529, EN50178, VBG 4) IP65
Vibrations (IEC/EN 61131-2:2008)
>Constant amplitude 3,5 mm
5 - 8.4 Hz
Vibrations (IEC/EN 61131-2:2008)
>Constant acceleration 1 g
8.4 - 150 Hz
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 30 g/11 ms 9 Impacts
Drop to IEC/EN 60068-2-31 [Drop height] 50 mm
Free fall, packaged (IEC/EN 60068-2-32) 0.3 m
Overvoltage category II
Pollution degree 3
Electrostatic discharge (IEC/EN 61131-2:2008)
>Air discharge (Level 3)
8 kV
Electrostatic discharge (IEC/EN 61131-2:2008)
>Contact discharge (Level 2)
4 kV
Electromagnetic fields (IEC/EN 61131-2:2008)
>80 - 1000 MHz
10 V/m
Electromagnetic fields (IEC/EN 61131-2:2008)
>1.4 - 2 GHz
3 V/m
Electromagnetic fields (IEC/EN 61131-2:2008)
>2 - 2.7 GHz
1 V/m
Radio interference suppression (SmartWire-DT) EN 55011 Class A
Burst (IEC/EN 61131-2:2008, Level 3)
>Supply cable
2 kV
Burst (IEC/EN 61131-2:2008, Level 3)
>SmartWire-DT cables
1 kV
Surge (IEC/EN 61131-2:2008, Level 1)
>Surge power cables
1 kV
Radiated RFI (IEC/EN 61131-2:2008, Level 3) 10 V
Station type SmartWire-DT slave
Setting the baud rate automatic
Baud rate (data transfer speed) maximum125/250/500/1000/2000 kbps
Status SmartWire-DT Green LED
SWD-IN M12 plug (A-keyed), 5 pole
SWD-OUT M12 plug (A-keyed), 5 pole
Current consumption (24V, without sensor and without I/O supply)
>Current consumption (24 V SWD supply)
50 mA
Sensor supply
>Overload and short-circuit proof
yes, with diagnostics
Terminal for I/O sensor
>Connection type
DIN-A valve connector, M12 socket (A-keyed), 4 pole
Quantity 2
Output current 1.6 (at 60°C), 1.3 (at 70°C) A
Overload proof yes, with diagnostics
Maximum switching frequency 1 Hz
Status display outputs yellow LED
Rated operational voltage [UAux] 24 V DC (-15/+20%) V
Permissible range 20.4 - 28.8 V DC
Siemens MPI, (optional) yes
Short-circuit rating Not relevant
Potential isolation Galvanically isolated from the SmartWire-DT network
Outputs to SmartWire-DT Yes
Rated operational current for specified heat dissipation [In] 1.6 A
Equipment heat dissipation, current-dependent [Pvid] 1 W
Static heat dissipation, non-current-dependent [Pvs] 1.5 W
Operating ambient temperature min. -25 °C
Operating ambient temperature max. +70 °C
Degree of Protection IP65
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
UL File No. E205091
North America Certification UL listed
Specially designed for North America No