183031 XNH00-1-A160

NH fuse-switch 1p flange connection M8 max. 95 mm²; mounting plate; NH000 & NH00
NH fuse switch-disconnector 1 pole with M8 flat terminal max. 95 mm²; mounting plate; for NH000 & NH00 fuse-links

Ürün Açıklaması

NH fuse-switch 1p flange connection M8 max. 95 mm²; mounting plate; NH000 & NH00
NH fuse switch-disconnector 1 pole with M8 flat terminal max. 95 mm²; mounting plate; for NH000 & NH00 fuse-links
Basic function Basic device
Number of poles 1 pole
Mounting type DIN rails
Mounting plate
Size 00
Type of connection Flat connection
Rated operational current [Ie] 160 A
Front degree of protection (XNH installed) IP20 (Operating status)
IP2XC (Contact protection)
IP10 (Handle cover open)
Rated operational voltage [Ue ] 690 V AC
Rated operational voltage [Ue] 440 V DC
Rated conditional short-circuit current 120 (500 V)
100 (690 V) kA
Flammability characteristics Self-extinguishing as per UL 94
Description Current paths of electrolytic copper, silver-plated
Successor to 225000
Standards IEC/EN 60947-3
Rated operational voltage [Ue ] 690 V AC
Rated operational voltage [Ue] 440 V DC
Rated operational current [Ie] 160 A
Rated frequency [f] 40 - 60 Hz
Rated insulation voltage [Ui] 800 V AC
Total heat dissipation at Ith (without fuses) [Pv] 9 W
Heat dissipation at 80% (without fuses) [Pv] 5.8 W
Rated impulse withstand voltage [Uimp] 8 kV
Utilization category AC-23B
>Rated operating voltage [Ue]
400 V AC
Utilization category AC-23B
>Rated operating current [Ie]
160 A
Utilization category AC­22B
>Rated operating voltage [Ue]
500 V AC
Utilization category AC­22B
>Rated operating current [Ie]
160 A
Utilization category AC-21B
>Rated operating voltage [Ue]
690 V AC
Utilization category AC-21B
>Rated operating current [Ie]
160 A
Utilization category DC-22B
>Rated operating voltage [Ue]
250 V DC
Utilization category DC-22B
>Rated operating current [Ie]
160 A
Utilization category DC­21B
>Rated operating voltage [Ue]
440 V DC
Utilization category DC­21B
>Rated operating current [Ie]
160 A
Rated conditional short-circuit current 120 (500 V)
100 (690 V) kA
Rated short-time withstand current [Icw] 7 kA
Max. fuse
>Size according to DIN VDE 0636-2
000 / 00
Max. fuse
>Max. permitted power loss per fuse link [Pv]
12 W
Lifespan, electrical [Operations] 300
Front degree of protection (XNH installed) IP20 (Operating status)
IP2XC (Contact protection)
IP10 (Handle cover open)
Ambient temperature -25 - +55 °C
Rated operating mode Permanent operation
Activation Dependent manual activation
Mounting position Vertical, horizontal
Altitude Max. 2000 m
Overvoltage category/pollution degree III/3
RoHS (in accordance with Directive 2002/95/EC of the European Parliament and Council) Yes
Direction of incoming supply as required
Lockable Yes, optional
Sealable Yes, Standard
Material characteristics
>Material
Polyamide
Material characteristics
>Colour
Grey
Flammability characteristics Self-extinguishing as per UL 94
Halogen-free Yes
Voltage test Yes, sliding inspection windows
Lifespan, mechanical [Operations] 1400
Track resistance CTI 600
Heat deflection temperature 125 °C
Flange connection
>Bolt diameter
M8
Flange connection
>Cable lug max. width
25 mm
Flange connection
>Flat busbar
20 x 10 mm
Box terminal
>Stranded
1,5 - 95 Cu mm2
Box terminal
>Copper strip [Number of segments x width x thickness]
9 x 9 x 0,8 mm
Box terminal
>Stranded
1,5 - 50 Cu mm2
Box terminal
>Copper band [Number of segments x width x thickness ]
6 x 9 x 0,8 mm
Clamp-type terminal
>Stranded
10 - 70 Cu/Al mm2
Double clamp-type terminal
>Stranded
- mm2
Rated operational current for specified heat dissipation [In] 160 A
Heat dissipation per pole, current-dependent [Pvid] 3 W
Equipment heat dissipation, current-dependent [Pvid] 9 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Is the panel builder´s responsibility.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Ui = 800 V AC
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Version as main switch No
Version as safety switch No
Max. rated operation voltage Ue AC 690 V
Rated permanent current Iu 160 A
Rated operation power at AC-23, 400 V 0 kW
Conditioned rated short-circuit current Iq 120 kA
Rated short-time withstand current lcw 7 kA
Suitable for fuses NH00
Number of poles 1
With error protection No
Type of electrical connection of main circuit Screw connection
Cable entry Other
Equipped with connectors No
Suitable for ground mounting Yes
Suitable for front mounting 4-hole No
Suitable for busbar mounting No
Type of control element Cover grip
Position control element Front side
Motor drive optional No
Motor drive integrated No
Version as emergency stop installation No
Degree of protection (IP), front side Other