174762 SWD4-M6LR5-2S

SmartWire-DT round cable IP67, 0.6 meters, 5-pole, Prefabricated with M12 plug and M12 socket
5 pole SmartWire-DT round cable with IP67 degree of protection 0.6 m long, prefabricated with M12 plug and M12 socket

Ürün Açıklaması

SmartWire-DT round cable IP67, 0.6 meters, 5-pole, Prefabricated with M12 plug and M12 socket
5 pole SmartWire-DT round cable with IP67 degree of protection 0.6 m long, prefabricated with M12 plug and M12 socket
Product range SmartWire-DT accessories
Basic function SWD round cable
Function For connecting peripheral SmartWire-DT cards
Description 5 pole
prefabricated with M12 socket and M12 plug, A-keyed
Length 0.6 m
Note regarding length 1 off
Connection to SmartWire-DT yes
For use with EU1…-SWD…
EU2…-SWD…
EU6…-SWD…
EU8…-SWD-…
Protection type (IEC/EN 60529, EN50178, VBG 4) IP67
Approvals UL
CSA
Protection type (IEC/EN 60529, EN50178, VBG 4) IP67
Operating ambient temperature (IEC 60068-2)
>Operating ambient temperature max.
+70 °C
Condensation permissible
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. -25 °C
Operating ambient temperature max. +70 °C
Degree of Protection IP67
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Conductor surface Bare
Diameter conductor 1.5 mm
Nominal cross section conductor 0.5 mm²
AWG-size 20
Conductor category Class 2 = stranded
Number of cores 5
Number of stranding elements 5
Stranding element Pairs
Core insulation material Other
Specification core insulation Other
Core identification Colour
Screen over stranding element Foil
Stranding Bundle
Screen over stranding None
Longitudinal water blocking cable Yes
Radial water blocking cable Yes
Protective sheath Other
Armouring No
Material outer sheath Polyvinyl chloride (PVC)
Specification material outer sheath Polypropylene
Colour outer sheath Green
Reaction-to-fire class according to EN 13501-6 None
Smoke development class according to EN 13501-6 None
Euro class flaming droplets/particles according to EN 13501-6 None
Euro class acidity according to EN 13501-6 None
Halogen free (acc. EN 60754-1/2) No
Halogen free (acc. IEC 60754-2) No
Flame retardant In accordance with EN 60332-1-2
Low smoke (acc. EN 61034-2) No
Low smoke (acc. IEC 61034-2) No
Oil resistant (acc. EN 60811-404) Yes
Oil resistant (acc. IEC 60811-404) Yes
Insulation integrity in accordance with IEC 60331 No
Circuit integrity No
Outer diameter approx. 5.6 mm
Min. permitted bending radius, moving application with forced guidance mm
Min. permitted bending radius, moving application/free movement mm
Min. permitted bending radius, stationary application/permanent installation 34 mm
Permitted cable outer temperature during assembling/handling -40 - 80 °C
Permitted cable outer temperature after assembling without vibration -40 - 80 °C
Category Other
NVP value 66.5 %
Underground installation No
UV resistant Yes
UL File No. E149111
North America Certification UL listed, CSA certified
Specially designed for North America No