SKU: Eaton-174762
SmartWire-DT round cable IP67, 0.6 meters, 5-pole, Prefabricated with M12 plug and M12 socket
5 pole SmartWire-DT round cable with IP67 degree of protection 0.6 m long, prefabricated with M12 plug and M12 socket
Product range | SmartWire-DT accessories |
Basic function | SWD round cable |
Function | For connecting peripheral SmartWire-DT cards |
Description | 5 pole prefabricated with M12 socket and M12 plug, A-keyed |
Length | 0.6 m |
Note regarding length | 1 off |
Connection to SmartWire-DT | yes |
For use with | EU1…-SWD… EU2…-SWD… EU6…-SWD… EU8…-SWD-… |
Protection type (IEC/EN 60529, EN50178, VBG 4) | IP67 |
Approvals | UL CSA |
Protection type (IEC/EN 60529, EN50178, VBG 4) | IP67 |
Operating ambient temperature (IEC 60068-2) >Operating ambient temperature max. |
+70 °C |
Condensation | permissible |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 0 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +70 °C |
Degree of Protection | IP67 |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Conductor surface | Bare |
Diameter conductor | 1.5 mm |
Nominal cross section conductor | 0.5 mm² |
AWG-size | 20 |
Conductor category | Class 2 = stranded |
Number of cores | 5 |
Number of stranding elements | 5 |
Stranding element | Pairs |
Core insulation material | Other |
Specification core insulation | Other |
Core identification | Colour |
Screen over stranding element | Foil |
Stranding | Bundle |
Screen over stranding | None |
Longitudinal water blocking cable | Yes |
Radial water blocking cable | Yes |
Protective sheath | Other |
Armouring | No |
Material outer sheath | Polyvinyl chloride (PVC) |
Specification material outer sheath | Polypropylene |
Colour outer sheath | Green |
Reaction-to-fire class according to EN 13501-6 | None |
Smoke development class according to EN 13501-6 | None |
Euro class flaming droplets/particles according to EN 13501-6 | None |
Euro class acidity according to EN 13501-6 | None |
Halogen free (acc. EN 60754-1/2) | No |
Halogen free (acc. IEC 60754-2) | No |
Flame retardant | In accordance with EN 60332-1-2 |
Low smoke (acc. EN 61034-2) | No |
Low smoke (acc. IEC 61034-2) | No |
Oil resistant (acc. EN 60811-404) | Yes |
Oil resistant (acc. IEC 60811-404) | Yes |
Insulation integrity in accordance with IEC 60331 | No |
Circuit integrity | No |
Outer diameter approx. | 5.6 mm |
Min. permitted bending radius, moving application with forced guidance | mm |
Min. permitted bending radius, moving application/free movement | mm |
Min. permitted bending radius, stationary application/permanent installation | 34 mm |
Permitted cable outer temperature during assembling/handling | -40 - 80 °C |
Permitted cable outer temperature after assembling without vibration | -40 - 80 °C |
Category | Other |
NVP value | 66.5 % |
Underground installation | No |
UV resistant | Yes |
UL File No. | E149111 |
North America Certification | UL listed, CSA certified |
Specially designed for North America | No |