169872 S811+U36P3S

Soft starter, 361 A, 200 - 600 V AC, Us= 24 V DC, with control unit and pump algorithm, Frame size U
Soft starter, Description: With internal bypass contacts, Function: Soft starter for three-phase loads, with control unit and pump algorithm, Mains supply voltage (50/60 Hz): ULN= 200 - 600 V AC, Supply voltage: Us= 24 V DC, Control voltage: UC= 24 V DC, Assigned motor rating (Standard connection, In-Line) at 400 V, 50 Hz: P= 200 kW, at 460 V, 60 Hz: P= 300 HP, Rated operational current AC-53: Ie= 361 A, Rated operational current AC-53, In-Delta: Ie= 623 A, Startup class: CLASS 10 (star-delta replacement), CLASS 20 (heavy starting duty 3 x Ie for 45 s), CLASS 30 (6 x Ie for 30 s), Rated operational voltage: Ue= 200 V, 230 V, 400 V, 480 V, 600 V, Connection to SmartWire-DT: no, Frame size: U, Ordering information: Terminal blocks for the terminals are required for frame sizes T, U, and V -> Accessories, Standards: IEC/EN 60947-4-2, UL 508, CSA22.2-14-1995, GB14048

Ürün Açıklaması

Soft starter, 361 A, 200 - 600 V AC, Us= 24 V DC, with control unit and pump algorithm, Frame size U
Soft starter, Description: With internal bypass contacts, Function: Soft starter for three-phase loads, with control unit and pump algorithm, Mains supply voltage (50/60 Hz): ULN= 200 - 600 V AC, Supply voltage: Us= 24 V DC, Control voltage: UC= 24 V DC, Assigned motor rating (Standard connection, In-Line) at 400 V, 50 Hz: P= 200 kW, at 460 V, 60 Hz: P= 300 HP, Rated operational current AC-53: Ie= 361 A, Rated operational current AC-53, In-Delta: Ie= 623 A, Startup class: CLASS 10 (star-delta replacement), CLASS 20 (heavy starting duty 3 x Ie for 45 s), CLASS 30 (6 x Ie for 30 s), Rated operational voltage: Ue= 200 V, 230 V, 400 V, 480 V, 600 V, Connection to SmartWire-DT: no, Frame size: U, Ordering information: Terminal blocks for the terminals are required for frame sizes T, U, and V -> Accessories, Standards: IEC/EN 60947-4-2, UL 508, CSA22.2-14-1995, GB14048
Description With internal bypass contacts
Function Soft starter for three-phase loads, with control unit and pump algorithm
Mains supply voltage (50/60 Hz) [ULN] 200 - 600 V AC
Supply voltage [Us] 24 V DC
Control voltage [UC] 24 V DC
at 400 V, 50 Hz [P]
at 460 V, 60 Hz [P] 200 kW
AC-53 [Ie] 300 HP
AC-53, In-Delta [Ie]
Startup class 361 A
Rated operational voltage [Ue] 623 A
Connection to SmartWire-DT CLASS 10 (star-delta replacement)
CLASS 20 (heavy starting duty 3 x Ie for 45 s)
CLASS 30 (6 x Ie for 30 s)
Frame size 200 V
230 V
400 V
480 V
600 V
Ordering information no
Standards U
Approvals Terminal blocks for the terminals are required for frame sizes T, U, and V -> Accessories
Approvals
Climatic proofing IEC/EN 60947-4-2
UL 508
CSA22.2-14-1995
GB14048
Ambient temperature
>Operation [ϑ]
CE
Ambient temperature
>Storage [ϑ]
UL
CSA
C-Tick
CCC
Altitude Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-10
Mounting position -30 - +50 °C
Degree of protection
>Degree of Protection
-50 - +70 °C
Degree of protection
>Integrated
0 - 2000 m, above that each 100 m 0.5% Derating m
Protection against direct contact As required
Overvoltage category/pollution degree IP20 (terminals IP00)
Shock resistance An IP20 degree of protection can be achieved on all sides by using optional terminal covers SS-IP20-TU.
Radio interference level (IEC/EN 55011) Finger- and back-of-hand proof
Static heat dissipation, non-current-dependent [Pvs] II/3
Weight 15 g
Rated operating voltage [Ue] A
Supply frequency [fLN] 76 W
Rated operational current [Ie ]
>AC-53, In-Delta [Ie]
18.6 kg
Rated operational current [Ie ]
>AC-53 [Ie]
Assigned motor rating (Standard connection, In-Line)
>at 230 V, 50 Hz [P]
200 - 600 V AC
Assigned motor rating (Standard connection, In-Line)
>at 400 V, 50 Hz [P]
50/60 Hz
Assigned motor rating (Standard connection, In-Line)
>at 500 V, 50 Hz [P]
623 A
Assigned motor rating (Standard connection, In-Line)
>at 200 V, 60 Hz [P]
361 A
Assigned motor rating (Standard connection, In-Line)
>at 230 V, 60 Hz [P]
110 kW
Assigned motor rating (Standard connection, In-Line)
>at 460 V, 60 Hz [P]
200 kW
Assigned motor rating (Standard connection, In-Line)
>at 600 V, 60 Hz [P]
250 kW
Assigned motor rating (delta connection)
>at 230 V, 50 Hz [P]
125 HP
Assigned motor rating (delta connection)
>at 400 V, 50 Hz [P]
125 HP
Assigned motor rating (delta connection)
>at 500 V, 50 Hz [P]
300 HP
Assigned motor rating (delta connection)
>at 230 V, 60 Hz
350 HP
Assigned motor rating (delta connection)
>at 480 V, 60 Hz
200 kW
Assigned motor rating (delta connection)
>at 600 V, 60 Hz [P]
315 kW
Overload cycle to IEC/EN 60947-4-2
>AC-53a
450 kW
Overload cycle to IEC/EN 60947-4-2
>Internal bypass contacts
250 HP
Short-circuit rating
>Type “1” coordination
500 HP
Cable lengths
>Solid
600 HP
Cable lengths
>Flexible with ferrule
360 A: AC-53a: 4.0 - 32: 99 - 3
Cable lengths
>Stranded
Cable lengths
>Solid or stranded
NZMN3-S400
Control cables
>Solid
Control cables
>Flexible with ferrule
1 x (70 - 240)
2 x (25 - 240) mm2
Control cables
>Stranded
1 x (70 - 240)
2 x (25 - 240) mm2
Control cables
>Solid or stranded
1 x (70 - 150)
2 x (25 - 240) mm2
Control cables
>Tightening torque
1 x (4 - 500 kcmil)
2 x (4 - 500 kcmil) AWG
Control cables
>Screwdriver
1 x (2.5 - 4)
2 x (1.0 - 2.5) mm2
Digital inputs
>Control voltage
>DC-operated
1 x (2.5 - 4)
2 x (1.0 - 2.5) mm2
Digital inputs
>Current consumption 24 V
>External 24 V
1 x (2.5 - 4)
2 x (1.0 - 2.5) mm2
Digital inputs
>Current consumption 24 V
>External 24 V (no-load)
19 x (12 - 14)
2 x (12 - 14) AWG
Digital inputs
>Pick-up voltage
>DC-operated
0.4 Nm
Digital inputs
>Drop-out voltage [x Us ]
>DC operated
>Drop-out voltage, DC-operated, max.
0,6 x 3,5 mm
Digital inputs
>Pick-up time
>DC operated
Digital inputs
>Drop-out time
>DC operated
24 V DC +10 %/- 10 % V DC
Regulator supply
>Voltage [Us]
150 mA
Regulator supply
>Current consumption [Ie]
100 mA
Regulator supply
>Current consumption at peak performance (close bypass) at 24 V DC [IPeak]
21.6 - 26.4 V DC
Regulator supply
>Notes
3 V DC
Analog inputs
>Number of current inputs
100 ms
Analog inputs
>Current input
100 ms
Relay outputs
>Number
24 V DC +10 %/- 10 % V
Relay outputs
>of which programmable
1000 mA
Relay outputs
>Voltage range
10/150 A/ms
Relay outputs
>AC-11 current range
External supply voltage
Ramp times
>Acceleration
>Ramp time, max.
1
Ramp times
>Deceleration
4 - 20 mA
Start voltage (= turn-off voltage)
>Start voltage, max.
2
Start pedestal
>Start voltage, max.
2
Kickstart
>Voltage
>Kickstart voltage, max.
120 V AC/DC V AC
Kickstart
>Duration
>50 Hz
>Kickstart Duration 50 Hz max.
3 A, AC-11 A
Kickstart
>Duration
>60 Hz
>Kickstart Duration 60 Hz max.
Fields of application
>Fields of application
360 s
Fields of application
>3-phase motors
0 - 120 s
Fast switching (semiconductor contactor) 85 %
Soft start function 85 %
Reversing starter 100 %
Suppression of closing transients 2000 ms
Current limitation 2000 ms
Overload monitoring Soft starting of three-phase asynchronous motors
Underload monitoring
Fault memory
Suppression of DC components for motors - (minimum ramp time 1s)
Potential isolation between power and control sections
Communication Interfaces External solution required (reversing contactor)
Rated operational current for specified heat dissipation [In]
Heat dissipation per pole, current-dependent [Pvid]
Equipment heat dissipation, current-dependent [Pvid]
Static heat dissipation, non-current-dependent [Pvs]
Heat dissipation capacity [Pdiss] 10 Faults
Operating ambient temperature min.
Operating ambient temperature max.
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Modbus RTU
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
361 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
76 W
10.2 Strength of materials and parts
>10.2.5 Lifting
76 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
0 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
-30 °C
10.3 Degree of protection of ASSEMBLIES +50 °C
10.4 Clearances and creepage distances
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Rated operation current Ie at 40 °C Tu Does not apply, since the entire switchgear needs to be evaluated.
Rated operating voltage Ue Is the panel builder´s responsibility.
Rated power three-phase motor, inline, at 230 V Is the panel builder´s responsibility.
Rated power three-phase motor, inline, at 400 V Is the panel builder´s responsibility.
Rated power three-phase motor, inside delta, at 230 V Is the panel builder´s responsibility.
Rated power three-phase motor, inside delta, at 400 V Is the panel builder´s responsibility.
Function The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Internal bypass Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
With display Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Torque control The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated surrounding temperature without derating
Rated control supply voltage Us at AC 50HZ
Rated control supply voltage Us at AC 60HZ 360 A
Rated control supply voltage Us at DC 200 - 600 V
Voltage type for actuating 110 kW
Integrated motor overload protection 200 kW
Release class 200 kW
Degree of protection (IP) 315 kW
Degree of protection (NEMA) Single direction
Product Standards Yes
UL File No. Yes
UL Category Control No. No
CSA File No. 50 °C
CSA Class No. 0 - 0 V
North America Certification 0 - 0 V
Suitable for 24 - 24 V
Max. Voltage Rating DC
Degree of Protection Yes