SKU: Eaton-169033
Expansion for DC1 variable frequency drives (230 V IN)
Coupling module, Subrange: Coupling module, Description: 230-V-AC input (electrically isolated), for 4 digital inputs, For connecting to the control signal terminals on the DC1, For use with: DC1
Subrange | Coupling module |
Description | 230-V-AC input (electrically isolated) for 4 digital inputs For connecting to the control signal terminals on the DC1 |
For use with | DC1 |
Operating ambient temperature min. | |
Operating ambient temperature max. | -10 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
+50 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
|
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Type of accessory | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Product Standards | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
UL File No. | |
UL Category Control No. | |
CSA File No. | Other |
North America Certification | UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking |
Specially designed for North America | E172143 |
Suitable for | NMMS, NMMS7 |
Max. Voltage Rating | UL report applies to both US and Canada |
Degree of Protection | UL listed, certified by UL for use in Canada |