SKU: Eaton-140160
Base module block XI/ON, screw, 6 connection levels, con. to C rail
Rack, XI/ON block base modules, Connection levels: 6 connection levels, Connection technique: Screw terminals, for Block module, Connection to C rail, Degree of Protection: IP20, For use with: XN-32DO-24VDC-0.5A-P, Standards: EN 61000-6-2, EN 61000-6-4, EN 61131-2
Function | XI/ON block base modules |
Connection levels | 6 connection levels |
Connection technique | Screw terminals |
Function | for Block module |
Short Description | Connection to C rail |
For use with | XN-32DO-24VDC-0.5A-P |
Standards | |
Potential isolation | EN 61000-6-2 EN 61000-6-4 EN 61131-2 |
Ambient temperature | Yes, through optocoupler |
Relative humidity | 0 - +55 °C |
Harmful gases | 5 - 95 % (indoor), Level RH-2, no condensation (for storage at 45°C) |
Vibration resistance, operating conditions | SO2: 10 (rel. humidity < 75%, no condensation) H2S: 1.0 (rel. humidity < 75 %,no condensation) ppm |
Mechanical shock resistance | according to IEC/EN 60068-2-6 |
Continuous shock resistance (IEC/EN 60068-2-29) | according to IEC 60068-2-27 g |
Drop and topple | According to IEC 60068-2-29 |
Degree of Protection | According to IEC 60068-2-31, free fall according to IEC 60068-2-32 |
Electromagnetic compatibility (EMC) >ESD [Air/contact discharge] |
IP20 |
Electromagnetic compatibility (EMC) >Electromagnetic fields [(0.08…1) / (1,4…2) / (2…2,7) GHz ] |
EN 61000-4-2 kV |
Electromagnetic compatibility (EMC) >Burst |
EN 61100-4-2 V/m |
Electromagnetic compatibility (EMC) >Surge |
EN 61100-4-4 |
Electromagnetic compatibility (EMC) >Radiated RFI |
EN 61100-4-5 |
Electromagnetic compatibility (EMC) >Emitted interference (radiated, high frequency) [(30...230 MHz) / (230...1000 MHz)] |
EN 61100-4-6 V |
Electromagnetic compatibility (EMC) >Voltage fluctuations/voltage dips |
EN 55016-2-3 dB |
Electromagnetic compatibility (EMC) >Type test |
EN 61131-2 |
Approvals | to EN 61131-2 |
Other technical data (sheet catalogue) | CE, cUL (where required in process) |
Rated data | Technical Data |
Connection design in TOP direction | |
Stripping length | according to VDE 0611 Part 1/8.92 / IEC/EN 60947-7-1 |
Clamping range | Spring-loaded/screw terminal |
Connectable conductors >"e" solid H07V-U |
8 mm |
Connectable conductors >"f" flexible H 07V-K |
max. 0.5 - 2.5 mm2 |
Connectable conductors >"f" with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) |
0.5 - 2.5 mm2 |
Connectable conductors >"f" with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) |
0.5 - 1.5 mm2 |
Gauge pin IEC/EN 60947-1 | 0.5 - 1.5 mm2 |
Rated operational current for specified heat dissipation [In] | 0.5 - 1.5 mm2 |
Heat dissipation per pole, current-dependent [Pvid] | A1 |
Equipment heat dissipation, current-dependent [Pvid] | |
Static heat dissipation, non-current-dependent [Pvs] | 0 A |
Heat dissipation capacity [Pdiss] | 0 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | 0 W |
Degree of Protection | 0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
+55 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
IP20 |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
|
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | Is the panel builder´s responsibility. |
With integrated power supply | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Input voltage at AC 50 Hz | Is the panel builder´s responsibility. |
Input voltage at AC 60 Hz | Is the panel builder´s responsibility. |
Input voltage at DC | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Type of voltage (input voltage) | |
Max. input current AC 50 Hz | |
Max. input current AC 60 Hz | No |
Max. input current DC | 0 - 0 V |
Output voltage at AC 50 Hz | 0 - 0 V |
Output voltage at AC 60 Hz | 0 - 0 V |
Output voltage at DC | DC |
Type of output voltage | 0 A |
Max. output current AC 50 Hz | 0 A |
Max. output current AC 60 Hz | 0 A |
Max. output current DC | 0 - 0 V |
System accessory | 0 - 0 V |
Number of slots | 0 - 0 V |
With pluggable modules, digital I/O | DC |
With pluggable modules, analogue I/O | 0 A |
With pluggable modules, communication modules | 0 A |
With pluggable modules, function and technology modules | 0 A |
With pluggable modules, central modules | Yes |
With pluggable modules, others | 1 |
Rail mounting possible | Yes |
Wall mounting/direct mounting | No |
Front build in possible | No |
Rack-assembly possible | No |
Suitable for safety functions | Yes |
Category according to EN 954-1 | No |
SIL according to IEC 61508 | Yes |
Performance level acc. EN ISO 13849-1 | No |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | No |
Explosion safety category for gas | No |
Explosion safety category for dust | |
Width | None |
Height | None |
Depth | No |
Product Standards | No |
UL File No. | None |
UL Category Control No. | None |
CSA File No. | 12.6 mm |
CSA Class No. | 154.5 mm |
North America Certification | 49.9 mm |
Specially designed for North America | UL 508; CSA-C22.2 No. 142; |
Current Limiting Circuit-Breaker | E205091 |
Degree of Protection | NRAQ, NRAQ7 |