SKU: Eaton-140153
Serial interface module XI/ON, SSI
The XI/ON standard I/O system offers the right I/O solution for every application due to its great modularity and large variety of functions. Pluggable modules, hot-swapping of modules, wiring on the basic module screw or tension spring, modules´ mechanical coding. The standard gateways support the CANopen bus systems, PROFIBUS-DP deviceNet and Ethernet.
Function | XI/ON technology modules |
Short Description | Connection of SSI encoders up to max. 32-bit. Transmission rate selectable up to 1MBit/s |
For use with | XN-S4T-SBBS XN-S4S-SBBS |
Rated operational current for specified heat dissipation [In] | |
Heat dissipation per pole, current-dependent [Pvid] | 0 A |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 1 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | 0 °C |
Degree of Protection | +55 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
IP20 |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
|
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.13 Mechanical function | Is the panel builder´s responsibility. |
Supply voltage AC 50 Hz | Is the panel builder´s responsibility. |
Supply voltage AC 60 Hz | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Supply voltage DC | |
Voltage type of supply voltage | |
Supporting protocol for TCP/IP | 0 - 0 V |
Supporting protocol for PROFIBUS | 0 - 0 V |
Supporting protocol for CAN | 18 - 30 V |
Supporting protocol for INTERBUS | DC |
Supporting protocol for ASI | No |
Supporting protocol for KNX | No |
Supporting protocol for MODBUS | No |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for LON | No |
Supporting protocol for SERCOS | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFINET CBA | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for other bus systems | No |
Radio standard Bluetooth | No |
Radio standard WLAN 802.11 | No |
Radio standard GPRS | No |
Radio standard GSM | No |
Radio standard UMTS | No |
IO link master | No |
System accessory | No |
Degree of protection (IP) | No |
With potential separation | No |
Fieldbus connection over separate bus coupler possible | No |
Rail mounting possible | Yes |
Wall mounting/direct mounting | IP20 |
Front build in possible | Yes |
Rack-assembly possible | Yes |
Suitable for safety functions | Yes |
Category according to EN 954-1 | No |
SIL according to IEC 61508 | No |
Performance level acc. EN ISO 13849-1 | No |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | |
Explosion safety category for gas | None |
Explosion safety category for dust | None |
Width | No |
Height | No |
Depth | None |
Product Standards | None |
UL File No. | 12.6 mm |
UL Category Control No. | 74.1 mm |
CSA File No. | 55.4 mm |
CSA Class No. | UL 508; CSA-C22.2 No. 142; IEC/EN 6113-2; CE marking |
North America Certification | E205091 |
Specially designed for North America | NRAQ, NRAQ7 |
Current Limiting Circuit-Breaker | UL report applies to both US and Canada |
Degree of Protection | 2252-01, 2252-81 |
Link to sheet catalogue | UL recognized, certified by UL for use in Canada |