140064 XN-1AI-U(-10/0...+10VDC)

Analog input card XI/ON, 24 V DC, 1AI (0-10V, +-10V)
The XI/ON standard I/O system offers the right I/O solution for every application due to its great modularity and large variety of functions. Pluggable modules, hot-swapping of modules, wiring on the basic module screw or tension spring, modules´ mechanical coding. The standard gateways support the CANopen bus systems, PROFIBUS-DP deviceNet and Ethernet.

Ürün Açıklaması

Analog input card XI/ON, 24 V DC, 1AI (0-10V, +-10V)
The XI/ON standard I/O system offers the right I/O solution for every application due to its great modularity and large variety of functions. Pluggable modules, hot-swapping of modules, wiring on the basic module screw or tension spring, modules´ mechanical coding. The standard gateways support the CANopen bus systems, PROFIBUS-DP deviceNet and Ethernet.
Function XI/ON I/O modules
Function XN Slice module
Short Description 1 Analog input
-10/0 to +10 V DC
For use with XN-S3T-SBB
XN-S3S-SBB
XN-S4T-SBBS
XN-S4S-SBBS
Standards
Potential isolation EN 61000-6-2
EN 61000-6-4
EN 61131-2
Ambient temperature
>Ambient temperature, operation
Yes, through optocoupler
Ambient temperature
>Storage, transport [ϑ]
0 - +55 °C
Relative humidity
>Relative humidity
-25 - +85 °C
Ambient conditions, mechanical
>Degree of Protection
5 - 95 % (indoor), Level RH-2, no condensation (for storage at 45°C)
Ambient conditions, mechanical
>Harmful gases
IP20
Vibration resistance, operating conditions SO2: 10 (rel. humidity < 75%, no condensation)
H2S: 1.0 (rel. humidity < 75 %,no condensation) ppm
Mechanical shock resistance according to IEC/EN 60068-2-6
Continuous shock resistance (IEC/EN 60068-2-29) according to IEC 60068-2-27 g
Drop and topple According to IEC 60068-2-29
Electromagnetic compatibility (EMC)
>ESD [Air/contact discharge]
According to IEC 60068-2-31, free fall according to IEC 60068-2-32
Electromagnetic compatibility (EMC)
>Electromagnetic fields [(0.08…1) / (1,4…2) / (2…2,7) GHz ]
EN 61000-4-2 kV
Electromagnetic compatibility (EMC)
>Burst
EN 61100-4-2 V/m
Electromagnetic compatibility (EMC)
>Surge
EN 61100-4-4
Electromagnetic compatibility (EMC)
>Radiated RFI
EN 61100-4-5
Electromagnetic compatibility (EMC)
>Emitted interference (radiated, high frequency) [(30...230 MHz) / (230...1000 MHz)]
EN 61100-4-6 V
Electromagnetic compatibility (EMC)
>Voltage fluctuations/voltage dips
EN 55016-2-3 dB
Electromagnetic compatibility (EMC)
>Type test
EN 61131-2
Approvals to EN 61131-2
Other technical data (sheet catalogue) CE, cULus
Measured variables Technical Data
Channels
Rated voltage through supply terminal [UL ] Voltage
Rated current consumption from supply terminal [IL ] 1 Number
Rated current consumption from module bus [IMB ] 24 V DC
Heat dissipation 50 mA
Encoder supply ≦ 41 mA
Input voltage < 1 W
Maximum input voltage Linked to L+ and L- of the supply; not short-circuit protected
Input impedance -10/0 to +10 V DC
Limit frequency (-3 db) 35 V continuous V DC
Offset error ≧ 98.5 kΩ
Linearity 200 Hz
Basic error limit at 23 °C 0.1 %
Repetition accuracy (deviation) 0.03 %
Temperature coefficient 0.2 %
Resolution of the A/D converter 0.05 %
Measuring principle 300 ppm/°C of full scale
Measured value representation 14-bit (signed integer)
Diagnostics Successive approximation
Base modules
>without C connection
16-bit signed integer
12-bit signed integer left-justified
12-bit full range left-justified
Base modules
>without C connection, for sensor feeding
Yes
Measured variables 2-/3-wire
XN-S3x-SBB
Channels 4-wire
XN-S4x-SBBS
Rated voltage through supply terminal [UL ]
Rated current consumption from supply terminal [IL ] Voltage
Rated current consumption from module bus [IMB ] 1 Number
Heat dissipation 24 V DC
Offset error 50 mA
Linearity ≦ 41 mA
Basic error limit at 23 °C < 1 W
Repetition accuracy (deviation) 0.1 %
Temperature coefficient 0.03 %
Measured value representation 0.2 %
Base modules
>without C connection
0.05 %
Channels 300 ppm/°C of full scale
Rated voltage through supply terminal [UL ] 16-bit signed integer
12-bit signed integer left-justified
12-bit full range left-justified
Rated current consumption from the supply terminal (at load current = 0 mA) [IL ] 2-/3-wire
XN-S3x-SBB
Rated current consumption from module bus [IMB ]
Diagnostics 1 Number
Channels 24 V DC
Rated voltage through supply terminal [UL ] 50 mA
Rated current consumption from supply terminal [IL ] ≦ 41 mA
Rated current consumption from module bus [IMB ] Yes
Heat dissipation
Base modules
>without C connection
1 Number
Rated voltage through supply terminal [UL ] 24 V DC
Rated current consumption from supply terminal [IL ] 50 mA
Rated current consumption from module bus [IMB ] ≦ 41 mA
Base modules
>without C connection
< 1 W
Rated voltage through supply terminal [UL ] 2-/3-wire
XN-S3x-SBB
Rated current consumption from supply terminal [IL ]
Rated current consumption from module bus [IMB ] 24 V DC
Channels 50 mA
Rated voltage through supply terminal [UL ] ≦ 41 mA
Rated current consumption from supply terminal [IL ] 2-/3-wire
XN-S3x-SBB
Rated current consumption from module bus [IMB ]
Heat dissipation 24 V DC
Temperature coefficient 50 mA
Number of parameter bits ≦ 41 mA
without C connection, for sensor feeding
Rated voltage through supply terminal [UL ] 1 Number
Rated current consumption from supply terminal [IL ] 24 V DC
Rated current consumption from module bus [IMB ] 50 mA
Number of parameter bytes ≦ 41 mA
Base modules
>without C connection, for sensor feeding
< 1 W
Rated operational current for specified heat dissipation [In]
Heat dissipation per pole, current-dependent [Pvid] 300 ppm/°C of full scale
Equipment heat dissipation, current-dependent [Pvid] 3-bit
Static heat dissipation, non-current-dependent [Pvs]
Heat dissipation capacity [Pdiss] 4-wire
XN-S4x-SBBS
Operating ambient temperature min.
Operating ambient temperature max. 24 V DC
Degree of Protection 50 mA
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
≦ 41 mA
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
3-bit
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
4-wire
XN-S4x-SBBS
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 A
10.2 Strength of materials and parts
>10.2.5 Lifting
0 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
0 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
1 W
10.3 Degree of protection of ASSEMBLIES 0 W
10.4 Clearances and creepage distances 0 °C
10.5 Protection against electric shock +55 °C
10.6 Incorporation of switching devices and components IP20
10.7 Internal electrical circuits and connections
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Meets the product standard´s requirements.
Supply voltage AC 50 Hz Meets the product standard´s requirements.
Supply voltage AC 60 Hz Meets the product standard´s requirements.
Supply voltage DC Does not apply, since the entire switchgear needs to be evaluated.
Voltage type of supply voltage Does not apply, since the entire switchgear needs to be evaluated.
Input, current Is the panel builder´s responsibility.
Input, voltage Is the panel builder´s responsibility.
Input, resistor Is the panel builder´s responsibility.
Input, resistance thermometer Is the panel builder´s responsibility.
Input, thermocouple Is the panel builder´s responsibility.
Input signal, configurable The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Resolution of the analogue inputs Is the panel builder´s responsibility.
Output, current Is the panel builder´s responsibility.
Output, voltage The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Output signal configurable
Resolution of the analogue outputs
Number of analogue inputs 0 - 0 V
Number of analogue outputs 0 - 0 V
Analogue inputs configurable 20.4 - 28.8 V
Analogue outputs configurable DC
Number of HW-interfaces industrial Ethernet No
Number of interfaces PROFINET Yes
Number of HW-interfaces RS-232 No
Number of HW-interfaces RS-422 No
Number of HW-interfaces RS-485 No
Number of HW-interfaces serial TTY Yes
Number of HW-interfaces parallel 16 Bit
Number of HW-interfaces Wireless No
Number of HW-interfaces USB No
Number of HW-interfaces other No
Supporting protocol for TCP/IP 0 Bit
Supporting protocol for PROFIBUS 1
Supporting protocol for CAN 0
Supporting protocol for INTERBUS Yes
Supporting protocol for ASI Yes
Supporting protocol for KNX 0
Supporting protocol for MODBUS 0
Supporting protocol for Data-Highway 0
Supporting protocol for DeviceNet 0
Supporting protocol for SUCONET 0
Supporting protocol for LON 0
Supporting protocol for PROFINET IO 0
Supporting protocol for PROFINET CBA 0
Supporting protocol for SERCOS 0
Supporting protocol for Foundation Fieldbus 1
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Radio standard Bluetooth No
Radio standard WLAN 802.11 No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
IO link master No
System accessory No
Degree of protection (IP) No
Degree of protection (NEMA) No
Type of electric connection No
Fieldbus connection over separate bus coupler possible No
Rail mounting possible No
Wall mounting/direct mounting No
Front build in possible No
Rack-assembly possible No
Suitable for safety functions No
Category according to EN 954-1 No
SIL according to IEC 61508 No
Performance level acc. EN ISO 13849-1 No
Appendant operation agent (Ex ia) No
Appendant operation agent (Ex ib) No
Explosion safety category for gas Yes
Explosion safety category for dust IP20
Width
Height Screw-/spring clamp connection
Depth Yes
Product Standards Yes
UL File No. No
UL Category Control No. No
CSA File No. No
CSA Class No. No
North America Certification
Specially designed for North America None
Current Limiting Circuit-Breaker None
Degree of Protection No
Link to sheet catalogue No