SKU: Eaton-140038
Counter module XI/ON ECO, 24 V DC, 2 channels
The XI/ON standard I/O system adds cost and space-optimized I/O modules and gateways to the XI/ON I/O system. The ECO modules do not need base modules and are fully compatible with the standard XI/ON system. High channel density (up to 16 DI/DO on 13 mm), push-in spring-cage terminals, 8 or 16 channels per module. The ECO gateways support the CANopen bus systems Profibus DP and Ethernet.
Function | XI/ON technology modules |
Function | XN Slice module |
Short Description | 2 counter channels and 2 PWM channels Counting modes: infinite, once only or periodic count Frequency, rotational speed or period count Acquisition of signals from rotary encoders (track A/B) Output of a defined digital signal Output of a defined number of pulses |
Rated operational current for specified heat dissipation [In] | |
Heat dissipation per pole, current-dependent [Pvid] | 0 A |
Equipment heat dissipation, current-dependent [Pvid] | 0 W |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 2 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | 0 °C |
Degree of Protection | +55 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
IP20 |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
|
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.13 Mechanical function | Is the panel builder´s responsibility. |
Supply voltage AC 50 Hz | Is the panel builder´s responsibility. |
Supply voltage AC 60 Hz | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Supply voltage DC | |
Voltage type of supply voltage | |
Number of functions | 0 - 0 V |
Number of HW-interfaces industrial Ethernet | 0 - 0 V |
Number of interfaces PROFINET | 11 - 30 V |
Number of HW-interfaces RS-232 | DC |
Number of HW-interfaces RS-422 | 0 |
Number of HW-interfaces RS-485 | 0 |
Number of HW-interfaces serial TTY | 0 |
Number of HW-interfaces parallel | 0 |
Number of HW-interfaces Wireless | 0 |
Number of HW-interfaces USB | 0 |
Number of HW-interfaces other | 0 |
With optical interface | 0 |
Supporting protocol for TCP/IP | 0 |
Supporting protocol for PROFIBUS | 0 |
Supporting protocol for CAN | 1 |
Supporting protocol for INTERBUS | No |
Supporting protocol for ASI | No |
Supporting protocol for KNX | Yes |
Supporting protocol for MODBUS | Yes |
Supporting protocol for Data-Highway | No |
Supporting protocol for DeviceNet | No |
Supporting protocol for SUCONET | No |
Supporting protocol for LON | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFINET CBA | Yes |
Supporting protocol for SERCOS | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | No |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for other bus systems | No |
Radio standard Bluetooth | No |
Radio standard WLAN 802.11 | No |
Radio standard GPRS | No |
Radio standard GSM | No |
Radio standard UMTS | No |
IO link master | No |
System accessory | No |
Suitable for counting | No |
Suitable for weighting | No |
Suitable for temperature control | No |
Suitable for welding control | Yes |
Suitable for pressure control | Yes |
Suitable for NC | No |
Function electronic positioning available | No |
Suitable for CNC | No |
Suitable for SSI | No |
Suitable for incremental data detection | No |
Suitable for detection absolute value | Yes |
Flux controller possible | No |
Suitable for flux measurement | No |
Suitable for path controller | Yes |
Suitable for cam controller | Yes |
Suitable for flying saw | No |
Suitable for multi-axis control | No |
Single-axis controller possible | No |
Suitable for multi-axis positioning | No |
Single-axis positioning possible | No |
Function block restart blockage | No |
Function block automatic reset | Yes |
Contactor control function block | No |
Function block emergency stop | Yes |
Function block contactless working protection installation | No |
Function block affirm pushbutton | No |
Function block 2-hand switching | No |
Function block operating mode selection | No |
Function block access control | No |
Degree of protection (IP) | No |
Degree of protection (NEMA) | No |
Fieldbus connection over separate bus coupler possible | Yes |
Frequency measurement | No |
Rail mounting possible | IP20 |
Wall mounting/direct mounting | |
Front build in possible | Yes |
Rack-assembly possible | Yes |
Suitable for safety functions | No |
Category according to EN 954-1 | No |
SIL according to IEC 61508 | No |
Performance level acc. EN ISO 13849-1 | No |
Appendant operation agent (Ex ia) | No |
Appendant operation agent (Ex ib) | |
Explosion safety category for gas | None |
Explosion safety category for dust | None |
Width | No |
Height | No |
Depth | None |
Specially designed for North America | None |
Current Limiting Circuit-Breaker | 13 mm |
Degree of Protection | 161.5 mm |
Link to sheet catalogue | 74.5 mm |