116026 SWD4-100LF8-24

Flat cable, SmartWire-DT, 100m, 8-Pole
SmartWire-DT ribbon cable for connecting SmartWire-DT participants within the control panel, 100m, 8-Pole, not assembled

Ürün Açıklaması

Flat cable, SmartWire-DT, 100m, 8-Pole
SmartWire-DT ribbon cable for connecting SmartWire-DT participants within the control panel, 100m, 8-Pole, not assembled
Product range SmartWire-DT accessories
Basic function SWD ribbon cable
Function For connecting the SmartWire-DT modules within the control panel
Description 8 pole
not ready-assembled
Length 100 m
Note regarding length 1 off
Connection to SmartWire-DT yes
For use with EU5C-SWD…
EU5E-SWD…
M22-SWD…
DIL-SWD…
Protection type (IEC/EN 60529, EN50178, VBG 4) IP20
Approvals UL
CSA
Protection type (IEC/EN 60529, EN50178, VBG 4) IP20
Operating ambient temperature (IEC 60068-2)
>Operating ambient temperature max.
+55 °C
Condensation Take appropriate measures to prevent condensation
Relative humidity, non-condensing (IEC/EN 60068-2-30) 5 - 95 %
Operating ambient temperature min. -25 °C
Operating ambient temperature max. +55 °C
Degree of Protection IP20
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Conductor surface Tinned
Diameter conductor 1.35 mm
Nominal cross section conductor 0.23 mm²
AWG-size 24
Conductor category Class 2 = stranded
Number of cores 8
Number of stranding elements 0
Stranding element No
Core insulation material Polyvinyl chloride (PVC)
Specification core insulation Other
Core identification Colour
Screen over stranding element None
Stranding Other
Screen over stranding None
Longitudinal water blocking cable No
Radial water blocking cable No
Protective sheath Other
Armouring No
Material outer sheath Polyvinyl chloride (PVC)
Specification material outer sheath Other
Colour outer sheath Green
Reaction-to-fire class according to EN 13501-6 None
Smoke development class according to EN 13501-6 None
Euro class flaming droplets/particles according to EN 13501-6 None
Euro class acidity according to EN 13501-6 None
Halogen free (acc. EN 60754-1/2) No
Halogen free (acc. IEC 60754-2) No
Flame retardant In accordance with EN 60332-1-2
Low smoke (acc. EN 61034-2) No
Low smoke (acc. IEC 61034-2) No
Oil resistant (acc. EN 60811-404) No
Oil resistant (acc. IEC 60811-404) No
Insulation integrity in accordance with IEC 60331 No
Circuit integrity No
Outer diameter approx. 17.5 mm
Min. permitted bending radius, moving application with forced guidance 15 mm
Min. permitted bending radius, moving application/free movement 15 mm
Min. permitted bending radius, stationary application/permanent installation 7.5 mm
Permitted cable outer temperature during assembling/handling -10 - 105 °C
Permitted cable outer temperature after assembling without vibration -30 - 105 °C
Category Other
NVP value 66.7 %
Underground installation No
UV resistant No
UL File No. E29184
UL Category Control No. NKCR
CSA File No. 2324643
CSA Class No. 3211-07
North America Certification UL listed, CSA certified
Specially designed for North America No