115996 M22-SWD-KC22

Function element, for combination with RMQ-Titan operating elements M22-..., 2 changeover contact, Base fixing
Function element, Fixing: Base fixing, Connection to SmartWire-DT: yes

Ürün Açıklaması

Function element, for combination with RMQ-Titan operating elements M22-..., 2 changeover contact, Base fixing
Function element, Fixing: Base fixing, Connection to SmartWire-DT: yes
Basic function accessories Function elements
Function for combination with RMQ-Titan operating elements M22-...
Contacts 2 changeover contact
Fixing Base fixing
Contact sequence 2723SWI-5
Contact travel diagram
stroke in connection with front element
116U024
Configuration 116Q015
Connection to SmartWire-DT yes
Standards IEC/EN 61131-2
EN 50178
Dimensions (W x H x D) 17 x 45 x 37 mm
Weight 14 g
Mounting position As required
Protection type (IEC/EN 60529, EN50178, VBG 4) IP20
Vibrations (IEC/EN 61131-2:2008)
>Constant amplitude 3,5 mm
5 - 8.4 Hz
Vibrations (IEC/EN 61131-2:2008)
>Constant acceleration 1 g
8.4 - 150 Hz
Mechanical shock resistance (IEC/EN 60068-2-27) semi-sinusoidal 15 g/11 ms 9 Impacts
Drop to IEC/EN 60068-2-31 [Drop height] 50 mm
Free fall, packaged (IEC/EN 60068-2-32) 0.3 m
Overvoltage category Not applicable
Pollution degree 2
Electrostatic discharge (IEC/EN 61131-2:2008)
>Air discharge (Level 3)
8 kV
Electrostatic discharge (IEC/EN 61131-2:2008)
>Contact discharge (Level 2)
4 kV
Electromagnetic fields (IEC/EN 61131-2:2008)
>80 - 1000 MHz
10 V/m
Electromagnetic fields (IEC/EN 61131-2:2008)
>1.4 - 2 GHz
3 V/m
Electromagnetic fields (IEC/EN 61131-2:2008)
>2 - 2.7 GHz
1 V/m
Radio interference suppression (SmartWire-DT) EN 55011 Class A
Burst (IEC/EN 61131-2:2008, Level 3)
>Supply cable
2 kV
Burst (IEC/EN 61131-2:2008, Level 3)
>SmartWire-DT cable
1 kV
Radiated RFI (IEC/EN 61131-2:2008, Level 3) 10 V
Ambient temperature
>Operating ambient temperature (IEC 60068-2)
-30 - +55 °C
Ambient temperature
>Storage
- 40 - + 80 °C
Relative humidity
>Condensation
Take appropriate measures to prevent condensation
Relative humidity
>Relative humidity, non-condensing (IEC/EN 60068-2-30)
5 - 95 %
Station type SmartWire-DT slave
Address allocation automatic
Status indication Green LED
Connections Plug, 8-pole
Plug connectors M22-SWD-I…LP
Baud rate setting automatic
Switching state display No LED
Diagnostics Yes
Fixing Base fixing
Rated operational current for specified heat dissipation [In] 0 A
Heat dissipation per pole, current-dependent [Pvid] 0 W
Equipment heat dissipation, current-dependent [Pvid] 0 W
Static heat dissipation, non-current-dependent [Pvs] 0.3 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. -30 °C
Operating ambient temperature max. +55 °C
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of contacts as change-over contact 0
Number of contacts as normally open contact 2
Number of contacts as normally closed contact 2
Number of fault-signal switches 0
Rated operation current Ie at AC-15, 230 V 0 A
Type of electric connection Flat plug-in connection
Model Top mounting
Mounting method Floor fastening
Lamp holder None
UL File No. E29184
UL Category Control No. NKCR
CSA File No. 2324643
CSA Class No. 3211-07
North America Certification UL listed, CSA certified
Specially designed for North America No