Ürün Açıklaması
Bus-mounted switch-disconnector with fuses, 63A, 400 V, 3p, D02, HK
The flash function indicates the blowing of fuse link, delivery empty, without adapter sleeves and fuse links, retaining springs for D01 fuse links or cylindrical fuse links 10x38 supplied, contact position indicator, fuse plug without screw cap, switches the load on all poles and without touching by hand, version D02-LTS/63/3-R-HK with integrated auxiliary contact, sealable and lockable
Product range |
60 mm system 185 mm system |
Basic function |
Busbar fuse material |
Subrange |
D fuse switch-disconnectors with flashing function |
Description |
The flash function indicates the blowing of fuse link Supplied empty, without adapter sleeves and fuse links Retaining springs for D01 fuse links or cylindrical fuse links 10x38 supplied Contact position indicator Fuse plug without screw cap Switches the load on all poles and without touching by hand with integrated auxiliary contact Sealable and lockable |
Contact sequence |
|
Rated operational current [Ie] |
63 A |
Rated operational voltage [Ue] |
400 V AC |
Frame size |
E18, D02, C10x38 |
Mounting width |
27 mm |
For use with |
12 x 5/10 15 x 5/10 20 x 5/10 25 x 5/10 30 x 5/10 |
For use with |
Double T profile |
Standards |
Version according to IEC/EN 60947-3 |
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Ambient temperature |
-25 - +55 |
Interval between busbar centres |
60 mm |
Mounting position |
Vertical or horizontal |
Overvoltage category/pollution degree |
IV/3 |
Degree of Protection |
IP40 enclosed |
Weight |
0.34 kg |
Rated frequency [f] |
40 - 60 Hz |
Rated impulse withstand voltage [Uimp] |
6 kV |
Interval between busbar centres |
60 mm |
Overvoltage category/pollution degree |
IV/3 |
Number of poles |
3 pole |
Number of poles |
3P |
Rated operational voltage [Ue] >Rated operating voltage [Ue] |
400 V AC |
Rated conditional short-circuit current tested with links [Iq] |
63 kA |
Rated frequency [f] |
40…60 Hz |
Rated operational current [Ie] |
63 A |
Conventional thermal current [Ith
] |
63 A |
Control mode |
Uninterrupted operation |
Overvoltage category |
IV |
Utilization category |
AC 22 B |
Rated impulse withstand voltage [Uimp] |
6 kV |
Current heat loss per contact at Ie |
1.5 W |
Power loss >Heat dissipation per contact with fuse link at Ie
|
7 W |
Power loss >Fuse |
5.5 W |
Frame size |
E18, D02, C10x38 |
Box terminal >Solid |
1.5 - 35 Cu mm2 |
Terminals |
Lift terminals |
Tightening torque of terminal screws |
max. 4 Nm |
Temperature range |
-25 - +55 °C |
Enclosure width |
226 mm |
Mounting width |
27 mm |
Overvoltage category/pollution degree |
IV/3 |
Operating ambient temperature min. |
-25 °C |
Operating ambient temperature max. |
+55 °C |