SKU: Eaton-107579
Molded Case Switch, 3p, 200A
Molded Case Switch, N2, Switch-disconnectors, 3 pole, Switching capacity SCCR 480Y/277 V 60 Hz Icu: 100 kA, S Switching capacity SCCR 600Y/347 V 60 Hz Icu: 50 kA, Rated current = rated uninterrupted current In = Iu: 200 A, Rated current = rated uninterrupted current In = Iu: 200 A, Standard/Approval: UL/CSA, IEC, Installation type: Fixed, Box terminal, Protective function: Disconnectors/main switches
Product range | Switch-disconnectors |
Protective function | Disconnectors/main switches |
Standard/Approval | UL/CSA, IEC |
Installation type | Fixed |
Construction size | N2 |
Description | IEC/EN 60947-2: Circuit-breakers without overcurrent (CBI-X) with main switch characteristics and isolating characteristics to IEC/EN 60204. |
Number of poles | 3 pole |
Standard equipment | Box terminal |
Switch positions | I, +, 0 |
Rated current = rated uninterrupted current [In = Iu] | 200 A |
Rated current = rated uninterrupted current [In = Iu] | 200 A |
SCCR 480Y/277 V 60 Hz [Icu] | 100 kA |
SCCR 480 V 60 Hz [Icu] | 100 kA |
SCCR 600Y/347 V 60 Hz [Icu] | 50 kA |
Non-delayed [Ii = In x …] | 2500 A fixed |
Rated surge voltage invariability [Uimp
] >Main contacts |
8000 V |
Rated surge voltage invariability [Uimp
] >Auxiliary contacts |
6000 V |
Rated operational voltage [Ue] | 690 V AC |
Rated current = rated uninterrupted current [In = Iu] | 200 A |
Rated current = rated uninterrupted current [In = Iu] | 200 A |
Rated uninterrupted current [Iu
] >IEC/EN 61131-3 [Iu ] |
250 A |
Rated uninterrupted current [Iu
] >UL 489, CSA 22.2 No. 5.1 [Iu ] |
250 A |
Overvoltage category/pollution degree | III/3 |
Rated insulation voltage [Ui ] | 1000 V |
Other technical data (sheet catalogue) | Weight Temperature dependency, Derating Effective power loss |
Ambient temperature >Ambient temperature, storage |
- 40 - + 70 °C |
Ambient temperature >Operation |
-25 - +70 °C |
Mounting position | |
Direction of incoming supply | as required |
Degree of protection >Device |
In the area of the HMI devices: IP20 (basic protection type) |
Degree of protection >Enclosures |
With insulating surround: IP40 With door coupling rotary handle: IP66 |
Degree of protection >Terminations |
Tunnel terminal: IP10 Phase isolator and band terminal: IP00 |
SCCR 240 V 60 Hz [Icu] | 150 kA |
SCCR 480Y/277 V 60 Hz [Icu] | 100 kA |
SCCR 480 V 60 Hz [Icu] | 100 kA |
SCCR 600Y/347 V 60 Hz [Icu] | 50 kA |
240 V 50/60 Hz [Icm ] | 330 kA |
400/415 V 50/60 Hz [Icm ] | 330 kA |
440 V 50/60 Hz [Icm ] | 286 kA |
525 V 50/60 Hz [Icm ] | 105 kA |
690 V 50/60 H [Ic] | 53 kA |
Icu to IEC/EN 60947 test cycle O-t-CO [Icu] >240 V 50/60 Hz [Icu ] |
150 kA |
Icu to IEC/EN 60947 test cycle O-t-CO [Icu] >400/415 V 50 Hz [Icu ] |
150 kA |
Icu to IEC/EN 60947 test cycle O-t-CO [Icu] >440 V 50/60 Hz [Icu ] |
130 kA |
Icu to IEC/EN 60947 test cycle O-t-CO [Icu] >525 V 50/60 Hz [Icu ] |
50 kA |
Icu to IEC/EN 60947 test cycle O-t-CO [Icu] >690 V 50/60 Hz [Icu ] |
20 kA |
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] >230 V 50/60 Hz [Ics ] |
150 kA |
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] >400/415 V 50/60 Hz [Ics ] |
150 kA |
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] >440 V 50/60 Hz [Ics ] |
130 kA |
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] >525 V 50/60 Hz [Ics ] |
37.5 kA |
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO [Ics] >690 V 50/60 Hz [Ics] |
5 kA |
Lifespan, mechanical [Operations] | 20000 |
Max. operating frequency | 120 Ops/h |
400 V 50/60 Hz [Operations] | 10000 |
415 V 50/60 Hz [Operations] | 10000 |
690 V 50/60 Hz [Operations] | 7500 |
400 V 50/60 Hz [Operations] | 6500 |
415 V 50/60 Hz [Operations] | 6500 |
690 V 50/60 Hz [Operations] | 5000 |
Standard equipment | < 10 ms |
Optional accessories | Box terminal |
Copper conductors and cables >Box terminal >Solid |
Screw connection Tunnel terminal connection on rear |
Copper conductors and cables >Box terminal >Stranded |
1 x (10 - 16) 2 x (6 - 16) mm2 |
Copper conductors and cables >Tunnel terminal >Solid |
1 x (25 - 185) 2 x (25 - 70) mm2 |
Copper conductors and cables >Tunnel terminal >Stranded >1-hole |
1 x 16 mm2 |
Copper conductors and cables >Bolt terminal and rear-side connection >Direct on the switch >Solid |
1 x (25 - 185) mm2 |
Copper conductors and cables >Bolt terminal and rear-side connection >Direct on the switch >Stranded |
1 x (10 - 16) 2 x (4 - 16) mm2 |
Al conductors, Al cable >Tunnel terminal >Solid |
1 x (25 - 185) 2 x (25 - 70) mm2 |
Al conductors, Al cable >Tunnel terminal >Stranded >1-hole |
1 x 16 mm2 |
Al conductors, Al cable >Bolt terminal and rear-side connection >Direct on the switch >Solid |
1 x (25 - 185) mm2 |
Al conductors, Al cable >Bolt terminal and rear-side connection >Direct on the switch >Stranded |
1 x (10 - 16) 2 x (10 - 16) mm2 |
Cu strip (number of segments x width x segment thickness) >Box terminal [min.] |
1 x (25 - 35) 2 x (25 - 35) mm2 |
Cu strip (number of segments x width x segment thickness) >Box terminal [max.] |
2 x 9 x 0.8 mm |
Cu strip (number of segments x width x segment thickness) >Bolt terminal and rear-side connection >Flat copper strip, with holes [min.] |
10 x 16 x 0.8 (2x) 8 x 15.5 x 0.8 mm |
Cu strip (number of segments x width x segment thickness) >Bolt terminal and rear-side connection >Flat copper strip, with holes [max.] |
2 x 16 x 0.8 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Screw connection |
10 x 24 x 0.8 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [min.] |
M8 |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [max.] |
16 x 5 mm |
Copper conductors and cables >Box terminal >solid |
24 x 8 mm |
Copper conductors and cables >Box terminal >Stranded |
1 x (12 - 6) AWG |
Copper conductors and cables >Tunnel terminal >solid |
1 x (4 - 350) AWG/kcmil |
Copper conductors and cables >Tunnel terminal >Stranded >1-hole |
1 x 6 AWG |
Copper conductors and cables >Bolt terminal and rear-side connection >Direct on the switch >solid |
1 x (4 - 350) AWG/kcmil |
Cu strip (number of segments x width x segment thickness) >Box terminal [min.] |
1 x (12 - 6) AWG |
Cu strip (number of segments x width x segment thickness) >Box terminal [max.] |
2 x 9 x 0.8 mm |
Cu strip (number of segments x width x segment thickness) >Bolt terminal and rear-side connection >Flat copper strip, with holes [min.] |
10 x 16 x 0.8 mm |
Cu strip (number of segments x width x segment thickness) >Bolt terminal and rear-side connection >Flat copper strip, with holes [max.] |
2 x 16 x 0.8 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Screw connection |
10 x 16 x 0.8 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [min.] |
M8 |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [max.] |
16 x 5 mm |
Rated operational current for specified heat dissipation [In] | 20 x 5 mm |
Equipment heat dissipation, current-dependent [Pvid] | 200 A |
Operating ambient temperature min. | 38.04 W |
Operating ambient temperature max. | -25 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
+70 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated permanent current Iu | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Rated voltage | 200 A |
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz | 690 - 690 V |
Overload release current setting | 150 kA |
Adjustment range short-term delayed short-circuit release | 0 - 0 A |
Adjustment range undelayed short-circuit release | 0 - 0 A |
Integrated earth fault protection | 2500 - 2500 A |
Type of electrical connection of main circuit | No |
Device construction | Frame clamp |
Suitable for DIN rail (top hat rail) mounting | Built-in device fixed built-in technique |
DIN rail (top hat rail) mounting optional | No |
Number of auxiliary contacts as normally closed contact | Yes |
Number of auxiliary contacts as normally open contact | 0 |
Number of auxiliary contacts as change-over contact | 0 |
With switched-off indicator | 0 |
With under voltage release | No |
Number of poles | No |
Position of connection for main current circuit | 3 |
Type of control element | Front side |
Complete device with protection unit | Rocker lever |
Motor drive integrated | Yes |
Motor drive optional | No |
Degree of protection (IP) | Yes |
Product Standards | IP20 |
UL File No. | UL 489; CSA-C22.2 No. 5-09; IEC 60947-2; CE marking |
UL Category Control No. | E148671 |
CSA File No. | WJAZ |
CSA Class No. | 022086 |
North America Certification | 4652-06 |
Specially designed for North America | UL listed, CSA certified |
Suitable for | Yes |
Current Limiting Circuit-Breaker | Feeder circuits, branch circuits |
Max. Voltage Rating | No |
Degree of Protection | 600Y/347 V |
Characteristic curve | IEC: IP20; UL/CSA Type: - |
Characteristic curve |