Busbar adapter, 3p, for NZM1, 160A, UL508
Type-checked busbar adapter for NZM circuit-breaker and N switch-disconnector, for surface mounting on Cu-busbars 12-30x5-10, double t and triple t profile, rated operational current Ie=160A, can be used for NZM1, PN1, N(S)1, adapter width=90mm, rated operating voltage Ue=690VAC, combi base for latching onto the busbar 5mm or 10mm thickness, connection top or bottom possible by turning the adapter, temperature resistant to 120 °C, self-extinguishing to UL 94, track resistance CTI 200, number of poles=3 pole, between busbar centers=60mm, can be used in conjunction with busbar system SASY 60i, UL approved, observe derating
Product range | 60 mm system Compact system |
|||||||||||||||||||||||||||||||||||||||||||||
Basic function | Busbar adapters for NZM | |||||||||||||||||||||||||||||||||||||||||||||
Subrange | Component adapter for circuit-breakers and switch-disconnectors | |||||||||||||||||||||||||||||||||||||||||||||
Function | For surface mounting on flat copper busbars 12 – 30 x 5 – 10, double T and triple T profile | |||||||||||||||||||||||||||||||||||||||||||||
Rated operational voltage [Ue] | 690 V AC | |||||||||||||||||||||||||||||||||||||||||||||
Temperature resistant | to 120°C | |||||||||||||||||||||||||||||||||||||||||||||
Rated diversity factor |
|
|||||||||||||||||||||||||||||||||||||||||||||
Self-extinguishing | to UL 94 | |||||||||||||||||||||||||||||||||||||||||||||
Track resistance | CTI 200 | |||||||||||||||||||||||||||||||||||||||||||||
Number of poles | 3 pole | |||||||||||||||||||||||||||||||||||||||||||||
Rated operational current [Ie] | 160 A | |||||||||||||||||||||||||||||||||||||||||||||
Adapter width | 92 mm | |||||||||||||||||||||||||||||||||||||||||||||
For use with | NZM1, PN1, N(S)1 |
|||||||||||||||||||||||||||||||||||||||||||||
Cu factor | 0,25 kg | |||||||||||||||||||||||||||||||||||||||||||||
Notes | For switch and standard connection with box terminal. Integrated adapters allow connection to system on top or bottom. Increased protection against direct contact on the switch output side is possible in conjunction with IP2X protection against contact with a finger. Latch fitting to busbar using combination stand Can be adjusted to 5-mm and 10-mm rail thicknesses and back thanks to the integrated combination stand. Rated short-circuit switching capacity 35 kA at 480 V. Mounted by latching onto de-energized busbar. |
|||||||||||||||||||||||||||||||||||||||||||||
Product Standards | UL508A; CSA-C22.2 No. 14; IEC 61439-1; CE marking | |||||||||||||||||||||||||||||||||||||||||||||
UL File No. | E140305 | |||||||||||||||||||||||||||||||||||||||||||||
UL Category Control No. | DIHS, DIHS7 | |||||||||||||||||||||||||||||||||||||||||||||
CSA File No. | 236217 | |||||||||||||||||||||||||||||||||||||||||||||
CSA Class No. | 3211-37 | |||||||||||||||||||||||||||||||||||||||||||||
North America Certification | UL listed, CSA certified | |||||||||||||||||||||||||||||||||||||||||||||
Conditions of Acceptability | Refer to approbation report | |||||||||||||||||||||||||||||||||||||||||||||
Specially designed for North America | No | |||||||||||||||||||||||||||||||||||||||||||||
Suitable for | Feeder circuits | |||||||||||||||||||||||||||||||||||||||||||||
Current Limiting Circuit-Breaker | Refer to approbation report | |||||||||||||||||||||||||||||||||||||||||||||
Max. Voltage Rating | 600 V AC | |||||||||||||||||||||||||||||||||||||||||||||