102991 MSC-R-12-M12(230V50HZ)/BBA

Reversing starter, 380 V 400 V 415 V: 5.5 kW, Ir= 8 - 12 A, 230 V 50 Hz, 240 V 60 Hz, AC voltage
Reversing starter, Basic device: MSC, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Motor ratings Motor rating AC-3 380 V 400 V 415 V: P= 5.5 kW, Setting range of overload releases: Ir= 8 - 12 A, Coordination: Type of coordination “1”, Actuating voltage: 230 V 50 Hz, 240 V 60 Hz, AC voltage, Standards: UL 508 (on request), CSA C 22.2 No. 14 (on request)

Ürün Açıklaması

Reversing starter, 380 V 400 V 415 V: 5.5 kW, Ir= 8 - 12 A, 230 V 50 Hz, 240 V 60 Hz, AC voltage
Reversing starter, Basic device: MSC, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Motor ratings Motor rating AC-3 380 V 400 V 415 V: P= 5.5 kW, Setting range of overload releases: Ir= 8 - 12 A, Coordination: Type of coordination “1”, Actuating voltage: 230 V 50 Hz, 240 V 60 Hz, AC voltage, Standards: UL 508 (on request), CSA C 22.2 No. 14 (on request)
Basic function Reversing starters (complete devices)
Basic device MSC
Notes 0000SPC-571
Connection to SmartWire-DT Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Motor rating [P]
>AC-3
>380 V 400 V 415 V [P]
no
Rated operational current
>AC-3
>380 V 400 V 415 V [Ie]
5.5 kW
Rated short-circuit current 380 - 415 V [Iq ] 11.3 A
Setting range of overload releases [Ir] 100 kA
Coordination 8 - 12 A
Contact sequence Type of coordination “1”
Actuating voltage 121S030
Motor-protective circuit-breakers 230 V 50 Hz, 240 V 60 Hz
Contactor AC voltage
DOL starter wiring set

Mechanical connection element and electrical electric contact module
PKZM0-12 Type
Notes DILM12-01(…) Part no.
Standards PKZM0-XRM12 Type
Rated impulse withstand voltage [Uimp]

The reversing starter (complete units) consists of a PKZM0 motor protective circuit breaker and two DILM contactors.

These combinations are mounted on the busbar adapters.

The connection of the main circuit between the motor protective circuit breaker and the contactor is established with an electrical contact module.

Complete units with mechanical interlock, starters up to 12 A also feature electrical interlock.

Further informationPage
Technical data PKZM0→ PKZM0
Accessories PKZ→ 072896
Technical data DILM→ DILM
Accessories DIL→ 281199
Overvoltage category/pollution degree
UL 508 (on request)
CSA C 22.2 No. 14 (on request)
Rated operational voltage [Ue] 6000 V AC
Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
III/3
Motor protective circuit breaker PKZM0, PKE 230 - 415 V
DILM contactors
>Power consumption of the coil in a cold state and 1.0 x US
>Dual-voltage coil 50 Hz [Sealing]
12 A
Auxiliary contacts
>Pilot Duty
>AC operated
PKZM0 motor-protective circuit-breakers, see motor-protective circuit-breakers/PKZM0 product group
DILM contactors, see contactor product group
DILET timing relay, ETR, see contactors, electronic timing relays product group
Auxiliary contacts
>Pilot Duty
>DC operated
1.2 W
Auxiliary contacts
>General Use
>AC
A600
Auxiliary contacts
>General Use
>AC
P300
Auxiliary contacts
>General Use
>DC
600 V
Auxiliary contacts
>General Use
>DC
15 A
Rated operational current for specified heat dissipation [In] 250 V
Heat dissipation per pole, current-dependent [Pvid] 1 A
Equipment heat dissipation, current-dependent [Pvid] 12 A
Static heat dissipation, non-current-dependent [Pvs] 3.1 W
Heat dissipation capacity [Pdiss] 9.3 W
Operating ambient temperature min. 1.4 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+55 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Kind of motor starter Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
With short-circuit release The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated control supply voltage Us at AC 50HZ Reversing starter
Rated control supply voltage Us at AC 60HZ Yes
Rated control supply voltage Us at DC 230 - 230 V
Voltage type for actuating 0 - 0 V
Rated operation power at AC-3, 230 V, 3-phase 0 - 0 V
Rated operation power at AC-3, 400 V AC
Rated power, 460 V, 60 Hz, 3-phase 3 kW
Rated power, 575 V, 60 Hz, 3-phase 5.5 kW
Rated operation current Ie 0 kW
Rated operation current at AC-3, 400 V 0 kW
Overload release current setting 11.3 A
Rated conditional short-circuit current, type 1, 480 Y/277 V 12 A
Rated conditional short-circuit current, type 1, 600 Y/347 V 8 - 12 A
Rated conditional short-circuit current, type 2, 230 V 0 A
Rated conditional short-circuit current, type 2, 400 V 0 A
Number of auxiliary contacts as normally open contact 0 A
Number of auxiliary contacts as normally closed contact 0 A
Ambient temperature, upper operating limit 0
Temperature compensated overload protection 0
Release class 60 °C
Type of electrical connection of main circuit Yes
Type of electrical connection for auxiliary- and control current circuit CLASS 10
Rail mounting possible Screw connection
With transformer Screw connection
Number of command positions Yes
Suitable for emergency stop No
Coordination class according to IEC 60947-4-3 0
Number of indicator lights No
External reset possible Class 1
With fuse 0
Degree of protection (IP) No
Degree of protection (NEMA) No
Supporting protocol for TCP/IP IP20
Supporting protocol for PROFIBUS Other
Supporting protocol for CAN No
Supporting protocol for INTERBUS No
Supporting protocol for ASI No
Supporting protocol for MODBUS No
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for LON No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFINET CBA No
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Width No
Height No
Depth 90 mm
Product Standards 200 mm
UL File No. 154 mm
UL Category Control No. UL60947-4-1A; CSA-C22.2 No. 14-10; IEC60947-4-1; CE marking
CSA File No. E123500
CSA Class No. NKJH
North America Certification 12528
Specially designed for North America 3211-04