For star-delta applications Cannot be combined with top mounting auxiliary contacts Incl. suppressor circuits |
US |
100 - 130 V AC 50/60 Hz |
Time range |
Changeover time 1 - 30 s Changeover delay 50 ms |
For use with |
DILM7 - DILM38 DILMP20 DILMP32-DILMP45 DILA DILMF7 DILMF11 DILMF14 DILMF25 DILMF32 |
Contact sequence |
|
Standards |
|
Lifespan, mechanical >AC operated [Operations] |
DIN EN 61812, IEC/EN 60947, VDE 0660, UL, CSA |
Lifespan, mechanical >DC operated [Operations] |
3 x 106
|
Climatic proofing |
3 x 106
|
Ambient temperature >Open |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Ambient temperature >Enclosed |
-25 - +60 °C |
Ambient temperature >Storage |
- 25 - 40 °C |
Mounting position |
- 40 - 80 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >N/O contact |
As required, except suspended |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >N/C contact |
6 g |
Degree of Protection |
6 g |
Protection against direct contact when actuated from front (EN 50274) |
IP20 |
Weight |
Finger and back-of-hand proof |
Terminal capacities >Solid |
0.08 kg |
Terminal capacities >Flexible with ferrule |
1 x (0.75 - 2.5) 2 x (0.75 - 1.5) mm2 |
Terminal capacities >Solid or stranded |
1 x (0.75 - 1.5) 2 x (0.75 - 1.5) mm2 |
Terminal screw |
18 - 14 AWG |
Pozidriv screwdriver |
M3.5 |
Standard screwdriver |
2 Size |
Max. tightening torque |
0.8 x 5.5 1 x 6 mm |
Rated impulse withstand voltage [Uimp] |
1.2 Nm |
Overvoltage category/pollution degree |
|
Rated insulation voltage [Ui] |
4000 V AC |
Rated operational voltage [Ue
] |
III/3 |
Rated operational current [Ie
] >AC-15 >220 V 230 V 240 V [Ie] |
250 V AC |
Rated operational current [Ie
] >DC-13 >DC-13 L/R - 15 ms >Contacts in series: >1 [24 V] |
250 V |
Rated operational current [Ie
] >DC-13 >DC-13 L/R - 15 ms >Contacts in series: >1 [60 V] |
3 A |
Rated operational current [Ie
] >DC-13 >DC-13 L/R - 15 ms >Contacts in series: >1 [110 V] |
1 A |
Rated operational current [Ie
] >DC-13 >DC-13 L/R - 15 ms >Contacts in series: >1 [220 V] |
0.2 A |
Rated operational current [Ie
] >DC-13 >DC L/R ≦ 50 ms >Contacts in series: >1 [24 V] |
0.2 A |
Rated operational current [Ie
] >DC-13 >DC L/R ≦ 50 ms >Contacts in series: >1 [60 V] |
0.1 A |
Rated operational current [Ie
] >DC-13 >DC L/R ≦ 50 ms >Contacts in series: >1 [110 V] |
1 A |
Rated operational current [Ie
] >DC-13 >DC L/R ≦ 50 ms >Contacts in series: >1 [220 V] |
0.2 A |
Rated operational current [Ie
] >DC-13 >DC-13 L/R - 300 ms >Contacts in series: >1 [24 V] |
0.2 A |
Rated operational current [Ie
] >DC-13 >DC-13 L/R - 300 ms >Contacts in series: >1 [60 V] |
0.1 A |
Rated operational current [Ie
] >DC-13 >DC-13 L/R - 300 ms >Contacts in series: >1 [110 V] |
1 A |
Rated operational current [Ie
] >DC-13 >DC-13 L/R - 300 ms >Contacts in series: >1 [220 V] |
0.2 A |
Safe isolation to EN 61140 >between coil and auxiliary contacts |
0.2 A |
Safe isolation to EN 61140 >between the auxiliary contacts |
0.1 A |
Conventional thermal current [Ith
] |
250 V AC |
Short-circuit rating without welding >max. fuse |
250 V AC |
Voltage tolerance >Pick-up voltage >AC operated [Pick-up]0.85 - 1.1 x Uc
Voltage tolerance >Pick-up voltage >DC operated [Pick-up] [Pick-up] 0.7 - 1.2 x Uc
Power consumption >60 °C [Sealing] |
4 A |
Power consumption >AC operated [Sealing] |
4 A gG/gL |
duty factor |
|
Maximum operating frequency >Max. operating frequency |
0.85 - 1.1 x Uc
|
Maximum operating frequency >Can be combined with auxiliary contact |
0.7 - 1.2 x Uc
|
Conventional thermal current Ith = Ie AC-1 >On-delayed |
2 VA |
Conventional thermal current Ith = Ie AC-1 >Off-delayed |
1.8 W |
AC operated 50 Hz [Deviation] |
100 % DF |
Recovery time (after 100% time delay) |
3600 Ops/h |
contact changeover time >DILM32-XTEE11/DILM32-XTED11 [tu] |
360 Ops./h |
contact changeover time >DILM32-XTEY20 [tu] |
< 50 ms |
Notes |
< 200 ms |
Auxiliary contacts >Pilot Duty >AC operated |
< 5 % |
Auxiliary contacts >Pilot Duty >DC operated |
70 ms |
Auxiliary contacts >General Use >AC |
10 ms |
Auxiliary contacts >General Use >AC |
50 ms |
Auxiliary contacts >General Use >DC |
|
Auxiliary contacts >General Use >DC |
For rated operational current: Making and breaking conditions to DC-13, L/R constant as stated Max. fuses for short-circuit protection: Transparent overlay "Fuses" for time/current characteristics (please enquire) For pick-up voltage, DC operated:Pure DC, AC bridge rectifier or smoothed double-wave rectification. |
Short Circuit Current Rating >Basic Rating >SCCR |
|
Short Circuit Current Rating >Basic Rating >max. Fuse |
B300 |
Short Circuit Current Rating >Basic Rating >max. CB |
R300 |
Short Circuit Current Rating >480 V High Fault >SCCR (fuse) |
240 V |
Short Circuit Current Rating >480 V High Fault >max. Fuse |
5 A |
Short Circuit Current Rating >480 V High Fault >SCCR (CB) |
24 V |
Short Circuit Current Rating >480 V High Fault >max. CB |
5 A |
Short Circuit Current Rating >600 V High Fault >SCCR (fuse) |
5 kA |
Short Circuit Current Rating >600 V High Fault >max. Fuse |
125 A |
Short Circuit Current Rating >600 V High Fault >SCCR (CB) |
125 A |
Short Circuit Current Rating >600 V High Fault >max. CB |
10/100 kA |
Rated operational current for specified heat dissipation [In] |
125/70 Class J A |
Heat dissipation per pole, current-dependent [Pvid] |
10/65 kA |
Equipment heat dissipation, current-dependent [Pvid] |
50/32 A |
Static heat dissipation, non-current-dependent [Pvs] |
10/100 kA |
Heat dissipation capacity [Pdiss] |
125/125 Class J A |
Operating ambient temperature min. |
10/22 kA |
Operating ambient temperature max. |
50/32 A |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
|
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 A |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
0 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
1.8 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
0 W |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
-25 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
+60 °C |
10.3 Degree of protection of ASSEMBLIES |
|
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise |
Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating |
Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function |
Does not apply, since the entire switchgear needs to be evaluated. |
Switching function |
Is the panel builder´s responsibility. |
Setting time |
Is the panel builder´s responsibility. |
Number of contacts as normally open contact |
Is the panel builder´s responsibility. |
Number of contacts as normally closed contact |
Is the panel builder´s responsibility. |
Number of contacts as change-over contact |
Is the panel builder´s responsibility. |
Operating principle |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Product Standards |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
UL File No. |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
UL Category Control No. |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
CSA File No. |
|
CSA Class No. |
|
North America Certification |
Other |