SKU: Eaton-72907
Insulated enclosure, E-PKZ0, H x W x D = 129 x 85 x 124 mm, flush-mounted, rotary handle, black/gray, IP55
Insulated enclosure for flush mounting, for PKZM0, degree of protection IP55 integrated terminal for PE(N) connection., Per 2 M25 knockout cable entries, with black-grey rotary knob
Product range | Accessories |
Subrange | Installation enclosures |
Accessories | Insulated enclosures for PKZ |
Degree of Protection | with black-grey rotary knob |
For use with | Front IP55 |
Notes | PKZM0-… +NHI or U or A +NHI-E +L-PKZ0 (2 off) |
Rated operational current for specified heat dissipation [In] | With integrated PE(N) terminal. |
Heat dissipation per pole, current-dependent [Pvid] | |
Equipment heat dissipation, current-dependent [Pvid] | 0 A |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 0 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | 0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
-25 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
+40 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
|
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Please enquire |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Material housing | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Width | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Height | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Depth | |
With transparent cover | |
Suitable for emergency stop | Plastic |
Model | 85 mm |
Degree of protection (IP) | 129 mm |
Degree of protection (NEMA) | 80 mm |
Product Standards | No |
UL File No. | No |
UL Category Control No. | Built-in |
CSA File No. | IP55 |
CSA Class No. | Other |
North America Certification | UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking |
Specially designed for North America | E36332 |
Degree of Protection | NLRV |