SKU: Eaton-046851
Key-operated actuator, 2 positions, white, momentary
Key-operated actuator, Product range: RMQ16, Single unit, Design: Key operated, momentary, 2 positions, Degree of Protection: IP65, without bezel, Connection to SmartWire-DT: no, Front dimensions: Front dimensions 25 × 25 mm, With 1 key, For each color there is a corresponding key, → accessories,, Degree of Protection: IP65
Product range | RMQ16 |
Basic function | Key-operated buttons |
Single unit/Complete unit | Single unit |
Design | Key operated |
Degree of Protection | momentary |
Front ring | 45° |
Connection to SmartWire-DT | 2 positions |
Front dimensions | 0 |
Information about equipment supplied | IP65 |
Ordering information | without bezel |
Notes | no |
Standards | Front dimensions 25 × 25 mm |
Lifespan, mechanical [Operations] | With 1 key |
Operating frequency [Operations/h] | For each color there is a corresponding key, → accessories, |
Operating torque | Additional individual lock mechanisms (each colour corresponds with a separate lock mechanism) |
Degree of protection, IEC/EN 60529 | IEC/EN 60947 |
Climatic proofing | > 3 x 106 |
Ambient temperature >Open |
≦ 1800 |
Ambient temperature >Enclosed |
≦ 0.4 Nm |
Mounting position | IP65 |
Mechanical shock resistance | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Terminal capacities | -25 - +60 °C |
Blade terminal | - 25 - 40 °C |
Fast-on connectors | As required |
Rated impulse withstand voltage [Uimp] | > 40 according to IEC 60068-2-27 Shock duration 11 ms Sinusoidal g |
Rated insulation voltage [Ui ] | 0.5 - 1.0 mm2 |
Overvoltage category/pollution degree | 2.8 x 0.8 mm to DIN 46244 |
Rated operational voltage [Ue] | 2.8 x 0.8 mm to DIN 46247 and IEC 60760 |
Control circuit reliability >at 24 V DC/5 mA [HF ] |
800 V AC |
Control circuit reliability >at 5 V DC/1 mA [HF ] |
250 V |
Use of insulated ferrule ISH 2,8 | III/3 |
Rated operational current for specified heat dissipation [In] | 24 V AC |
Heat dissipation per pole, current-dependent [Pvid] | < 10-7, < 1 failure in 107 operations Fault probability |
Equipment heat dissipation, current-dependent [Pvid] | < 5 x 10-6, < 1 failure in 5 x 106 operations Fault probability |
Static heat dissipation, non-current-dependent [Pvs] | On >24 V AC/DC recommended On >50 V AC or 120 V DC mandatory, also on unoccupied blade terminals |
Heat dissipation capacity [Pdiss] | 0 A |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | 0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
-25 °C |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
+60 °C |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Please enquire |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | Is the panel builder´s responsibility. |
Number of switch positions | Not applicable. |
Type of control element | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Suitable for illumination | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Colour control element | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Colour indicator light cap | 2 |
Construction type lens | Key |
Hole diameter | No |
Width opening | White |
Height opening | Other |
Switching function latching | Square |
Spring-return | 16 mm |
With front ring | 0 mm |
Material front ring | 0 mm |
Colour front ring | No |
Degree of protection (IP), front side | Yes |
Degree of protection (NEMA) | Yes |
Product Standards | Plastic |
UL File No. | Black |
UL Category Control No. | IP65 |
CSA File No. | 1 |
CSA Class No. | IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CE marking |
North America Certification | E29184 |
Degree of Protection | NKCR |