022643 ZG/I48-200

Meter enclosure, HxWxD=750x375x225mm, IP65
Meter enclosure with meter rail, material characteristic polycarbonate, impact-resistant, patented cover fasteners with integrated overpressure compensation, depth=225mm, top and bottom with full area knockouts for FL4... flange, fixing straps for wall fixing, sealable fasteners at the top edge of the cover, meter rail to DIN 43853 including meter fixing screws and nuts, degree of protection IP65, cover type: transparent smoky

Ürün Açıklaması

Meter enclosure, HxWxD=750x375x225mm, IP65
Meter enclosure with meter rail, material characteristic polycarbonate, impact-resistant, patented cover fasteners with integrated overpressure compensation, depth=225mm, top and bottom with full area knockouts for FL4... flange, fixing straps for wall fixing, sealable fasteners at the top edge of the cover, meter rail to DIN 43853 including meter fixing screws and nuts, degree of protection IP65, cover type: transparent smoky
Product range Ci insulated enclosures
Basic function Prepared enclosures
Product function Meter enclosures
Accessories Meter enclosures
Meter rail
Single unit/Complete unit Complete housing
Degree of Protection IP65
Description Top and bottom with full area knockouts for FL-4... flange
No knockouts in the sides
Fixing straps for wall fixing
Sealable cover fasteners
Information about equipment supplied Meter rail to DIN 43853 including meter fixing screws and nuts
Type cover Transparent
Width 375 mm
Height 750 mm
Depth 225 mm
Mounting depth: 186 mm
Legend for the graphic
Enclosure depth Dimensions from top:
Meter rail mounting depth
Enclosure depth
Notes 460N107
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure, free-standing [PV]
Transparent: fitted at top and bottom
with full area knockouts for FL-4... flange
no knockouts in the sides
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure, free-standing [PV]
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure, free-standing [PV]
53 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV]
50 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV]
46 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV]
47 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure, free-standing [PV]
44 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure, free-standing [PV]
40 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure, free-standing [PV]
107 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV]
100 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV]
93 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV]
95 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
88 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
81 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Lower part: 960 °C / cover: 850 °C; meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Not relevant to indoor installations.
10.3 Degree of protection of ASSEMBLIES 40 kg per enclosure with support frame and lifting aid met, assembled and secured as per the latest applicable instruction leaflet.
10.4 Clearances and creepage distances IK10
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components IP65
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Protection class 2, therefore not applicable.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Ui = 1000 V AC
10.11 Short-circuit rating 8 kV
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Mounting method Is the panel builder´s responsibility.
Type of cover Is the panel builder´s responsibility.
Cover model Meets the product standard´s requirements.
Type of door
Transparent cover/door
With lock Surface mounted (plaster)
Nominal current (In) Optional
Height Closed
Width None
Depth Yes
Built-in depth No
Internal depth 1600 A
Plate thickness cabinet 750 mm
Plate thickness door/cover 375 mm
Colour 225 mm
RAL-number 200 mm
Number of modules 200 mm
Number of rows 6 mm
Width in number of modular spacings 6 mm
Number of openings for flange plates Grey
Extension possible 7035
Number of conduit inlets 1
Material housing 0
Surface protection 17
With mounting plate 6
Suitable for outdoor use Yes
Suitable for lightning protection 0
Degree of protection (IP) Plastic
Degree of protection (NEMA) Other
Protection class Yes
Impact strength Yes
Circuit integrity Yes