000797 T3-5-15876/EZ

Reversing star-delta switches, T3, 32 A, centre mounting, 5 contact unit(s), Contacts: 10, 60 °, maintained, With 0 (Off) position, D-Y-0-Y-D, Design number 15876
Turnaround star-delta switch, Product range: Control switches, Part group reference: T3, with black thumb grip and front plate, Contacts: 10, Degree of Protection: Front IP65, Design: centre mounting, Switching angle: 60 °, Switching performance: maintained, With 0 (Off) position, front plate: D-Y-0-Y-D, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 15 kW, Rated uninterrupted current: Iu = 32 A, 5 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3

Ürün Açıklaması

Reversing star-delta switches, T3, 32 A, centre mounting, 5 contact unit(s), Contacts: 10, 60 °, maintained, With 0 (Off) position, D-Y-0-Y-D, Design number 15876
Turnaround star-delta switch, Product range: Control switches, Part group reference: T3, with black thumb grip and front plate, Contacts: 10, Degree of Protection: Front IP65, Design: centre mounting, Switching angle: 60 °, Switching performance: maintained, With 0 (Off) position, front plate: D-Y-0-Y-D, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 15 kW, Rated uninterrupted current: Iu = 32 A, 5 contact unit(s), Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL, Switch-disconnector according to IEC/EN 60947-3
Product range Control switches
Part group reference T3
Basic function Reversing star-delta switches
Contacts with black thumb grip and front plate
Degree of Protection 10
Design Front IP65
Contact sequence centre mounting
Switching angle 000Z081
Switching performance 115S348-2
Design number 60 °
Front plate no. maintained
With 0 (Off) position
front plate 15876
400 V [P] 115K011
Rated uninterrupted current [Iu] D-Y-0-Y-D
Note on rated uninterrupted current !u 15 kW
Number of contact units 32 A
Standards Rated uninterrupted current Iu is specified for max. cross-section.
Climatic proofing 5 contact unit(s)
Ambient temperature
>Open
IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL
Switch-disconnector according to IEC/EN 60947-3
Ambient temperature
>Enclosed
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Overvoltage category/pollution degree -25 - +50 °C
Rated impulse withstand voltage [Uimp] -25 - +40 °C
Mechanical shock resistance III/3
Mounting position 6000 V AC
Electrical characteristics
>Rated operational voltage [Ue]
15 g
Electrical characteristics
>Rated uninterrupted current [Iu]
As required
Electrical characteristics
>Note on rated uninterrupted current !u
690 V AC
Load rating with intermittent operation, class 12
>AB 25 % DF
32 A
Load rating with intermittent operation, class 12
>AB 40 % DF
Rated uninterrupted current Iu is specified for max. cross-section.
Load rating with intermittent operation, class 12
>AB 60 % DF
2 x Ie
Short-circuit rating
>Fuse
1.6 x Ie
Rated short-time withstand current (1 s current) [Icw ] 1.3 x Ie
Note on rated short-time withstand current lcw 35 A gG/gL
Rated conditional short-circuit current [Iq] 650 Arms
cos ϕ rated making capacity as per IEC 60947-3 Current for a time of 1 second
Rated breaking capacity cos ϕ to IEC 60947-3
>230 V
1 kA
Rated breaking capacity cos ϕ to IEC 60947-3
>400/415 V
320 A
Rated breaking capacity cos ϕ to IEC 60947-3
>500 V
260 A
Rated breaking capacity cos ϕ to IEC 60947-3
>690 V
260 A
Safe isolation to EN 61140
>between the contacts
240 A
Safe isolation to EN 61140
>Current heat loss per contact at Ie
170 A
Safe isolation to EN 61140
>Current heat loss per auxiliary circuit at Ie (AC-15/230 V)
440 V AC
Lifespan, mechanical [Operations] 1.1 W
Maximum operating frequency [Operations/h] 1.1 CO
AC
>AC-3
>Rating, motor load switch [P]
>220 V 230 V [P]
> 0.5 x 106
AC
>AC-3
>Rating, motor load switch [P]
>230 V Star-delta [P]
1200
AC
>AC-3
>Rating, motor load switch [P]
>400 V 415 V [P]
5.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>400 V Star-delta [P]
7.5 kW
AC
>AC-3
>Rating, motor load switch [P]
>500 V [P]
11 kW
AC
>AC-3
>Rating, motor load switch [P]
>500 V Star-delta [P]
15 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V [P]
15 kW
AC
>AC-3
>Rating, motor load switch [P]
>690 V Star-delta [P]
18.5 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V [Ie]
11 kW
AC
>AC-3
>Rated operational current motor load switch
>230 V star-delta [Ie]
22 kW
AC
>AC-3
>Rated operational current motor load switch
>400V 415 V [Ie]
23.7 A
AC
>AC-3
>Rated operational current motor load switch
>400 V star-delta [Ie]
32 A
AC
>AC-3
>Rated operational current motor load switch
>500 V [Ie ]
23.7 A
AC
>AC-3
>Rated operational current motor load switch
>500 V star-delta [Ie ]
32 A
AC
>AC-3
>Rated operational current motor load switch
>690 V [Ie]
23.7 A
AC
>AC-3
>Rated operational current motor load switch
>690 V star-delta [Ie]
32 A
AC
>AC-21A
>Rated operational current switch
>440 V [Ie]
14.7 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>230 V [P]
25.5 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>400 V 415 V [P]
32 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>500 V [P]
7.5 kW
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>690 V [P]
15 kW
AC
>AC-23A
>Rated operational current motor load switch
>230 V [Ie]
15 kW
AC
>AC-23A
>Rated operational current motor load switch
>400 V 415 V [Ie]
15 kW
AC
>AC-23A
>Rated operational current motor load switch
>500 V [Ie]
32 A
AC
>AC-23A
>Rated operational current motor load switch
>690 V [Ie]
32 A
DC
>DC-1, Load-break switches L/R = 1 ms
>Rated operational current [Ie]
26.4 A
DC
>DC-1, Load-break switches L/R = 1 ms
>Voltage per contact pair in series
17 A
DC
>DC-21A [Ie ]
>Rated operational current [Ie]
25 A
DC
>DC-21A [Ie ]
>Contacts
60 V
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Rated operational current [Ie]
1 A
DC
>DC-23A, motor load switch L/R = 15 ms
>24 V
>Contacts
1 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Rated operational current [Ie]
25 A
DC
>DC-23A, motor load switch L/R = 15 ms
>48 V
>Contacts
1 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Rated operational current [Ie]
25 A
DC
>DC-23A, motor load switch L/R = 15 ms
>60 V
>Contacts
2 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Rated operational current [Ie]
25 A
DC
>DC-23A, motor load switch L/R = 15 ms
>120 V
>Contacts
3 Quantity
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Rated operational current [Ie]
12 A
DC
>DC-23A, motor load switch L/R = 15 ms
>240 V
>Contacts
3 Quantity
DC
>DC-13, Control switches L/R = 50 ms
>Rated operational current [Ie]
5 A
DC
>DC-13, Control switches L/R = 50 ms
>Voltage per contact pair in series
5 Quantity
Control circuit reliability at 24 V DC, 10 mA [Fault probability] 20 A
Solid or stranded 24 V
Flexible with ferrules to DIN 46228 < 10 -5, < 1 fault in 100000 operations HF
Terminal screw 1 x (1 - 6)
2 x (1 - 6) mm2
Tightening torque for terminal screw 1 x (0.75 - 4)
2 x (0.75 - 4) mm2
Notes M4
Contacts
>Rated operational voltage [Ue]
1.6 Nm
Contacts
>Rated uninterrupted current max.
>Main conducting paths
>General use
B10d values as per EN ISO 13849-1, table C1
Contacts
>Rated uninterrupted current max.
>Auxiliary contacts
>General Use [IU]
600 V AC
Contacts
>Rated uninterrupted current max.
>Auxiliary contacts
>Pilot Duty
25 A
Switching capacity
>Maximum motor rating
>Single-phase
>120 V AC
10 A
Switching capacity
>Maximum motor rating
>Single-phase
>200 V AC
A 600
P 600
Switching capacity
>Maximum motor rating
>Single-phase
>240 V AC
1.5 HP
Switching capacity
>Maximum motor rating
>Three-phase
>200 V AC
3 HP
Switching capacity
>Maximum motor rating
>Three-phase
>240 V AC
3 HP
Switching capacity
>Maximum motor rating
>Three-phase
>480 V AC
3 HP
Switching capacity
>Maximum motor rating
>Three-phase
>600 V AC
3 HP
Short Circuit Current Rating
>Basic Rating
7.5 HP
Short Circuit Current Rating
>max. Fuse
10 HP
Short Circuit Current Rating
>High fault rating
5 kA
Short Circuit Current Rating
>max. Fuse
40 A
Terminal capacity
>Solid or flexible conductor with ferrule
10 kA
Terminal capacity
>Terminal screw
40, Class J A
Terminal capacity
>Tightening torque
14 - 10 AWG
Rated operational current for specified heat dissipation [In] M4
Heat dissipation per pole, current-dependent [Pvid] 17.7 lb-in
Equipment heat dissipation, current-dependent [Pvid] 32 A
Static heat dissipation, non-current-dependent [Pvs] 1.1 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+50 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
UV resistance only in connection with protective shield.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Model Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of poles The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
With 0 (off) position Turnaround star-delta switch
With retraction in 0-position 3
Rated permanent current Iu Yes
Rated operation current Ie at AC-3, 400 V No
Rated operation power at AC-3, 400 V 32 A
Degree of protection (IP), front side 23.7 A
Degree of protection (NEMA), front side 18.5 kW
Number of auxiliary contacts as normally closed contact IP65
Number of auxiliary contacts as normally open contact 12
Number of auxiliary contacts as change-over contact 0
Suitable for ground mounting 0
Suitable for front mounting 4-hole 0
Suitable for distribution board installation No
Suitable for intermediate mounting Yes
Complete device in housing No
Material housing No
Type of control element No
Type of electrical connection of main circuit Plastic
Product Standards Toggle
UL File No. Screw connection
UL Category Control No. UL 60947-4-1;CSA - C22.2 No. 60947-4-1-14; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking
CSA File No. E36332
CSA Class No. NLRV
North America Certification 12528
Specially designed for North America 3211-05
Suitable for UL listed, CSA certified
Degree of Protection Yes, with an alternative front plate and/or terminal markings to those of the IEC type in combination with "+NA" (105864)